University of Groningen Real-time positron emission tomography for range verification of particle radiotherapy Ozoemelam, Ikechi

N/A
N/A
Protected

Academic year: 2021

Share "University of Groningen Real-time positron emission tomography for range verification of particle radiotherapy Ozoemelam, Ikechi"

Copied!
3
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

University of Groningen

Real-time positron emission tomography for range verification of particle radiotherapy

Ozoemelam, Ikechi

DOI:

10.33612/diss.133158935

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from

it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date:

2020

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

Ozoemelam, I. (2020). Real-time positron emission tomography for range verification of particle

radiotherapy. University of Groningen. https://doi.org/10.33612/diss.133158935

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

137

List of Publications

Published

Ozoemelam I S, van der Graaf E R, Brandenburg S, Dendooven P. The production of

positron emitters with millisecond half-life during helium beam radiotherapy.

Physics in

Medicine and Biology (2019) 64:235012.

https://doi.org/10.1088/1361-6560/ab51c3

Ozoemelam I S, van der Graaf E R, van Goethem M-J, Kapusta M, Zhang N,

Brandenburg S, Dendooven P. Phys. Med. Biol.. Feasibility of Quasi-prompt PET-based

range verification in proton therapy.

https://doi.org/10.1088/1361-6560/aba504

Submitted

Ozoemelam I S, van der Graaf E R, van Goethem M-J, Kapusta M, Zhang N,

Brandenburg S, Dendooven P. Real-Time PET imaging for range verification of helium

radiotherapy.

(3)

Referenties

GERELATEERDE DOCUMENTEN

Global total lesion glycolysis and global metabolic volume are better metabolic indices for measuring infections associated with immune dysfunction compared to standardized

Real-time positron emission tomography for range verification of particle radiotherapy Ozoemelam,

1.1 Rationale for particle therapy Despite the application of these modern treatment techniques and the ensuing conformal high dose distributions, there is still a

Parodi K, Paganetti H, Shih H A, Michaud S, Loeffler J S, DeLaney T F, Liebsch N J, Munzenrider J E, Fischman A J, Knopf A and Bortfeld T 2007 Patient Study of in Vivo Verification

The number of decays of positron emitting nuclides integrated from the start of an irradiation as a function of time during the irradiation, for irradiation with 59 MeV/u 3 He

The in vivo verification technique relying on the in-beam PET imaging of very short-lived positron emitters such as 12 N (T 1/2 = 11 ms), recently proposed and

For clinical implementation of 12 N-based range verification in pencil beam scanned delivery of proton therapy, it is highly desirable to monitor the range with ≤2 mm

In this thesis, a study of the production of suitable very short-lived positron emitters for in vivo range verification of helium beam radiotherapy and