Edition 2022 Feb. 28

Speed Controllers

4-Quadrant PWM configurable via PC

SC 5008 S

Values at 22°C SC 5008 S

Power supply electronic UP 6 ... 50 V DC

Power supply motor Umot 0 ... 50 V DC

PWM switching frequency 1) fPWM 96 kHz

Efficiency electronic

η

95 %

Max. continuous output current Icont 8 A

Max. peak output current 2) Imax 16 A

Standby current for electronic (@ UP =24V) lel 0,1 A

Operating temperature range -25 ... +60 °C

Housing material zinc, black coated

Mass 160 g

Interfaces

Configuration of setpoint specifications, operating mode and controller parameters via USB programming adapter for Speed Controller.

Basic features

Speed-controlled operation of:

■DC-Micromotors operated with incremental encoders

■Brushless DC-Servomotors operated with digital or analog Hall sensors

■Brushless DC-Servomotors operated with digital Hall sensors and incremental encoders

■Brushless DC-Servomotors operated with absolute encoders Note: For version, see options and connection information.

Range of functions

Description Intermittent operation with up to double the continuous current.

Separate voltage supply for motor and electronics.

Integrated speed control by means of PI controller.

Setpoint input of the speed via PWM or analog voltage value.

Switching input for defining the direction of rotation of the motor.

Digital output, can be programmed either as frequency output or as error output Additional functions Integrated current limitation to protect against thermal overload.

Can optionally be operated in voltage controller mode or fixed speed mode.

1) for brushless DC-Motors without Hall sensors: fPWM = 24 kHz

2) S2 mode for max. 6s

For notes on technical data and lifetime performance

refer to “Technical Information”. © DR. FRITZ FAULHABER GMBH & CO. KG

Specifications subject to change without notice.

www.faulhaber.com

(2)

Edition 2022 Feb. 28 Dimensional drawing

SC 5008 S

(5x)ø3,5

65 5018 3,6

(4x)

22±0,3

3±0,2

RM 5 40 50 58

1

8 9

16

Scale reduced

Options and connection information

4763 4289 3980 4764 3530 3531 4475 44766339 6340

Option Description

Example product designation: SC 5008 S 3530 Type

Absolute encoder 2 pole motors Analog Hall sensors 2 pole motors Absolute encoder 4 pole motors Analog Hall sensors 4 pole motors Digital Hall sensors 2 pole motors

Digital Hall sensors 4 pole motors Digital Hall sensors 14 pole motors Incremental encoder

Digital Hall sensors + incremental encoder Digital Hall sensors + brake/enable

Function

No. No. Function

Connection

Note: For details on the connection assignment, see device manual SC.

9 Mot C 10 Mot B 11 Mot A 12 SGND 13 VCC

14 Sens C 15 Sens B 16 Sens A 1 UP

2 Umot

3 GND 4 Unsoll

5 DIR 6 FG 7 IO 2 8 IO 1 BL

BL BL BL BL DC BL BL BL BL

Product combination

DC-Motors Brushless DC-Motors

2237 ... CXR 2342 ... CR 2642 ... CR 2642 ... CXR 2657 ... CR 2657 ... CXR 2668 ... CR 3242 ... CR 3257 ... CR 3272 ... CR 3863 ... CR 3890 ... CR

1645 ... BHS 1660 ... BHS 1660 ... BHT 2057 ... B 2057 ... BA 2232 ... BX4 2250 ... BX4 2264 ... BP4 2444 ... B 3056 ... B 3242 ... BX4 3268 ... BX4 3274 ... BP4 3564 ... B 4221 ... BXT R 4221 ... BXT H 4490 ... B 4490 ... BS

Cables / Accessories

To view our large range of ac- cessory parts, please refer to the

„Accessories“ chapter.

For notes on technical data and lifetime performance

refer to “Technical Information”. © DR. FRITZ FAULHABER GMBH & CO. KG

Specifications subject to change without notice.

www.faulhaber.com

Referenties

GERELATEERDE DOCUMENTEN

In Nederland worden deze virussen gebruikt in kassen voor de bestrijding van de rupsen van de flo- ridamot, Spodoptera exigua (Spod-X) in onder meer in chrysant, gerbera en

De aan- dacht voor de ontwikkeling waarin het wiskunde- onderwijs zich momenteel bevindt is niet afwezig, gezien bijvoorbeeld de verwijzing die af en toe plaats vindt naar

Voor goed lopende materialen blijkt dat in tegenstelling tot vloei- stoffen, per tijdseenheid dezelfde hoeveelheid materiaal uit de bun- ker loopt onafhankelijk van

Vooral zwemmen is minder effectief, omdat het lichaam dan niet echt wordt belast; het wordt gedragen door water. Wel maakt zwemmen de spieren en gewrichten los, zeker zwemmen in

Based on the voltage unbalance factor and the system’s capacity, the inverter absorbs a small amount of negative-sequence current from the grid, thereby correcting the

Operation with only one of the (in this case) two TPM circuits, is equal to a standard three phase inverter, and the SFBM configuration with only one working module in the faulty

Each supply current membership function has 50% overlaps with its neighbor membership function (functions). We have considered five Gaussian membership functions for derivative

In het rapport wordt geconcludeerd dat naast (snoei)hout, gras de meest perspectiefvolle stroom biomassa is voor energieopwekking. Voor de verwerking van gras wordt gekozen voor