University of Groningen

The necessity of 4D-motion monitoring for thoracic tumors treated with pencil beam scanning proton therapy

den Otter, Lydia; Anakotta, Melissa; Dieters, Margiet; Muijs, Christina T; Both, Stefan; Langendijk, J.A.; Knopf, Antje

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date: 2018

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

den Otter, L., Anakotta, M., Dieters, M., Muijs, C. T., Both, S., Langendijk, J. A., & Knopf, A. (2018). The necessity of 4D-motion monitoring for thoracic tumors treated with pencil beam scanning proton therapy: a comprehensive 4D-imaging study. Poster session presented at 57th Particle Therapy Co-Operative Group (PTCOG) meeting, Cincinatti, United States.

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

Figure 1 shows the 3D-vector motion amplitudes for the twenty patients. A median initial tumor motion was observed of 1.3 mm

(range: 0.0 – 7.4 mm). Four patients showed a motion amplitude

beyond 5 mm during the course of treatment. 7 out of 20 patients showed motion variation of more than 3 mm compared to the motion measured in week 0. Figure 2 visualizes two coronal fusion views of patients with smaller and larger motion variation. The median initial

GTV volume was 28.7 cm3 (range 1.0 – 430.0 cm3). During treatment

GTV volumes of 16 out of 19 patients shrunk with a median decrease of 39% (range: 10.8%- 63.7%), and a median absolute volume

change of 8.3 cm3 (range: 0.5-105.9 cm3).

Figure 3 shows that motion amplitudes extracted from weekly 4DCTs were not predictive for motion amplitudes extracted from daily 4DCBCTs for patients number 14. This patient showed larger motion amplitudes with a maximum weekly variation of 6.8 mm. Motion amplitudes measured by 4DCBCTs showed a daily variation up to 11.2 mm.

We are currently extending the presented data for a weekly motion analysis in 40, and a daily motion analysis in 10 lung patient cases. For pencil beam scanning intensity modulated proton therapy

(IMPT) moving targets remain challenging. The time structure of PBS-IMPT makes the treatment of moving tumours challenging due to the interplay effect. Even when using motion mitigation strategies, one needs to be aware of motion variations. Therefore, we investigated weekly and daily inter-fraction motion variations to define the most optimal motion monitoring protocol for PBS-IMPT treatments of non-small-cell lung cancer ([N]SCLC) patients.

The necessity of 4D-motion monitoring for thoracic tumors

treated with pencil beam scanning proton therapy:

a comprehensive 4D-imaging study

L.A. den Otter*, R.M. Anakotta*, M. Dieters*, C.T. Muijs*, N.M. Sijtsema*, S. Both*, J.A. Langendijk*,

A.C. Knopf*

*University of Groningen, University Medical Center Groningen, Radiation Oncology, Groningen, The Netherlands

PURPOSE

RESULTS

INTRODUCTION

To define the most optimal motion monitoring protocol for

PBS-IMPT treatments of (N)SCLC cancer patients by

investigating weekly and daily motion variations.

CONCLUSION

For a considerable part of the patients, the motion measured in week 0 based on weekly repeat 4DCT imaging was not predictive

for motion in the following weeks. Daily motion measured by 4DCBCT imaging for one patient suggests that weekly measured

4DCT motion is not predictive for the daily motion in between the weekly 4DCTs. This indicates that breathing motion differs from

day to day and daily 4D-imaging is therefore needed to assure safe PBS-PT treatments for lung cancer patients.

l.a.den.otter@umcg.nl

MATERIALS & METHODS

For 20 (N)SCLC patients (12 male, 8 female, age: 47-89, stage II-IV) 4DCT imaging was performed during pre-treatment simulation (week 0). In addition, weekly 4DCT imaging was performed during the treatment course of five weeks (week 1-5). This is to monitor anatomical changes and differences in motion. Gross tumor volumes (GTVs) were delineated on the maximum inspiration and expiration 4DCT phases. For each weekly delineated GTV, the centroid was calculated and centroid 3D-vector translations were evaluated accordingly.

For one patient, daily 3D-vector centroid 4DCBCT motion was evaluated additionally. This was also done by delineating the GTV on the maximum inspiration and expiration 4DCBCT phases, calculating the centroid positions and evaluating the centroid 3D-vector translations.

Figure 1: GTV-motion variations for 20 (N)SCLC patients extracted from weekly 4DCTs.

Figure 3: GTV-motion variations for patient 14 extracted from weekly 4DCTs and daily 4DCBCTs. 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 GTV 3D -vec tor motion (mm) Patient nr. week 1-5 week 0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0

0

5

10

15

20

25

30

35

40

45

GTV 3D0v ect or motion (mm)

Nr. of days since pre-treatment simulation

Patient 14 4DCBCT 4DCT

Figure 2: Coronal fusion views of patient’s GTVs at maximum inspiration and expiration phases. One patient showed little tumor motion variation and the second patient showed larger motion variation.

Referenties

GERELATEERDE DOCUMENTEN

Chapter 5 Evaluation of intrinsic ‘rescanning’ (pulsed beam) versus scaled rescanning (continuous beam) for the treatment of moving targets with pencil beam scanned proton

For IMPT, the planning target volume (PTV) concept of photon therapy can be replaced by a clinical target volume (CTV) robust optimisation technique, which incorporates setup

The voxel-wise worst-case dose distributions obtained from the 4DREM were used to assess the robustness of 3D and 4D robust optimised IMPT treatment plans of a lung and

Towards an optimal clinical protocol for the treatment of moving targets with pencil beam scanned proton therapy.. Ribeiro,

slaapkwaliteit bij de baseline van invloed is op de objectieve uitkomstmaten van slaap (SOL,.. WASO, TST en SE gemeten door actigrafie) over de behandeling voor de condities

Hoewel de mate van centralisatie, advertorial of reguliere advertentie, geen invloed blijkt te hebben op de betrokkenheid bij Instagram, blijkt deze wel invloed uit te oefenen op

De herhaalde curatieve toepassing op compost en dekgrond van de deze entompathogene schimmel geeft in een LNV-project een vergelijkbare reductie van het aantal champignonvliegen..

For the challenging issue to correct the measured drag values, at least the missing integration surface due to the opening for the sting seems to be correctable: Since