• No results found

University of Groningen Towards an optimal clinical protocol for the treatment of moving targets with pencil beam scanned proton therapy Ribeiro, Cássia O.

N/A
N/A
Protected

Academic year: 2021

Share "University of Groningen Towards an optimal clinical protocol for the treatment of moving targets with pencil beam scanned proton therapy Ribeiro, Cássia O."

Copied!
2
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

University of Groningen

Towards an optimal clinical protocol for the treatment of moving targets with pencil beam

scanned proton therapy

Ribeiro, Cássia O.

DOI:

10.33612/diss.126443635

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from

it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date:

2020

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

Ribeiro, C. O. (2020). Towards an optimal clinical protocol for the treatment of moving targets with pencil

beam scanned proton therapy. University of Groningen. https://doi.org/10.33612/diss.126443635

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

Stellingen behorend bij het proefschrift

TOWARDS AN OPTIMAL CLINICAL PROTOCOL

FOR THE TREATMENT OF MOVING TARGETS

WITH PENCIL BEAM SCANNED

PROTON THERAPY

1. The use of multiple deformable image registration algorithms is a valuable strategy to reduce the uncertainty for inter- fractional dosimetric evaluation during lung cancer proton treatment. (This thesis)

2. Dosimetric errors induced by deformable image registration indicate the necessity to interpret individual 4D dose distri-butions for pencil beam scanned proton plans ideally with an error bar. (This thesis)

3. The establishment of optimal clinical protocols requires com-prehensive 4D evaluations of pencil beam scanned proton therapy for moving targets. (This thesis)

4. Although 3D robust optimised proton planning proved to be sufficient for most thoracic indications, accurate patient posi-tioning and adapting to anatomical variations over the course of treatment remain compulsory. (This thesis)

5. Clinically acceptable robust plans can be achieved for moving targets treated with Proteus®Plus, as well as with Proteus®One

proton scanning technologies. (This thesis)

6. Uncertainties in treating moving targets with protons are in-evitable. We need to know how to deal with them.

7. Intelligence is the ability to adapt to change. (Stephen Hawking) 8. A man is a success if he gets up in the morning and goes to

bed at night, and in between he does what he wants to do. (Bob Dylan)

9. It’s not the years in your life that count. It’s the life in your years. (Abraham Lincoln)

10. Happiness is not something readymade. It comes from your own actions. (Dalai Lama)

Referenties

GERELATEERDE DOCUMENTEN

Chapter 5 Evaluation of intrinsic ‘rescanning’ (pulsed beam) versus scaled rescanning (continuous beam) for the treatment of moving targets with pencil beam scanned proton

For IMPT, the planning target volume (PTV) concept of photon therapy can be replaced by a clinical target volume (CTV) robust optimisation technique, which incorporates setup

The voxel-wise worst-case dose distributions obtained from the 4DREM were used to assess the robustness of 3D and 4D robust optimised IMPT treatment plans of a lung and

For a well- hosen dilation matrix and interpolatory renement mask, we nd that the asso iated as ade algorithm preserves ertain properties of the initial fun tions, allowing us to

slaapkwaliteit bij de baseline van invloed is op de objectieve uitkomstmaten van slaap (SOL,.. WASO, TST en SE gemeten door actigrafie) over de behandeling voor de condities

Hoewel de mate van centralisatie, advertorial of reguliere advertentie, geen invloed blijkt te hebben op de betrokkenheid bij Instagram, blijkt deze wel invloed uit te oefenen op

For clinical implementation of 12 N-based range verification in pencil beam scanned delivery of proton therapy, it is highly desirable to monitor the range with ≤2 mm

Het gerechtshof is van mening dat een beding waarbij de bevoegdheid de door de verzekeringsnemer verschuldigde kosten te berekenen en vast te stellen wordt