• No results found

University of Groningen Real-time positron emission tomography for range verification of particle radiotherapy Ozoemelam, Ikechi

N/A
N/A
Protected

Academic year: 2021

Share "University of Groningen Real-time positron emission tomography for range verification of particle radiotherapy Ozoemelam, Ikechi"

Copied!
3
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

University of Groningen

Real-time positron emission tomography for range verification of particle radiotherapy

Ozoemelam, Ikechi

DOI:

10.33612/diss.133158935

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date: 2020

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

Ozoemelam, I. (2020). Real-time positron emission tomography for range verification of particle radiotherapy. University of Groningen. https://doi.org/10.33612/diss.133158935

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

147

About the Authour

Ikechi Samuel Ozoemelam was born on the 11th of January 1988 in Lagos, Nigeria. He

obtained a B.Sc degree in medical radiography and radiological sciences from the University of Nigeria in 2010. As an undergraduate student, he developed a keen interest in radiation physics and applications in cancer therapy and medical imaging. After a 3-year work period in hospitals in Nigeria and teaching/research engagement at the university of Nigeria, he relocated to Germany where he completed a masters degree in Nuclear Applications with a specialization in Medical Physics in August, 2016 at the university of applied sciences, Aachen. He also obtained a second masters degree in “Functional Imaging, Conventional and Ion Radiotherapy” from the university of applied sciences, wiener Neustadt in June 2017. While in Germany, he completed a year-long internship/master thesis in the applied physics group of the Varian Medical Systems Particle Therapy GmBH, Troisdorf. Since October, 2016, he has been working on his PhD research in the medical physics group at the KVI-Center for advanced radiation technology of the university of Groningen under the supervision of Dr. Peter Dendooven and Prof. Sytze Brandenburg. The results of his PhD research are presented in this thesis.

(3)

Referenties

GERELATEERDE DOCUMENTEN

1.1 Rationale for particle therapy Despite the application of these modern treatment techniques and the ensuing conformal high dose distributions, there is still a

Parodi K, Paganetti H, Shih H A, Michaud S, Loeffler J S, DeLaney T F, Liebsch N J, Munzenrider J E, Fischman A J, Knopf A and Bortfeld T 2007 Patient Study of in Vivo Verification

The number of decays of positron emitting nuclides integrated from the start of an irradiation as a function of time during the irradiation, for irradiation with 59 MeV/u 3 He

The in vivo verification technique relying on the in-beam PET imaging of very short-lived positron emitters such as 12 N (T 1/2 = 11 ms), recently proposed and

For clinical implementation of 12 N-based range verification in pencil beam scanned delivery of proton therapy, it is highly desirable to monitor the range with ≤2 mm

In this thesis, a study of the production of suitable very short-lived positron emitters for in vivo range verification of helium beam radiotherapy and

Real-time positron emission tomography for range verification of particle radiotherapy Ozoemelam,

In dit proefschrift worden studies gepresenteerd over de productie van geschikte zeer kortlevende positronemitters voor in vivo drachtverificatie van radiotherapie