Edition 2022 Feb. 28

Linear DC-Servomotors

with Analog Hall Sensors

3,6 N

LM 1247 ... 11

Values at 22°C LM 1247 ... 11

Continuous force Fe max. 3,6 N

Peak force Fp max. 10,5 N

Continuous current Ie max. 0,55 A

Peak current Ip max. 1,64 A

Back-EMF constant kE 5,25 V/m/s

Force constant kF 6,43 N/A

Terminal resistance, phase-phase R 13,17 Ω

Terminal inductance, phase-phase L 820 µH

Thermal resistance Rth1 /Rth2 3,2 / 20 K/W

Thermal time constant

τ

w1 /

τ

w2 11 / 624 s

Operating temperature range -20 … +125 °C

Magnetic pitch

τ

m 18 mm

Rod bearings polymer sleeves

Housing material metal, non-magnetic

Direction of movement electronically reversible

LM 1247- 020-11 040-11 060-11 080-11 100-11 120-11

Stroke length S max. 20 40 60 80 100 120 mm

Repeatability

σ

r 40 40 40 40 40 40 µm

Accuracy

σ

a 120 140 160 180 200 220 µm

Acceleration ae max. 187,6 142,5 122,9 101,8 91,4 81 m/s²

Speed ve max. 1,9 2,4 2,7 2,9 3 3,1 m/s

Rod length L1 82 109 127 154 172 190 mm

Rod mass mm 19 25 29 35 39 44 g

Total mass mt 58 64 68 74 78 83 g

Motor characteristic curves

0,1 0,2 0,3 0,4 0,5 0,6

0 0,7 0,8 0,9 1,0

0,25 0 0,75 0,50 1,00 1,25 1,50 1,75 2,00

LM 1247–020–11

0,5 1,5 1,0 2,0 2,5 3,0 3,5 4,0 Trapezoidal motion profile (t1 = t2 = t3)

Displacement distance: 20 mm Friction coefficient: 0,2

Slope angle: 0°

Rest time: 0,1 s

Load:

The max. applicable load (incl. rod) at a given speed with an external force of 0 N External force:

The max. permissible external force at a given speed with a load (incl. rod) of:

- 0,1 kg - 0,2 kg

- 0,5 kg Speed [m/s]

External force [N]

Load (incl.rod) [kg]

Note: These motors are for operation with DC-voltage < 75 V DC. The given values are for free standing motors.

Other rod lengths available on request.

For notes on technical data and lifetime performance

refer to “Technical Information”. © DR. FRITZ FAULHABER GMBH & CO. KG

Specifications subject to change without notice.

www.faulhaber.com

(2)

Edition 2022 Feb. 28 Dimensional drawing

4x M1,6 2

43,5-0,10

9,2-0,10

000000

LM 1247 ... 11

000000

(ø6,31)

46,8

1,3 1,3

ø12,4

-0,050

12,5-0,050

19,1 6,6

L1 ±0,5

M2 3 M2 3

261±15 1

10

deep,

non-magnetic screws recommended

deep deep

Rod batch code

Option, cable and connection information

-11C

-01

1

2 109

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10 LM1247-020-11

Option Type Description

Connector

Material PVC, 10 conductors, AWG 28.

Recommended connector: Molex - Nr. 51110-1060

Material PVC, 10 conductors, AWG 28 with connector A05a - TCO, pitch 2 mm

Function No. Function Color Phase C

Phase B Phase A GND UDD (+5V) Hall sensor C Hall sensor B Hall sensor A

yellow green red black blue grey orange brown No.

N.C.

N.C.

Phase C Hall sensor A UDD (+5V)

Hall sensor C Hall sensor B

Phase A N.C.

N.C.

Phase B GND

white purple Standard cable

Material PVC, 10 conductors, AWG 28, grid 1mm, wires tinned.

Single wires

Example product designation: Connection

-11/-11C -01

Product combination

Drive Electronics Cables / Accessories MCLM 3002 P

MCLM 3002 S MCLM 3003 P MCLM 3006 S MC 3001 B MC 3001 P MC 5004 P MC 5005 S

To view our large range of accessory parts, please refer to the

“Accessories” chapter.

For notes on technical data and lifetime performance

refer to “Technical Information”. © DR. FRITZ FAULHABER GMBH & CO. KG

Specifications subject to change without notice.

www.faulhaber.com

Referenties

GERELATEERDE DOCUMENTEN

T = #BJs does not work as well as the k-fold cross-validation estimate [44] and is also not differentiable, which makes it less relevant for gradient based approaches

We investigate the link between financing and seven investment characteristics: whether the investment has high collateral value, with I(Tangible &amp; Non-unique) being a

The previous section already described that there is a relation between the perceived similarities between the new and the old system and the coping method.

A decade after the return of peace to Timor-Leste, none of the four sectors that constitute social well-being access to and delivery of education, right of return and resettlement

Chapter 4 covers the second sub-question: “What role and powers does the international community have in Bosnia’s political life and how does this influence the degree of

The central goal of the present study is to provide insight into the ways in which external experts are involved in crisis decision-making, and which anticipated

Contralateral tumors in invasive breast cancers Patients who underwent breast MRI were almost four times more frequently diagnosed with contralateral breast cancer (Table 2 ),

Background: Community Health Workers (CHWs) play a meaningful role in rendering of Maternal, Child and Women’s Health (MCWH) in South Africa.. CHWs attended training