GAIT ANALYSIS USING ULTRASOUND AND INERTIAL SENSORS

Dirk Weenk*, Fokke B. van Meulen, Bert-Jan J. F. van Beijnum, Ed Droog, Daniel Roetenberg, Hermie J. Hermens and Peter H. Veltink

*University of Twente, Faculty of EEMCS, Biomedical Signals and Systems P.O. Box 217, 7511 AE Enschede, the Netherlands

e-mail: D.Weenk@utwente.nl Web page: http://www.utwente.nl/ewi/bss

ABSTRACT

Introduction and past research: Inertial sensors are great for orientation estimation, but they cannot measure relative positions of human body segments directly. In previous work we used ultrasound to estimate distances between body segments [1]. In [2] we presented an easy to use system for gait analysis in clinical practice but also in-home situations. Ultrasound range estimates were fused with data from foot-mounted inertial sensors, using an extended Kalman filter, for 3D (relative) position and orientation estimation of the feet.

Validation: From estimated 3D positions we calculated step lengths and stride widths and compared this to an optical reference system for validation. Mean (±standard deviation) of absolute differences was 1.7 cm (±1.8 cm) for step lengths and 1.2 cm (±1.2 cm) for stride widths when comparing 54 walking trials of three healthy subjects.

Clinical application: Next, the system presented in [2] was used in the INTERACTION project, for measuring eight stroke subjects during a 10 m walk test [3]. Step lengths, stride widths and stance and swing times were compared with the Berg balance scale score. The first results showed a correlation between step lengths and Berg balance scale scores. To draw real conclusions, more patients and also different activities will be investigated next.

Future work: In future work we will extend the system with inertial sensors on the upper- and lower legs and the pelvis, to be able to calculate a closed loop and improve the estimation of joint angles compared with systems containing only inertial sensors.

REFERENCES

[1] D. Weenk, B. J. F. van Beijnum, A. Droog, H. J. Hermens, and P. H. Veltink, “Ultrasonic range measurements on the human body”, in Seventh International Conference on Sensing Technology, ICST 2013, Wellington, New Zealand. IEEE, December 2013, pp. 151–156. http://dx.doi.org/10.1109/ICSensT.2013.6727633.

[2] D. Weenk, D. Roetenberg, B. J. F. van Beijnum, H. J. Hermens, and P. H. Veltink, “Ambulatory Estimation of Relative Foot Positions by Fusing Ultrasound and Inertial Sensor Data”, IEEE Transaction On Neural Systems And Rehabilitation Engineering, In press, 2014. http://dx.doi.org/10.1109/TNSRE.2014.2357686

[3] D. Weenk, F. B. van Meulen, B. J. F. van Beijnum, and P. H. Veltink, “Ambulatory gait analysis in stroke patients using ultrasound and inertial sensors”, In: 13th International Symposium on 3D Analysis of Human Movement, 3D-AHM 2014, 14-17 July 2014, Lausanne, Switserland. pp. 385-388. EPFL. ISBN 9782880748562

Referenties

GERELATEERDE DOCUMENTEN

Deze vraag zal beantwoord worden door eerst grandioos en kwetsbaar narcisme uitgebreid te beschrijven en te vergelijken, waarna gekeken wordt of het verschil tussen deze twee

We have found that depending on the transparency of the SIs tunnel barrier, the decrease in the s-layer thickness leads to transformation of the CPR shape going in the two

The Western Cape Education Language Act (Western Cape Province, 1998) recognises three official languages, namely English, Afrikaans and isiXhosa that can be used as a lan­ guage

Since this experiment was done in the context of inquiry learning, the reasoning of children might give us some interesting insights in what they have learned from the experiment

When leverage is defined as book leverage or market leverage firm size has a significant positive effect, which is in line with the agency theories and the trade-off

derived from the theoretical application of the case study of the interaction between Europol and volunteers in the ‘Save a Child – Trace an Object’ project to the governance model of

Once the EU’s traditional stakeholders of the smart grid were identified, it allowed to identify emerging actors within the smart grid ecosystem and that were related to GET as well

Such an approach would, for any particular blood matching strategy, allow balancing the costs of donor recruitment, donor typing, inventory management, blood product logistics,