• No results found

University of Groningen Iron nanoparticles by inert gas condensation Xing, Lijuan

N/A
N/A
Protected

Academic year: 2021

Share "University of Groningen Iron nanoparticles by inert gas condensation Xing, Lijuan"

Copied!
19
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

Iron nanoparticles by inert gas condensation

Xing, Lijuan

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date: 2018

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

Xing, L. (2018). Iron nanoparticles by inert gas condensation: Structure and magnetic characterization. University of Groningen.

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

Chapter 5 

 

Magnetic  Force  Microscopy  Determination  of  Iron 

Nanoparticles Magnetization 

M

agnetic Force Microscopy can probe the magnetic properties of 

individual  nanoparticles,  and  provide  precise  and  localized 

information of their magnetic structure. Iron NPs with sizes ~50‐70 

nm  were  imaged  by  MFM  using  magnetic  CoCr  coated  Si  probes 

with a proper tip‐sample separation to minimize direct topography 

effects. The bright and dark contrast observed in the phase images 

agreed  with  the  single‐domain  magnetic  structure.  Indeed,  the 

MFM  phase  images  recorded  with  opposite  tip  polarity  showed 

inversed contrasts, confirming the ferromagnetism of the measured 

Fe NPs. Furthermore, the orientation of the NP magnetization was 

simulated by modeling the NP and the magnetic CoCr coating as 

point  dipoles.  It  turned  out  that  as‐deposited  Fe  NPs  showed 

random  assemblies  with  no  preferential  orientation  due  to  large 

interparticle  distances.  The  sharp  topographical  feature  of  NPs 

contributed to the additional side contrasts observed in the MFM 

phase  images.  At  any  rate,  the  detailed  determination  of  the 

remnant  magnetization  orientation  of  the  Fe  nanostructures,  and 

their domain structure configuration, is beneficial in a multitude of 

applications where the magnetization of isolated magnetic NPs on 

surfaces is required. 

(3)

5.1 Introduction

Magnetic nanoparticles (NPs) have been extensively studied due to their applications in a variety of fields such as data storage1,2 and biomedicine3–7

including contrast enhancement in magnetic resonance imaging (MRI), drug delivery, and hyperthermia. The preparation of magnetic NPs can be achieved by various methods, among which inert gas condensation (IGC) provides the technical ability to produce high purity magnetic NPs with nanometric scale precision and diverse motifs. This bottom-up method of material growth and assembly make it possible to control the morphology and size to allow for tailored magnetic properties8,9.

In ultrafine magnetic nanostructures, such as Fe NPs in this work, the magnetic properties are dramatically different from the bulk matter. Moreover, the magnitude of ferromagnetic NP moment, particularly of the 3d series, can be influenced by the band structure10. In the near surface region the magnetic moment per atom

experiences drastic variation with the distance from the surface due to the discreteness, which results from reduced coordination at the surface, leading to an improved moment of NPs such as Fe, Co and Ni compared to their bulk counterparts11,12. As the size of the NP is downscaled to a level that is comparable

to key magnetic length scale, such as the exchange length (in nm ranges) or the domain wall size (in nm-µm ranges), the magnetization configuration may also be distinctly affected13,14. Standard magnetic characterization techniques, as for

example the superconducting quantum interference devices (SQUIDs), were used to investigate the magnetic properties of NPs as ensembles of the nanostructures or the macro-performance15. Nevertheless, for many applications it is beneficial to

probe the isolated magnetic NPs, since under this condition the remnant magnetization of the nanostructure and domain structure configuration can be detected in detail16. Imaging and spatially localizing such nanometric scale

magnetic structure is of strong interest as a better understanding of the individual NP magnetization configuration, which is advantageous not only for the fundamental physics of nanomagnetism but also for specific technology applications1–7.

Magnetic Force Microscopy (MFM) offers significant access to characterize magnetic properties of individual NPs17–20 instead of the integral properties of

ensembles of NPs, which cannot be achieved by standard characterization techniques21. In MFM measurements, a cantilever with a micro-fabricated magnetic

tip at the end scans across the sample surface with a given tip-sample separation. The tip magnetization (normally in the z-direction, perpendicular to the sample

(4)

surface), together with the magnetic field originating from the sample, results in an either attractive or repulsive interaction. The force gradient acting upon the tip is embodied in the variation of the cantilever oscillation behavior (i.e. amplitude and/or phase shift)22, and it can be detected for imaging the magnetic configuration

of the sample. This high resolution imaging of nanomagnetism gives a precise local characterization of the magnetic domain structure23 to study the finite-size effects

of the NPs and the enhanced properties with respect to their bulk counterparts. In this chapter, high resolution magnetic imaging of the Fe NPs has been carried out by MFM. And analysis of the magnetic properties has shown that the NPs with sizes ~50-70 nm are single-domain ferromagnetic crystals. Moreover, the magnetic contrast from MFM images was fitted using magnetic dipole models (Equation (2) and (3)) to obtain the magnetization orientation of the measured NPs.

5.2 Experimental Section

Fe NPs were deposited directly onto silicon wafers and carbon-coated transmission electron microscopy (TEM) grids by inert gas condensation using a home modified high pressure magnetron sputtering source24,25. The subsequent exposure to the

ambient atmosphere resulted in the initial surface oxidation of the NPs8,9. High

resolution TEM imaging (see Figure 5.1) have shown the NPs were consisted of an Fe core surrounded by an iron oxide shell (with thickness ~3nm independent of the particle size)8, yielding an overall average NP size of ~33.4 nm with a standard

deviation of 11.0 nm.

For the MFM study, samples were imaged in air using a Multimode Atomic Force Microscope (AFM) with CoCr coated Si probes (MESP-V2 tips with the CoCr coating thickness of 50 nm). The data were recorded with a scan rate of 0.3 Hz and with 512 lines/pixels per scan direction. The magnetization of the probe was attained by placing a permanent NdFeB block magnet (nickle-plated, size: 40×20×5 mm) directly underneath the AFM tip holder. The d adjacent magnetic poles resulted in a magnetic stray field directing into or out of the sample surface. Furthermore, the MFM approach is essentially a two-pass technique. First the scanning of the sample takes place, where short range interactions (e.g. Van der Waals forces) play dominant role, and topographical information is collected. Subsequently, the phase shift Δφ of the cantilever oscillation is recorded in lift mode with the cantilever raised up to ~50-60 nm above the sample surface, following the topography pattern from the previous scanning, in order to reflect the true magnetic signal due to the stray fields of the sample. The chosen lift height should ensure sufficient separation where the topographic artifacts are eliminated

(5)

and magnetic interactions prevail. All topography AFM and MFM images were flattened to eliminate any virtual sample tilt26, and no further processing took place.

The phase shift variation Δφ along the trace in lift mode is proportional to the magnetic force gradient in z direction. According to Henry’s work on nanowires13

and Ramlan’s work on quantum dots27, the z derivative of the magnetic force

contrast Δφ given by Eqation (4) can be described as a function of the tip position expressed by the y and z coordinates. The magnetization orientation of the NP is described by the angle θ between the MFM tip magnetic moment and the NP magnetization. Finally, by changing the parameters in the force function, the phase shift at each tip position can be numerically modeled. The simulated phase shift profile can be fitted to the experimental data. The fitting process employed here is the downhill Simplex method due to Nelder and Mead28,29. In the phase shift curve

Δφ= Δφ(y) the horizontal axis corresponds to the tip position on the y axis. The χ2 in the fitting procedure was defined as the variance between the experimental data Δφi and the modeled data Δφi, cal as χ2=Σ ∆ ∆ , . For the Simplex method

reasonable starting estimates for all the fitting parameters have to be provided, and varying the input parameters in Equation (5.4) the fitting was optimized by minimizing χ2.

5.3 Results and Discussion

A TEM overview image of the Fe NPs deposited on a carbon-coated TEM grid is shown in Figure 5.1(a). A characteristic selected area electron diffraction (SAED) pattern from an area of the sample containing several NPs is shown in Figure 5.1(b) and indicates the presence of bcc Fe and Fe oxide (Fe3O4 and/or γ-Fe2O3)8. Indeed,

in a previous work8 it has been demonstrated that the Fe NP constitutes of a bcc-Fe

core surrounded by an iron oxide shell. Figure 5.1(c) presents the height topography image collected in tapping mode. The height and size of the NPs was determined by fitting a two-dimensional parabolic function to the height profile extracted from each particle through the center, which is an approximation in good agreement with the TEM analysis21. The contrast observed in the corresponding MFM phase image

(Figure 5.1(d)) has indicated that the phase shift of the cantilever oscillation was caused mainly by the magnetic tip-sample interaction. A dark contrast (negative phase shift relative to the background signal) indicates an attractive interaction, while a bright contrast (positive phase shift) indicates a repulsive interaction30. The

bright and dark contrast was in agreement with single-domain magnetic NPs, while some of the particles showed a dipole contrast resulting from the interaction of the

(6)

in-plane particle magnetization and the external out-of-plane magnetization of the probe.

Figure 5.1 (a) Overview image of the Fe NPs deposited on a carbon‐coated TEM grid; (b) 

selected  area  diffraction  pattern  of  the  deposited  NPs  that  agrees  with  a  structure  composed of a bcc Fe core and a magnetite/maghemite shell (the labels indicate the dhkl  interplanar distances in  ); (c) the height topography image collected in tapping mode; (d)  the corresponding MFM phase image was recorded in lift mode with  60 nm lift height (tip‐ sample separation) where the magnetic forces give the most significant contribution on  the phase shift variation Δφ of the oscillating cantilever. The AFM/MFM scanning area is  5×5 µm2.  

(7)

Prior to scanning Fe NPs, MFM measurements were performed on a standard magnetic sample in order to confirm that the tip was properly magnetized (see Figure 5.5 in Appendix). Moreover, the scan angle was varied to check if the asymmetry of the NP morphology influenced the outcome since the tip radius is non-negligible during scanning nanometer scale structures (see Figure 5.6 in Appendix). To explore the magnetic property of Fe NPs, the MFM tip was magnetized in two opposite directions: pointing into (Figure 5.2(a)), and out of (Figure 5.2(b)) the silicon surface plane. The MFM phase images shown in Figure 5.2(c) and (d) were taken on the same NP with the tip magnetized into and out of the silicon surface plane, representing the magnetic moment projection in x-y plane. The phase shift profiles demonstrated in Figure 5.2(e) were extracted from the phase images along the dash line, whose position and direction were indicated in Figure 5.2(c) and (d), with the substrate background subtracted.

The Fe NPs, besides the ferromagnetism of the bulk counterpart, exhibit distinct magnetic configurations depending on the particle size. The critical size for multi- and single-domain ferromagnetic NPs is given approximately by 2 ⁄ , where A is the exchange constant and M

S is the saturation magnetization31. Below this critical size, the ferromagnetic NP behaves as a

single-domain structure. When the NP is downscaled further approaching the superparamagnetic limit, the total magnetization behaves as a super-spin inside each particle showing no coercivity32,33. As it can be identified from the MFM phase

images, the into-plane magnetized tip produced a dark-bright-dark contrast, which indicated an attractive-repulsive-attractive magnetic force configuration, while an inversed contrast was observed when the tip was magnetized out of the substrate surface. This shows a clear indication of the ferromagnetism of the Fe NP, with the corresponding phase shift profiles in Figure 5.2(e) demonstrating a consistent result. The possibility of being paramagnetic can be excluded as the local magnetic moment, in the case of paramagnetism, would align with the magnetic field of the tip without variation using reversed tip magnetizations27.

5.4 Comparison with Theory

The long range magnetic interactions between the tip and the NP result in the variation of the mechanical behavior of the cantilever34. In our experiments, the

phase shift Δφ originated from the magnetic field of the NP was used to characterize the magnitude of the magnetic force, which is proportional to the z derivative of the magnetic force and it is given by35

(8)

Figure  5.2  Schematic  of  the  MFM  measurement  geometry  is  shown  with  the  tip  magnetized in two opposite directions: pointing into (a) and out of (b) the sample surface  plane. MFM phase images recorded with the tip magnetization pointing into and out of  the sample surface show inversed contrasts, indicating the ferromagnetism of the NPs. The  phase profile (c) was extracted along the dash line (from left to right) with the asterisk as  the origin of the x axis (x=0). The variation of the phase shift Δφ caused by the magnetic  field of the NP is shown in (e), which quantitatively shows the inversion of the contrast  relative to the substrate. The MFM scanning took place at a lift height of 60 nm. The MFM  phase  images  are  350×180  nm2  in  size,  and  the  size  of  the  NP  is  approximately  56  nm  according  to  the  topographic  information  obtained  in  tapping  mode  (see  Figure  5.7  in  Appendix).  

(9)

mag F k Q '   (5.1)

Where Q is the quality factor of the cantilever, and k is the spring constant of the cantilever. Various levels of approximations could be applied to theoretically evaluate the magnetic force gradient exerted on the MFM tip, depending on the degree of the complexity of the model employed to describe the magnetization state of both the tip and the NP13. In our approach, the magnetized tip and the NP were

modeled as magnetic point dipoles13,27,36 as it is shown in Figure 5.3(a). Although

we adopted an earlier model 13,27, it was modified for the measurement of isolated

magnetic NPs. The position vector of the magnetic tip with respect to the center of the NP (at

r

0

) is denoted by

r

x

x

y

y

z

z

 , and the point magnetic moment at the tip position is given by

=mNP

x

y

z

where mNP is the

magnitude of the NP magnetic dipole moment, as well as α, β, and γ are the direction cosines of the magnetic moment. The stray field emanating from the magnetic NP is given by13,27 3 5

)

(

3

r

r

r

r

H

NP

(5.2)

The magnetic force gradient (i.e. the z derivative of the force), which is detected by the probing tip of the MFM, reflects the interaction between the NP and the magnetized tip and it is given by13,27

2 2( ˆ) ' z z H m F NP tip mag     (5.3)

The orientation of the magnetization of the NP is characterized by the angle

between the magnetic moment of the NP and the equivalent magnetic moment of the tip. Figure 5.3(a) shows that  sin  and  cos. Upon substitution the phase shift Δφ is given by 13,27

                 9/2 2 2 3 2 / 7 2 2 2 / 5 2 2 cos sin 105 cos 2 sin 45 cos 9 ' z y z y z z y z y z z y C F mag       (5.4)

(10)

where C = mtip mNP . The magnetic force gradient F'mag in Equation (5.3) was defined as a function of the tip position (described by y and z, extracted and modified from the height information (y0, z0) collected in tapping mode) and the orientation of the NP magnetization (as described by the angle θ).

As the center of the dipole-modeled tip should be located at a raised height

h

'

with respect to the surface point of the tip-apex, this additional parameter should be taken into account, besides the lift height h, when describing the tip trajectory (y = y0, z = z0+h+h'). Equation (5.4) was used to fit the phase shift data in lift mode along the dash line shown in Figure 5.2(c) and (d). The experimental phase shift profile and the fitting are shown in Figure 5.3(b) and (c). A multitude of different values for θ were used to optimize the fitting. The results show that the NP dipole is along the dash line and at an angle of 177 ̊ and –6 ̊ , respectively, with respect to the tip magnetic moment, as shown at the right of Figure 5.3(b) and (c). With the polarity of the MFM probe reversed, the corresponding phase imaging exhibited a consistent orientation of the ferromagnetic NP.

Finally, based on the measurements of a large number of NPs, as-deposited Fe NPs on silicon substrate showed no preferential orientation due to large interparticle distances. Phase images with different magnetization orientation were shown in Figure 5.4, showing the evolution of the phase images with θ varying from 0 ̊ to 315 ̊. Fe NPs with a magnetization oriented parallel or antiparallel (θ = 0 ̊ or 180 ̊ ) to the magnetic moment of the tip showed a nearly whole bright (dark) contrast with both sides slightly dark (bright), instead of an entire bright (dark) contrast indicating absolute repulsion (attraction). Li et al.15 modulated the phase

of the measured in-phase signals by adding an extra phase using the signal processing algorithm. The adjusted phase images for an equivalent vertical (upward and downward) magnetization demonstrated consistent contrasts. The additional side contrasts may be attributed to the strong non-rectilinear trajectory of the magnetic probe, which is the convolution of the NP section shape with the tip-apex shape13. Although it is less pronounced as the NP orientation tends towards the

in-plane direction, this effect may indeed occur at whatever orientation angle θ. When the magnetization is oriented in-plane (perpendicular to the tip moment, θ = 90 ̊ or 270 ̊ ), the phase image shows a half-dark (bright) and half-bright (dark) contrast without side contrasts. Fe NPs with opposite magnetization were shown inversed phase contrasts.

(11)

Figure 5.3 Determination for isolated NP of the magnetization orientation. The schematic 

of the MFM measurement in (a) shows the trace of the magnetic tip in lift mode, along  which  the  phase  shift  Δφ  of  the  cantilever  resulting  from  the  magnetic  force  gradient  produced by the NP. The experimental data in (b) and (c) is obtained from Figure 2(c) and  (d) along the dash line. The fitting (red diamond) of the one‐dimensional MFM phase shift 

(12)

profile (black circle) verifies that the NP is described well as a single‐domain structure. The  value of θ giving the minimum χ2 yields the magnetization orientation. Fitting of the phase  shift collected on the same NP with opposite tip magnetization (pointing out of (b) and into  (c) the substrate surface) gives comparable results as it is shown in the right column of (b)  and (c). The small arrow within the circle under the tip represents the alignment of the  individual magnetic dipole moment that may act as the field source.     

Figure  5.4 (a)  Evolution  of  the  estimated  MFM  phase  images  with  NP  magnetization 

orientation that is defined by the angle θ. (b) This schematic shows how θ is defined. All  the phase images were collected with a 60 nm lift height. The magnetic moment is along  the y axis in the x‐y plane. 

5.5 Conclusions

Fe NPs size ~50-70 nm were produced on silicon substrate by inert gas condensation. MFM measurement based on AFM technique revealed the single-domain ferromagnetism of the deposited Fe NPs, giving a precise and localized characterization of the nano scale magnetic structure. The phase images collected on the same NP with opposite tip magnetization (pointing into and out of the sample surface plane) in lift mode with a 60 nm tip sample separation showed inversed contrast, which indicated the reversion of the magnetic force gradient in z direction and proved the permanent magnetization of the NP. The magnetic moment projection in x-y plane can be derived by symmetry. Subsequently the magnetization orientation is determined by the spatial angle between the tip and the magnetic moment of the NP, which derived by direct fitting of the MFM phase

(13)

data using a dipole-dipole interaction model, providing possibilities to study precisely the NP anisotropy. The non-rectilinear trajectory of the scanning tip, resulted possibly from the sharp topographical feature of the NPs combined with the tip-apex shape, contributed to additional side contrasts observed in the phase images. Random magnetic orientations were observed, and our measurements have shown a magnetization orientation variation in the range ~0-315 ̊ with respect to the out of plane direction.

(14)

Appendix

        Figure 5.5 The MFM measurements were performed on a standard mangetic sample to  confirm the proper functioning of the magnetic probe with tip mafnetized into (a‐c) and  out of (c‐f) the sample surface. The phase profile shown in (c) and (f) were extracted along  the  solid  line  marked  in  (b)  and  (e),  respectively.  The  correspongding  solid  line  in  the  topography images (a, d)  proved that the extracted profiles reflected exactly the same  area.  The  contrary  contrasts  in  the  phase  images  and  the  reversal  of  the  profiles  manifested that the tip was magnetized properly. The scanning area was 3.5×5 µm2.  

(15)

 

Figure 5.6 Scan angle was varied to check if the asymmetry of the NP morphology affected 

the outcome. MFM phase profiles of the same NP while scanning with different angles are  shown  with the  according phase  images  listed  in  the  right  indicating  the  consistency  of  scanning along different directions.  -200 -100 0 100 200 0 20 40 60 exp Parabola fit Height (nm) Y (nm)   Figure 5.7 The topography line scan across the NP was used to determine the particle size  by fitting a two‐dimensional parabolic function to the peak area. The vertex of the parabola  (56.4) was approximated as the NP size. 

(16)

References

1. Reiss, G. & Hütten, A. Magnetic nanoparticles: Applications beyond data storage. Nat. Mater. 4, 725-726 (2005).

2. S, S. & D, W. Self assembling magnetic nanomaterials. J. Magn. Soc. Jpn. 25, 1434-1440 (2001).

3. Lu, A.-H., Salabas, E. L. & Schüth, F. Magnetic nanoparticles: synthesis, protection, functionalization, and application. Angew. Chem. Int. Ed. 46, 1222-1244 (2007).

4. Ito, A., Shinkai, M., Honda, H. & Kobayashi, T. Medical application of functionalized magnetic nanoparticles. J. Biosci. Bioeng. 100, 1-11 (2005). 5. Gao, J., Gu, H. & Xu, B. Multifunctional magnetic nanoparticles: design,

synthesis, and biomedical applications. Acc. Chem. Res. 42, 1097-1107 (2009). 6. Hao, R. et al. Synthesis, functionalization, and biomedical applications of

multifunctional magnetic nanoparticles. Adv. Mater. 22, 2729-2742 (2010). 7. Soni, G. & Yadav, K. S. Applications of nanoparticles in treatment and

diagnosis of leukemia. Mater. Sci. Eng. C 47, 156-164 (2015).

8. Xing, L. et al. Synthesis and morphology of iron-iron oxide core-shell nanoparticles produced by high pressure gas condensation. Nanotechnology 27, 215703 (2016).

9. Xing, L., ten Brink, G. H., Kooi, B. J. & Palasantzas, G. Preparation of tunable-sized iron nanoparticles based on magnetic manipulation in inert gas condensation (IGC). J. Appl. Phys. 121, 024305 (2017).

10. Kodama, R. H. Magnetic nanoparticles. J. Magn. Magn. Mater. 200, 359-372 (1999).

11. Billas, I. M. L., Chatelain, A. & de Heer, W. A. Magnetism from the Atom to the Bulk in Iron, Cobalt, and Nickel Clusters. Science 265, 1682-1684 (1994). 12. Billas, I. M. L., Châtelain, A. & de Heer, W. A. Magnetism of Fe, Co and Ni

clusters in molecular beams. J. Magn. Magn. Mater. 168, 64-84 (1997). 13. Henry, Y. et al. Magnetic anisotropy and domain patterns in electrodeposited

cobalt nanowires. Eur. Phys. J. B - Condens. Matter Complex Syst. 20, 35-54 (2001).

14. Fraile Rodríguez, A. et al. Size-dependent spin structures in iron nanoparticles. Phys. Rev. Lett. 104, (2010).

15. Li. X., Li, Z., Pan, D., Yoshimura, S. & Saito, H. Dynamic nanomagnetism characterization of individual magnetic nanoparticles by frequency-modulated magnetic force microscopy. Appl. Phys. Lett. 104, 213106 (2014).

16. Albrecht, M. et al. Scanning force microspy study of biogenic nanoparticles for medical applications. J. Magn. Magn. Mater. Part 1, 269-271 (2005).

(17)

17. Moya, C. et al. Direct imaging of the magnetic polarity and reversal mechanism in individual Fe3-xO4 nanoparticles. Nanoscale 7, 8110-8114 (2015).

18. Schreiber, S. et al. Magnetic force microscopy of superparamagnetic nanoparticles. Small 4, 270-278 (2008).

19. Nocera, T. M., Chen, J., Murray, C. B. & Agarwal, G. Magnetic anisotropy considerations in magnetic force microscopy studies of single superparamagnetic nanoparticles. Nanotechnology 23, 495704 (2012).

20. Häberle, T. et al. Towards quantitative magnetic force microscopy: theory and experiment. New J. Phys. 14, 043044 (2012).

21. Sievers, S. et al. Quantitative measurement of the magnetic moment of individual magnetic nanoparticles by magnetic force microscopy. Small 8, 2675-2679 (2012).

22. Kebe, T. & Carl, A. Calibration of magnetic force microscopy tips by using nanoscale current-carrying parallel wires. J. Appl. Phys. 95, 775-792 (2004). 23. Diebel, C. E., Proksch, R., Green, C. R., Neilson, P. & Walker, M. M. Magnetite

defines a vertebrate magnetoreceptor. Nature 406, 299-302 (2000).

24. Krishnan, G. et al. Synthesis and exceptional thermal stability of Mg-based bimetallic nanoparticles during hydrogenation. Nanoscale 6, 11963-11970 (2014).

25. Chen, B., Brink, G. H. ten, Palasantzas, G. & Kooi, B. J. Size-dependent and tunable crystallization of GeSbTe phase-change nanoparticles. Sci. Rep. 6, srep39546 (2016).

26. Nečas, D. & Klapetek, P. Gwyddion: an open-source software for SPM data analysis. Open Phys. 10, 181-188 (2011).

27. Ramlan, D. G. et al. Ferromagnetic self-assembled quantum dots on semiconductor nanowires. Nano Lett. 6, 50-54 (2006).

28. Nelder, J. A. & Mead, R. A simplex method for function minimization. Comput. J. 7, 308-313 (1965).

29. Chen, B., Momand, J., Vermeulen, P. A. & Kooi, B. J. Crystallization kinetics of supercooled liquid Ge-Sb based on ultrafast calorimetry. Cryst. Growth Des.

16, 242-248 (2016).

30. Červenka, J., Katsnelson, M. I. & Flipse, C. F. J. Room-temperature ferromagnetism in graphite driven by two-dimensional networks of point defects. Nat. Phys. 5, 840-844 (2009).

31. Frei, E. H., Shtrikman, S. & Treves, D. Critical size and nucleation field of ideal ferromagnetic particles. Phys. Rev. 106, 446-455 (1957).

(18)

32. Wu, L., Mendoza-Garcia, A., Li, Q. & Sun, S. Organic phase syntheses of magnetic nanoparticles and their applications. Chem. Rev. 116, 10473-10512 (2016).

33. Batlle, X. & Labarta, A. Finite-size effects in fine particles: magnetic and transport properties. J. Phys. Appl. Phys. 35, R15-R42 (2002).

34. Proksch, R. B. et al. Magnetic force microscopy of the submicron magnetic assembly in a magnetotactic bacterium. Appl. Phys. Lett. 66, 2582-2584 (1995). 35. Li, L. H. & Chen, Y. Electric contributions to magnetic force microscopy

response from graphene and MoS2 nanosheets. J. Appl. Phys. 116, 213904 (2014).

36. Hartmann, U. The point dipole approximation in magnetic force microscopy. Phys. Lett. A 137, 475-478 (1989).

(19)

Referenties

GERELATEERDE DOCUMENTEN

The modified magnetic field configuration not only broadens the attainable range of particle sizes for a selected target material but also promotes the particle shape and

Therefore, magnetic force microscopy was employed to study the magnetic property and structure of individual iron nanoparticles with sizes ~50-70 nm. The reversal of

Samenvatting   M agnetische nanodeeltjes zijn van groot belang voor onderzoekers uit een breed scala van disciplines, zoals katalyse, magnetische gegevensopslag,

Xukai, Weiteng, Xiaotian and Heng, it’s my great pleasure to meet you guys in our group, and I really appreciate all the good times we have together in Groningen, dinners,

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright

In magnetic resonance imaging (MRI), superparamagnetic iron oxide particles are now commercially used as contrast enhancers, and the applied high magnetic field results in

A separation between the iron target and the magnetron is adopted to modify the effective magnetic field configuration upon the target for easy sputtering. Nevertheless, too