RESEARCH ARTICLE
Detection of extracellular vesicles in plasma
and urine of prostate cancer patients by flow
cytometry and surface plasmon resonance
imaging
Linda G. RikkertID1,2,3☯*, Leonie de Rond2,3,4☯, Annemieke van Dam4, Ton G. van
Leeuwen3,4, Frank A. W. Coumans2,3, Theo M. de Reijke5, Leon W. M. M. Terstappen1, Rienk Nieuwland2,3
1 Department of Medical Cell BioPhysics, University of Twente, Enschede, The Netherlands, 2 Laboratory of
Experimental Clinical Chemistry, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands,
3 Vesicle Observation Center, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands, 4 Biomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, The
Netherlands, 5 Department of Urology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
☯These authors contributed equally to this work.
*l.g.rikkert@amsterdamumc.nl
Abstract
Large (>1μm) tumor-derived extracellular vesicles (tdEVs) enriched from the cell fraction of centrifuged whole blood are prognostic in metastatic castration-resistant prostate cancer (mCRPC) patients. However, the highest concentration of tdEVs is expected in the cell-free plasma fraction. In this pilot study, we determine whether mCRPC patients can be discrimi-nated from healthy controls based on detection of tdEVs (<1μm, EpCAM+) and/or other EVs, in cell-free plasma and/or urine. The presence of marker+ EVs in plasma and urine samples from mCRPC patients (n = 5) and healthy controls (n = 5) was determined by flow cytometry (FCM) and surface plasmon resonance imaging (SPRi) using an antibody panel and lactadherin. For FCM, the concentrations of marker positive (+) particles and EVs (refractive index<1.42) were determined. Only the lactadherin+particle and EV concentra-tion in plasma measured by FCM differed significantly between patients and controls (p = 0.017). All other markers did not result in signals exceeding the background on both FCM and SPRi, or did not differ significantly between patients and controls. In conclusion, no dif-ference was found between patients and controls based on the detection of tdEVs. For FCM, the measured sample volumes are too small to detect tdEVs. For SPRi, the concen-tration of tdEVs is probably too low to be detected. Thus, to detect tdEVs in cell-free plasma and/or urine, EV enrichment and/or concentration is required. Furthermore, we recommend testing other markers and/or a combination of markers to discriminate mCRPC patients from healthy controls.
a1111111111 a1111111111 a1111111111 a1111111111 a1111111111 OPEN ACCESS
Citation: Rikkert LG, de Rond L, van Dam A, van
Leeuwen TG, Coumans FAW, de Reijke TM, et al. (2020) Detection of extracellular vesicles in plasma and urine of prostate cancer patients by flow cytometry and surface plasmon resonance imaging. PLoS ONE 15(6): e0233443.https://doi. org/10.1371/journal.pone.0233443
Editor: Jeffrey Chalmers, The Ohio State University,
UNITED STATES
Received: November 13, 2019 Accepted: May 5, 2020 Published: June 4, 2020
Copyright:© 2020 Rikkert et al. This is an open access article distributed under the terms of the
Creative Commons Attribution License, which
permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability Statement: All FCM and SPRi
files are available from FlowRepository (Repository ID: FR-FCM-Z2CC).
Funding: This work was supported by the
Netherlands Organisation for Scientific Research – Domain Applied and Engineering Sciences (NWO-TTW), under research programs Perspectief CANCER-ID 14198 (LR), Perspectief CANCER-ID 14195 (LdR), and VENI 13681 (FC). The funder had no role in study design, data collection and
Introduction
Circulating tumor cells (CTCs) and large (> 1μm) tumor-derived extracellular vesicles
(tdEVs) measured with the CellSearch are both associated with poor survival of metastatic cas-tration-resistant prostate cancer (mCRPC) patients [1–4]. Furthermore, changes in concentra-tions of CTCs and tdEVs after initiation of therapy can be used to monitor treatment
response. CellSearch identifies CTCs and large tdEVs in thecell fraction of centrifuged whole
blood by using EpCAM immunomagnetic enrichment combined with immunofluorescence labeling, and defines both by cytokeratin expression and lacking the leukocyte marker CD45. Discrimination between CTCs and tdEVs is obtained by cell morphology features, and the presence of a nucleus in case of CTCs. For mCRPC patients, a median of ~7 CTCs and ~116 large tdEVs per 7.5 mL of blood was reported (i.e. ~0.009 CTCs and ~0.015 large tdEVs
perμL) [1]. As the EV concentration increases with decreasing size [5], a 100–1,000 fold higher
concentration of small (< 1μm) tdEVs is expected in blood of mCRPC patients, resulting in
an expected concentration of ~1.5–15 small tdEVs per uL blood. The majority of small tdEVs
should be present incell-free plasma of mCRPC patients [6], and may directly be measured in
plasma without enrichment techniques. In this study, we performed a pilot study to determine whether mCRPC patients can be discriminated from healthy controls based on the presence of
small tdEVs (< 1μm, EpCAM+
) and other EV subtypes, directly in cell-free plasma and/or
urine. Since EVs <1μm are below the detection limit of the CellSearch Analyzer, we used flow
cytometry (FCM) and surface plasmon resonance imaging (SPRi) in this study.
Methods
Minimal detectable marker
+particle concentration for FCM
To determine the minimal detectable marker+particle concentration for FCM, we performed
a spiking experiment (S1 File). Conditioned medium containing Cell-derived EVs (PC3 cells), identified by CD63-PE, was mixed with plasma at different volumetric dilutions. The minimal
detectable marker+particle concentration was defined as the concentration at which the
num-ber of detected CD63+particles exceeded the 95% confidence interval based on pure plasma.
Sample collection
Blood and urine were obtained from five mCRPC patients and five healthy male controls. See Table 1for donor characteristics. Samples were collected with written informed consent in accordance with the Helsinki Declaration and approved by the medical-ethical assessment committee of the Academic Medical Center, University of Amsterdam (NL64623.018.18). For each donor, whole blood was collected using a 21G needle, and the first vacutainer was Table 1. Metastasized castration-resistant prostate cancer (mCRPC) patients and healthy controls characteristics. Variable mCRPC patients (n = 5) Healthy controls (n = 5)
Age in years, mean (range) 80 (66–83) 28 (19–40)
Ethnicity Caucasian Caucasian
Mean (range) serum PSA level (ng/mL)� 6.0 (0.1–17.6) NA
Mean (range) total Gleason score (biopsy tissue) 7.8 (6–9) NA
Previous treatment for prostate cancer�� Yes NA
mCRPC: metastasized castration-resistant prostate cancer; NA: not applicable; PSA: prostate specific antigen �last determined PSA level before inclusion
��including surgery, hormone therapy, radiotherapy, cryotherapy, and/or chemotherapy. https://doi.org/10.1371/journal.pone.0233443.t001
analysis, decision to publish, or preparation of the manuscript.
Competing interests: I have read the journal’s
policy and the authors of this manuscript have the following competing interests: Frank Coumans is majority shareholder in Exometry, Amsterdam, The Netherlands. This does not alter our adherence to PLOS ONE policies on sharing data and materials.
Abbreviations: CTCs, Circulating tumor cells; EVs,
Extracellular vesicles; FCM, Flow cytometry; mCRPC, Metastasized castration-resistant prostate cancer; PBS, Phosphate buffered saline; SPRi, Surface plasmon resonance imaging; tdEVs, Tumor-derived extracellular vesicles.
discarded. Next, three 2.7 mL citrate vacutainers (BD Biosciences, San Jose, CA) were col-lected, mixed by gentle inversion and processed within 20 minutes. Vacutainers were
centri-fuged at 2,500g, 20˚C for 15 minutes without brake in a Rotina 380R centrifuge (Hettich,
Tuttlingen, Germany). Plasma was collected until approximately 0.5 cm above the pellet using a 5 mL Pasteur pipet (VWR, Radnor, PA). The plasma was pooled and transferred to a conical
base tube (10 mL; Sarstedt, Nu¨mbrecht, Germany), and centrifuged at 2,500g, 20˚C for 15
minutes. The supernatant was transferred to a conical base tube and divided over 75μL
cryo-vials (Sarstedt), followed by snap-freezing in liquid nitrogen and storage at -80˚C.
First catch-urine (no prostate massage) was collected in 125 mL routine urine collection cups free of any preservatives. Urine samples were placed on melting ice (0˚C) and transported to the laboratory within one hour after collection. The urine collection cup was inverted five times to resuspend the cells. To remove the cells, two aliquots of 20 mL urine were centrifuged
at 500g, 4˚C for 20 minutes without a brake using a Rotina 46RS centrifuge (Hettich). The
supernatant was pooled, vortexed for at least 10 s and aliquots of 1 mL were pipetted in cryo-vials (Sarstedt), followed by snap-freezing in liquid nitrogen and stored at -80˚C.
Sample preparation
All samples were thawed in a 37˚C water bath. For the FCM measurements, the urine samples showed a high level of autofluorescence in the FITC channel, which disappeared after size
exclusion chromatography (SEC). Therefore, for each urine sample, 150μL of urine was
loaded on SEC columns (qEVsingle/70 nm; Izon Science, Christchurch, New Zealand), fol-lowed by elution with phosphate buffered saline (PBS; 21-031-CV; Corning, Corning, NY).
The first 1250μL eluate was discarded, and the next 500 μL eluate, containing particles with a
diameter larger than 70 nm, was used for the FCM measurements. In preliminary experiments, undiluted urine samples caused negative SPRi responses, which disappeared after 5-fold dilu-tion in PBS. Therefore, all samples were pre-diluted 5-fold in PBS for SPRi.
Markers
A panel of fourteen markers was selected. We included lactadherin, CD9, CD63 and CD81
which are associated with EVs [7,8], CD45 expressed by leukocytes, CD61 expressed by
plate-lets, CD146 expressed by endothelial cells and CD235a expressed by erythrocytes. In addition, we included EpCAM expressed on cells of epithelial cell origin [1], PSMA expressed on pros-tate cells [9] or markers reported to be overexpressed on cancer cells CD24, CD47, CD142,
HER2 [10–13], and an isotype control. An overview is shown inTable 2.
In FCM, the PE-conjugated isotype control resulted in PE positive concentrations higher than the PE positive concentration found for the actual markers. The PE-conjugated isotype control was considered unreliable, and measurements of marker in PBS were used to estimate the background.
Samples were measured simultaneously by FCM and SPRi, alternating between samples from patients and controls, followed by PBS samples.
Flow cytometry
Plasma samples were pre-diluted in PBS to event rates between 2,000 and 3,000/s to prevent swarm detection when triggering on side scatter [14]. The pre-dilution varied per plasma sam-ple, and ranged between 10-fold to 100-fold dilution. The urine samples were diluted by SEC, and no additional dilution was necessary to prevent swarm detection. Antibody aggregates
were removed by centrifugation at 18,890g, 20˚C for 5 minutes prior to use. 20 μL of
hours at room temperature in the dark. The staining was stopped by adding 200μL PBS. All
samples were analyzed on an A60-Micro (Apogee; Northwood, UK) at a flow rate of 3.0μL/
minute. Each sample was measured for four minutes or until 500,000 events were detected, triggering on 405-nm side scatter using a threshold corresponding to a side scattering cross
section of 10 nm2(Rosetta Calibration; Exometry, Amsterdam, The Netherlands). Taking into
account the sample dilution and measurement time, a total of approximately 0.008 to 0.08μL
for plasma and 1μL SEC eluate of urine was analyzed.
Data analyses were performed in MATLAB R2018b (Mathworks, Natick, MA) and FlowJo (v10.6.1; FlowJo, Ashland, OR). First, for samples with a minimum count rate of 250 counts/s, time points of the data in which the count rate deviated >25% from the median count rate were removed to account for fluctuations in the flow rate. Next, fluorescent gates were deter-mined for every marker, resulting in the gates as mentioned in the supplemented MIFlowCyt inS1 Appendix. Positive (+) events are defined as events with a fluorescent signal exceeding
the gate. Using this conventional gating strategy, all marker+particles are taken into account,
including non-specific binding of markers to lipoproteins or protein aggregates. Recently, we
showed that marker+EVs can be distinguished from other marker+particles using the
refrac-tive index (RI) [15]. Therefore, we also determined the RI of all particles > 200 nm using Flow-SR as described previously [15]. Briefly, using the ratio of side versus forward scatter, Mie theory, and a mathematical model of the optical configuration of the flow cytometer, the diameter of each particle can be determined. The RI can subsequently be derived from a Table 2. Markers used for flow cytometry (FCM) and surface plasmon resonance imaging (SPRi).
Marker Target protein Clone Concentration (μg/mL)
Conjugate Company FCM SPRi
CD9 Tetraspanin M-L13 2.5 5 PE BD Biosciences, San Jose, CA
CD24 Sialoglycoprotein SN3 Unknown 5 PE Thermo Fisher Scientific, Waltham, MA1; eBioscience, San Diego,
CA2
CD45 Protein tyrosine phosphatase, receptor type C
HI30 50 5 FITC Biolegend, San Diego, CA1; Sony Biotechnology, San Jose, CA2
CD47 Integrin associated protein CC2C6 8 5 PE Biolegend, San Diego, CA
CD61 Integrine beta-3 VI-PL2 3 5 PE Thermo Fisher Scientific, Waltham, MA1; BD Biosciences, San Jose,
CA2
CD63 Tetraspanin H5C6 6.25 5 PE BD Biosciences, San Jose, CA1; Cell Guidance Systems, Cambridge,
UK2
CD81 Tetraspanin JS-81 5 5 PE BD Biosciences, San Jose, CA
CD235a Glycophorin A JC159 100 5 PE Agilent Technologies, Santa Clara, CA3
CD142 Tissue factor HTF-1 9 5 PE BD Biosciences, San Jose, CA1; eBioscience, San Diego, CA2
CD146 Melanoma cell adhesion molecule P1H12 12.5 5 FITC Sony Biotechnology, San Jose, CA1; eBioscience, San Diego, CA2
EpCAM Epithelial cell adhesion molecule VU1D9 6 5 PE Thermo Fisher Scientific, Waltham, MA1; Own hybridoma cell line, Enschede, Netherlands3
HER2 Erb-b2 receptor tyrosine kinase 2 24D2 25 5 PE Biolegend, San Diego, CA
Lactadherin Milk fat globule-EGF factor 8 NA 41.5 5 FITC Haematologic Technologies, Essex Junction, VT3
PSMA Glutamate carboxypeptidase II REA408 11 5 PE Miltenyi Biotec, Bergisch Gladback, Germany
IgG1 Immunoglobuline G X40 50 5 FITC/PE BD Biosciences, San Jose, CA
FITC: fluorescein isothiocyanate; NA: not applicable; PE: phycoerythrin
1FCM 2SPRi
3Same conjugated antibody used for FCM and SPRi.
lookup table of side scatter versus diameter. In the present study, marker+particles include all
particles above the size detection limit (Table 3) and positive for a marker, whereas marker+
EVs include particles > 200 nm with an RI < 1.42 and positive for a marker.
Concentrations provided are the number of detected events corrected for the total sample dilution, flow rate and measurement time. Because for urine, the dilution caused by SEC was
unknown, the marker+concentration is expressed as marker+particles/EVs perμL SEC eluate.
For a detailed description of the flow cytometer configuration, operating conditions and data
analysis please see the supplemented MIFlowCyt list inS1 Appendix.
Surface plasmon resonance imaging
SPRi measurements were performed using the MX96 SPRi device (IBIS technologies B.V.,
Enschede, the Netherlands) as described by Stravers et al. [17]. Markers (5μg/mL) were
printed in triplicate on a sensor surface (Easy2Spot type-G; Ssens B.V., Enschede, The Nether-lands) using a Continuous Flow Micro-spotter (CFM) 2.0 (Wasatch microfluidics LLC, Salt Lake City, UT). Three spots were used as control spots, and active sites on the sensor surface were inactivated [17]. In total four sensors were used, each analyzing six samples, i.e. five plasma or urine samples and one negative control (PBS).
Before starting the six sample runs, three regeneration runs were applied, consisting of i) a baseline phase of two minutes, ii) an association phase of 15 minutes, whereby regeneration buffer (0.1 M Glycine (Merck, Darmstad, Germany), pH 3.06 and 0.3% (v/v) Triton-x100 (Sigma-Aldrich, Darmstadt, Germany)) is flowed back and forth over the sensor surface, and iii) a dissociation phase of two minutes, whereby the regeneration buffer is replaced by PBS.
Next, 300μL of each pre-diluted sample was placed into the SPRi to allow measurement of
each sample in duplicate. A single sample run consisted of i) a baseline phase of two minutes, ii) an association phase of 60 minutes, whereby the sample is flowed back and forth over the sensor surface and iii) a dissociation phase of four minutes. After each sample run, the chip surface was regenerated to break the formed antigen-antibody bonds before the next sample Table 3. Characteristics of the methods used for the detection of extracellular vesicles (EVs).
Flow cytometry SPRi Detection of Single EVs Ensemble EVs
EV size detection limit �160 nm� All EVs
Particle detection In suspension On surface
Signal caused by Light scattering, fluorescence Refractive index change
Minimal # EVs/μL 1x103�� 2x105[16]
Antigen detection limit 70 molecules (PE) 1
Preparation steps Sample dilution, fluorescent marker staining Sample dilution, printing markers on sensor
Preparation time 2.5 hours 2 hours
Measurement time / sample
1–4 minutes��� 1 hour
Output Antigen expression, concentration, size, refractive index
Antigen expression
�As determined using Rosetta Calibration (Exometry, Amsterdam, The Netherlands) using a core-shell model with refractive index (RI) of 1.38 for the core, 1.48 for the shell and a shell thickness of 4 mm.
��Based on the 95% confidence interval for buffer only measurements (n = 3). ���Increases with the number of markers to be analyzed.
run was started. Taking into account the sample dilution, 26μL of plasma and urine was ana-lyzed per sample run.
File conversion and analysis was performed as described by Stravers et al. [17]. SPRi signals in PBS were set to zero to account for differences in the initial spot values. The first 100 s of the association phase was removed from the analysis to account for RI differences of buffers. The mean SPRi signals of each marker of the last 50 s of the association phase, corrected for the ref-erence spot, was used as the maximum response. The diffref-erence between the maximum response and the response after 100 s of each spot was used to calculate the mean response in resonance units (RU). While three spots were printed for each marker, we included data from the two spots with the highest relative ligand density (RLL) because of printing artifacts in some spots. A data point represents the RI change during one hour per sample averaged over the two spots. To correct for degeneration of the sensor and for differences in the total particle concentration between samples, the response per sample was normalized by dividing the response for one marker by the sum of all marker responses for that sample. The mean of the duplicates was calculated to obtain a response per marker per donor.
Data analysis
Median and standard deviation (SD) of the data was calculated per marker. The median is pre-ferred over the mean, because the median is less influenced by outliers and therefore more rep-resentative given the small number of samples. Statistical analysis was performed using a Student’s t-test. All analyses were performed in MATLAB R2018b (Mathworks, Natick, MA).
Results
Minimal detectable marker
+particle concentration for FCM
Fig 1Ashows the side scatter versus CD63-PE fluorescence scatter plots for pure plasma, and
for PC3 EVs spiked in plasma at a 1:1,000 and 1:1 volumetric dilution.Fig 1Bshows that at a
volumetric dilution of 1:1,000, the number of detected CD63+particles exceeded the 95%
con-fidence interval for pure plasma. Correction for the particle concentration of the PC3 EV
sam-ple and the percentage of CD63+particles in the sample, led to a minimal detectable
concentration of 15 marker+particles/μL. Since the A60-micro FCM used in this study has a
higher scatter sensitivity and similar fluorescence sensitivity than the A50-micro used in the spiking experiment, we expect the minimal detectable concentration for the A60-micro to be
similar or lower than 15 marker+particles/μL.
Flow cytometry
Fig 2shows the marker+concentration measured by FCM in plasma (Fig 2A and 2B) and
urine (Fig 2C and 2D) of patients and controls, and in PBS.Fig 2A and 2Cshow the marker+
particle concentration obtained using conventional gating, that is including all marker+
parti-cles.Fig 2Ashows that for all markers studied, the marker+particle concentrations exceeded
the background measured in PBS (p<0.05). However, only the lactadherin+particle
concen-trations differed significantly between patients and controls (p = 0.042). The EpCAM+and
PSMA+particle concentrations were similar in plasma samples from patients and controls,
making it unlikely we detected tdEVs.
Fig 2Bshows the RI of marker+particles >200 nm in plasma of patients and controls, and
in PBS. When using the RI to identify true marker+EVs (RI<1.42) in the sample, marker+
EVs were found for all markers except for CD146, and EpCAM in controls, which did not exceed the background measured in PBS (p>0.05). EpCAM and PSMA mainly stained
particles with an RI>1.42, which most likely are lipoproteins [15]. Again, only lactadherin
showed a significant difference in the marker+EV concentration between patients and
con-trols (p = 0.017).
Marker+concentrations in urine (Fig 2C) were approximately 10-fold lower than marker+
concentrations in plasma. Marker+particles were found for lactadherin, CD9, CD63, CD81,
CD61, CD146, CD235a in patients, CD24, CD47 in patients, CD142, and HER2 in patients
(p<0.05). However, neither of these marker+concentrations differed significantly between
patients and controls. When using the RI to identify true marker+EVs in the sample,
concen-trations exceeding the background in PBS were found for all markers except for CD146, CD235a in controls, CD142 in controls, EpCAM in controls, and PSMA in patients (p>0.05). However, again none of the markers exceeding the background showed a significant difference
in the marker+EV concentration between patients and controls.
Taken together, the lactadherin+particle and EV concentration in plasma differed
signifi-cantly between patients and controls as measured by FCM. All other markers tested on plasma and urine samples that showed concentrations exceeding the background, did not show a sig-nificant difference between patients and controls.
Volumetric dilution
101
Number of detected CD63+ EVs
spiked plasma plasma 95% CI on plasma 102 103 104 10-3 10-2 10-1 100 CD63-PE 104 102 100 104 102 100 Side scatter Plasma 1:1000 1:1 CD63-PE 104 102 100 CD63-PE 104 102 100 104 102 100 Side scatter 104 102 100 Side scatter A B
Fig 1. Spiking experiment to determine the minimal detectable marker+ particle concentration for flow cytometry. A) Side scatter versus
CD63-PE fluorescence for pure plasma (left), plasma spiked with PC3 extracellular vesicles (EVs) at a 1:1000 volumetric dilution (centre) and 1:1 volumetric dilution (right). B) Detected number of CD63+particles (black dots) at volumetric dilutions of PC3 EVs in plasma. CI: confidence
interval.
Surface plasmon resonance imaging
Fig 3Ashows the normalized SPRi responses per marker as measured for plasma from patients and controls. Particles expressing lactadherin, CD63, CD81 in patients, CD61 in patients, CD146, CD24 in patients and CD47 in patients were found in plasma, since their responses exceeded the IgG response (p<0.05). However, none of these marker responses differed signif-icantly between plasma of patients and controls.
Fig 3Bshows the normalized SPRi responses per marker as measured for urine from patients and controls. Particles expressing CD235a in controls, CD47 in controls and CD142 were found, since their responses exceeded the IgG response (p<0.05). Similar as in plasma, none of these markers differed significantly between plasma of patients and controls.
0 10 20 30 40
Plasma conventional gating
0 3 10 20 Plasma RI gating Marker+ concentration (/μL) Marker Marker 15 20
25 103 Urine conventional gating
0 1 2 3 30 60 90 Urine RI gating 0 2 4 102 Marker+ concentration (/μL) 104 104 Marker CD24 CD146
CD9 CD63 CD81 CD47CD142EpCAMHER2PSMA Lact Marker A C B D CD45 CD61 CD235a 5 6 Patients Controls PBS Patients RI<1.42 RI>1.42 Controls RI<1.42 PBS RI<1.42 CD24 CD146
CD9 CD63 CD81 CD47CD142EpCAMHER2PSMA
Lact CD45 CD61 CD235a Patients Controls PBS CD24 CD146
CD9 CD63 CD81 CD47CD142EpCAMHER2PSMA
Lact CD45 CD61
CD235a Lact CD9 CD63 CD81CD45 CD61CD146CD235aCD24CD47CD142EpCAMHER2PSMA Patients RI<1.42
RI>1.42 Controls RI<1.42 PBS RI<1.42
Fig 2. Marker+concentration by flow cytometry per
μL plasma (A-B) or urine (C-D) from metastatic castration-resistant prostate cancer patients (red, n = 5), healthy controls (grey, n = 5) and phosphate buffered saline (blue, n = 2). Panels B and D show the refractive index (RI) of marker+ particles >200 nm. Data shown represent the median and standard deviation (whiskers) per group. Lact: lactadherin.
Discussion
We determined whether mCRPC patients could be discriminated from healthy controls based on the presence of EV subtypes in plasma and/or urine samples, using FCM and SPRi. FCM was chosen because FCM is frequently used to measure the concentration of EVs in clinical samples such as plasma or urine. However, the majority of common flow cytometers do not detect EVs smaller than 300 nm [18]. For example, the FCM used in this study has an EV size detection limit of 160 nm and an antigen detection limit of 70 PE molecules (Table 3). In SPRi, multiple EVs captured on a surface coated with markers induce a change in the index of refrac-tion, thereby generating the SPRi signal. All EVs, also the EVs too small to be detected by FCM, may contribute to the SPRi signal. However, since an ensemble of EVs binds to the sur-face, evaluation of the concentration of EVs is not possible with SPRi [16].
Only for the lactadherin+particle and EV concentration in plasma measured by FCM, a
signif-icant difference was found between patients and controls. Use of the RI to identify true marker+
EVs increased the specificity by exclusion of marker+lipoproteins (RI>1.42) [15]. The cause of
the significant difference in lactadherin+particle and EV concentration may be due to the
pres-ence of prostate cancer, but the influpres-ence of the age [19] and treatment differpres-ences between the groups cannot be excluded (Table 1). All other markers did not result in signals exceeding the background in PBS, or showed no significant differences between patients and controls.
Various explanations for the absence of a significant difference in small tdEVs between patients and controls are conceivable. First, no detectable differences are present in EV
sub-types <1μm in the plasma and/or urine samples of the two groups. The small EVs may be
bound to or taken up by leukocytes or endothelial cells, and thus will be absent in the cell-free plasma after centrifugation [20]. Furthermore, target proteins, like EpCAM, may be cleaved from EVs, which may restrict the capture and/or detection EVs [21].
Secondly, extrapolation of the concentration of CTCs and large tdEVs found in a previous
study [1], results in an expected small tdEV (< 1μm, EpCAM+) concentration of 1.5-15/μL in
plasma [22]. Based on our spiking experiment, we expect the minimal detectable concentration
for the A60-micro to be 15 marker+particles/μL. However, since we measured plasma
0 0.1 0.2 0.3 0.4 0.5
Normalized SPRi response
Plasma Urine A B Marker 0 0.1 0.2 0.3 0.4 0.5
Normalized SPRi response
Marker
Patients Controls
CD24 CD146
CD9 CD63CD81 CD47CD142EpCAMHER2PSMA
Lact CD45CD61
CD235a
IgG
CD24 CD146
CD9 CD63CD81 CD47CD142EpCAMHER2PSMA
Lact CD45CD61
CD235a
IgG Patients Controls
Fig 3. Surface plasmon resonance imaging (SPRi) response for plasma (A) or urine (B) of metastatic castration-resistant prostate cancer patients (red, n = 5), healthy
controls (grey, n = 5) and phosphate buffered saline (blue, n = 2) for different markers. Data shown represent the median and standard deviation (whiskers) per group. Lact: lactadherin; RU: resonance unit.
volumes < 0.1μL, it was impossible to detect the few tdEVs that might be present in the
plasma sample. For SPRi, a minimum concentration of 105marker+particles/μL is needed to
obtain a signal (Table 3). Therefore, it is likely that the concentration of tdEVs is too low to be detected with SPRi.
A third explanation is that the actual small tdEV concentration is less than the expected small tdEV concentration based on the extrapolation of CTC and large tdEV concentrations [22]. For example, the detected concentrations of small (here 160–1,000 nm) leukocyte EVs
was 9.3 x 103perμL plasma in controls. The concentration of large (> 1 μm) leukocyte EVs
was found to be ~900 perμL blood in controls [23]. Thus, the concentration of small leukocyte
EVs was not, as mentioned in the introduction, 100–1,000 fold higher than the concentration of large leukocyte EVs, but only 10-fold higher.
Another explanation is that the antigen density on small EV subtypes may be below the anti-gen detection limit for FCM. For example, the detection limit for EpCAM-PE used in this study
was 70 mean equivalent soluble fluorophore (MESF;Table 3and supplemented MIFlowCyt in
S1 Appendix). Since the dye to protein ratio of PE-conjugated antibodies is typically 1, this means that an EV should have a minimum of 70 EpCAM molecules for it to be detected as
EpCAM+, assuming the staining efficiency is 100%. If we extrapolate the measured EpCAM
den-sity on CTCs described by Rao et al. [24] to EVs with a diameter of 300 nm, the expected number of EpCAM molecules is ~40, which is below the detection limit for EpCAM in this study.
Biggs et al. [25], showed a difference in the detection of PSMA+particles between controls
and prostate cancer patients with a Gleason score higher than 8. However, the PSMA clone (3/
E7) used by this and one other study [25,26] differs from the one used in our study (REA408),
and is not commercially available. Logozzi et al. [27] detected a higher concentration of EVs expressing CD81 and PSA in blood from prostate cancer patients compared to controls. How-ever, in that study the EVs were concentrated by ultracentrifugation before measurements. In our study, the goal was to detect EVs directly in plasma and urine and therefore we did not concentrate the EVs before measurements.
To investigate whether small tdEVs are present in the plasma and/or urine of patients, we recommend to perform an enrichment or concentration enhancement step to increase the con-centration of small tdEVs. Furthermore, other clones/markers and/or a combination of markers may be needed, as used by Nanou et al. [1]. Moreover, for FCM, the development of brighter fluorophores and/or more sensitive fluorescence detectors is required to allow detection of the low number of antigens present on EVs. For SPRi, EV concentrations need to be increased to reach the minimal detectable concentration, and/or the SPRi response per EV needs to be increased. Furthermore, SPRi has not often been applied to plasma samples, therefore further optimization may be needed to prevent non-specific binding of for example (lipo)proteins.
In conclusion, only the lactadherin+particle and EV concentration measured in plasma by
FCM differed significantly between patients and controls. Based on this result, FCM may be more promising for application to clinical samples compared to SPRi, taken into account the before mentioned challenges. In the future, larger cohort studies are needed to confirm the presence of small tdEVs in blood plasma and urine, and to see whether such EVs can be used to discriminate between prostate cancer patients and controls.
Supporting information
S1 File. Protocol spiking experiment.
(DOCX)
S1 Appendix.
Acknowledgments
We would like to acknowledge C.M. Hau for her assistance during the experiments.
Author Contributions
Conceptualization: Linda G. Rikkert, Leonie de Rond, Annemieke van Dam, Ton G. van
Leeuwen, Frank A. W. Coumans, Leon W. M. M. Terstappen, Rienk Nieuwland.
Data curation: Linda G. Rikkert, Leonie de Rond, Annemieke van Dam. Formal analysis: Linda G. Rikkert, Leonie de Rond, Annemieke van Dam. Investigation: Linda G. Rikkert, Leonie de Rond, Annemieke van Dam. Project administration: Linda G. Rikkert, Leonie de Rond.
Resources: Frank A. W. Coumans, Theo M. de Reijke, Rienk Nieuwland. Software: Leonie de Rond, Annemieke van Dam.
Supervision: Ton G. van Leeuwen, Frank A. W. Coumans, Leon W. M. M. Terstappen, Rienk
Nieuwland.
Validation: Linda G. Rikkert, Leonie de Rond, Annemieke van Dam. Visualization: Linda G. Rikkert, Leonie de Rond.
Writing – original draft: Linda G. Rikkert, Leonie de Rond.
Writing – review & editing: Linda G. Rikkert, Leonie de Rond, Annemieke van Dam, Ton G.
van Leeuwen, Frank A. W. Coumans, Theo M. de Reijke, Leon W. M. M. Terstappen, Rienk Nieuwland.
References
1. Nanou A, Coumans FAW, van Dalum G, Zeune LL, Dolling D, Onstenk W, et al. Circulating tumor cells, tumor-derived extracellular vesicles and plasma cytokeratins in castration-resistant prostate cancer patients. Oncotarget. 2018; 9(27):19283–93.https://doi.org/10.18632/oncotarget.25019PMID:
29721202
2. Lorente D, Olmos D, Mateo J, Bianchini D, Seed G, Fleisher M, et al. Decline in Circulating Tumor Cell Count and Treatment Outcome in Advanced Prostate Cancer. European urology. 2016; 70(6):985–92.
https://doi.org/10.1016/j.eururo.2016.05.023PMID:27289566
3. Lorente D, Ravi P, Mehra N, Pezaro C, Omlin A, Gilman A, et al. Interrogating Metastatic Prostate Can-cer Treatment Switch Decisions: A Multi-institutional Survey. European urology focus. 2018; 4(2):235– 44.https://doi.org/10.1016/j.euf.2016.09.005PMID:28753792
4. Coumans FAW, Doggen CJM, Attard G, de Bono JS, Terstappen LWMM. All circulating EpCAM+CK +CD45- objects predict overall survival in castration-resistant prostate cancer. Annals of Oncology. 2010; 21(9):1851–7.https://doi.org/10.1093/annonc/mdq030PMID:20147742
5. van der Pol E, Coumans FAW, Grootemaat AE, Gardiner C, Sargent IL, Harrison P, et al. Particle size distribution of exosomes and microvesicles determined by transmission electron microscopy, flow cytometry, nanoparticle tracking analysis, and resistive pulse sensing. J Thromb Haemost. 2014; 12 (7):1182–92.https://doi.org/10.1111/jth.12602PMID:24818656
6. Rikkert LG, van der Pol E, van Leeuwen TG, Nieuwland R, Coumans FAW. Centrifugation affects the purity of liquid biopsy-based tumor biomarkers. Cytometry Part A: the journal of the International Society for Analytical Cytology. 2018; 93(12):1207–12.
7. Lo¨tvall J, Hill AF, Hochberg F, Buza´s EI, Di Vizio D, Gardiner C, et al. Minimal experimental require-ments for definition of extracellular vesicles and their functions: a position statement from the Interna-tional Society for Extracellular Vesicles. Journal of extracellular vesicles. 2014; 3:https://doi.org/10. 3402/jev.v3.26913PMID:25536934
8. de Rond L, van der Pol E, Hau CM, Varga Z, Sturk A, van Leeuwen TG, et al. Comparison of Generic Fluorescent Markers for Detection of Extracellular Vesicles by Flow Cytometry. Clin Chem. 2018; 64 (4):680–9.https://doi.org/10.1373/clinchem.2017.278978PMID:29453194
9. Park YH, Shin HW, Jung AR, Kwon OS, Choi YJ, Park J, et al. Prostate-specific extracellular vesicles as a novel biomarker in human prostate cancer. Sci Rep. 2016; 6:30386.https://doi.org/10.1038/ srep30386PMID:27503267
10. Zaborowski MP, Lee K, Na YJ, Sammarco A, Zhang X, Iwanicki M, et al. Methods for Systematic Identi-fication of Membrane Proteins for Specific Capture of Cancer-Derived Extracellular Vesicles. Cell reports. 2019; 27(1):255–68.e6.https://doi.org/10.1016/j.celrep.2019.03.003PMID:30943406 11. Im H, Shao H, Park YI, Peterson VM, Castro CM, Weissleder R, et al. Label-free detection and
molecu-lar profiling of exosomes with a nano-plasmonic sensor. Nature biotechnology. 2014; 32(5):490–5.
https://doi.org/10.1038/nbt.2886PMID:24752081
12. Day KC, Lorenzatti Hiles G, Kozminsky M, Dawsey SJ, Paul A, Broses LJ, et al. HER2 and EGFR Over-expression Support Metastatic Progression of Prostate Cancer to Bone. Cancer Res. 2017; 77(1):74– 85.https://doi.org/10.1158/0008-5472.CAN-16-1656PMID:27793843
13. Date K, Ettelaie C, Maraveyas A. Tissue factor-bearing microparticles and inflammation: a potential mechanism for the development of venous thromboembolism in cancer. Journal of thrombosis and hae-mostasis: JTH. 2017; 15(12):2289–99.https://doi.org/10.1111/jth.13871PMID:29028284
14. van der Pol E, van Gemert MJ, Sturk A, Nieuwland R, van Leeuwen TG. Single vs. swarm detection of microparticles and exosomes by flow cytometry. Journal of thrombosis and haemostasis: JTH. 2012; 10 (5):919–30.https://doi.org/10.1111/j.1538-7836.2012.04683.xPMID:22394434
15. de Rond L, Libregts S, Rikkert LG, Hau CM, van der Pol E, Nieuwland R, et al. Refractive index to evalu-ate staining specificity of extracellular vesicles by flow cytometry. J Extracell Vesicles. 2019; 8
(1):1643671.https://doi.org/10.1080/20013078.2019.1643671PMID:31489142
16. Gool EL, Stojanovic I, Schasfoort RBM, Sturk A, van Leeuwen TG, Nieuwland R, et al. Surface Plasmon Resonance is an Analytically Sensitive Method for Antigen Profiling of Extracellular Vesicles. Clinical chemistry. 2017; 63(10):1633–41.https://doi.org/10.1373/clinchem.2016.271049PMID:28784692 17. Stravers CS, Gool EL, van Leeuwen TG, Aalders MCG, van Dam A. Multiplex body fluid identification
using surface plasmon resonance imaging with principal component analysis. Sensors and Actuators B: Chemical. 2019; 283:355–62.
18. van der Pol E, Sturk A, van Leeuwen T, Nieuwland R, Coumans F, group ISVW, et al. Standardization of extracellular vesicle measurements by flow cytometry through vesicle diameter approximation. J Thromb Haemost. 2018; 16(6):1236–45.https://doi.org/10.1111/jth.14009PMID:29575716
19. Eitan E, Green J, Bodogai M, Mode NA, Baek R, Jorgensen MM, et al. Age-Related Changes in Plasma Extracellular Vesicle Characteristics and Internalization by Leukocytes. Sci Rep. 2017; 7(1):1342.
https://doi.org/10.1038/s41598-017-01386-zPMID:28465537
20. Lok CA, Jebbink J, Nieuwland R, Faas MM, Boer K, Sturk A, et al. Leukocyte activation and circulating leukocyte-derived microparticles in preeclampsia. American journal of reproductive immunology (New York, NY: 1989). 2009; 61(5):346–59.
21. Rupp AK, Rupp C, Keller S, Brase JC, Ehehalt R, Fogel M, et al. Loss of EpCAM expression in breast cancer derived serum exosomes: role of proteolytic cleavage. Gynecologic oncology. 2011; 122 (2):437–46.https://doi.org/10.1016/j.ygyno.2011.04.035PMID:21601258
22. Coumans F, van Dalum G, Terstappen L. CTC Technologies and Tools. Cytometry Part A: the journal of the International Society for Analytical Cytology. 2018; 93(12):1197–201.
23. Nanou A, Zeune LL, Terstappen L. Leukocyte-Derived Extracellular Vesicles in Blood with and without EpCAM Enrichment. Cells. 2019; 8(8).
24. Rao CG, Chianese D, Doyle GV, Miller MC, Russell T, Sanders RA Jr., et al. Expression of epithelial cell adhesion molecule in carcinoma cells present in blood and primary and metastatic tumors. Interna-tional journal of oncology. 2005; 27(1):49–57. PMID:15942643
25. Biggs CN, Siddiqui KM, Al-Zahrani AA, Pardhan S, Brett SI, Guo QQ, et al. Prostate extracellular vesi-cles in patient plasma as a liquid biopsy platform for prostate cancer using nanoscale flow cytometry. Oncotarget. 2016; 7(8):8839–49.https://doi.org/10.18632/oncotarget.6983PMID:26814433
26. Padda RS, Deng FK, Brett SI, Biggs CN, Durfee PN, Brinker CJ, et al. Nanoscale flow cytometry to dis-tinguish subpopulations of prostate extracellular vesicles in patient plasma. The Prostate. 2019; 79 (6):592–603.https://doi.org/10.1002/pros.23764PMID:30680751
27. Logozzi M, Angelini DF, Iessi E, Mizzoni D, Di Raimo R, Federici C, et al. Increased PSA expression on prostate cancer exosomes in in vitro condition and in cancer patients. Cancer letters. 2017; 403:318– 29.https://doi.org/10.1016/j.canlet.2017.06.036PMID:28694142