• No results found

Evaluating the performance of thermal sensation prediction with a biophysical model

N/A
N/A
Protected

Academic year: 2021

Share "Evaluating the performance of thermal sensation prediction with a biophysical model"

Copied!
11
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

Evaluating the performance of thermal sensation prediction

with a biophysical model

Citation for published version (APA):

Schweiker, M., Kingma, B. R. M., & Wagner, A. (2017). Evaluating the performance of thermal sensation

prediction with a biophysical model. Indoor Air, 27(5), 1012-1021. https://doi.org/10.1111/ina.12372

DOI:

10.1111/ina.12372

Document status and date:

Published: 01/09/2017

Document Version:

Publisher’s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Please check the document version of this publication:

• A submitted manuscript is the version of the article upon submission and before peer-review. There can be

important differences between the submitted version and the official published version of record. People

interested in the research are advised to contact the author for the final version of the publication, or visit the

DOI to the publisher's website.

• The final author version and the galley proof are versions of the publication after peer review.

• The final published version features the final layout of the paper including the volume, issue and page

numbers.

Link to publication

General rights

Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. • Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain

• You may freely distribute the URL identifying the publication in the public portal.

If the publication is distributed under the terms of Article 25fa of the Dutch Copyright Act, indicated by the “Taverne” license above, please follow below link for the End User Agreement:

www.tue.nl/taverne Take down policy

If you believe that this document breaches copyright please contact us at: openaccess@tue.nl

providing details and we will investigate your claim.

(2)

1012  

|

  wileyonlinelibrary.com/journal/ina © 2017 John Wiley & Sons A/S. Indoor Air. 2017;27:1012–1021.

Published by John Wiley & Sons Ltd

1 | INTRODUCTION

For near- steady- state thermal environments, it is widely established that humans express on average a neutral thermal sensation when they are in thermal conditions allowing their body to maintain heat balance without sweating. Elaborate experiments and analyses have provided a wealth of information on this topic and have led to heat balance equations that are used in international thermal comfort standards.1,2

When applying these heat balance equations, the average human is often represented as a single node with a specific metabolic rate (=heat production) associated with an activity level. For typical office

conditions, the activity level is assumed between 1.0 and 1.2 METs (heat equivalent by convention 58- 70 W/m2).1,3 For near- steady- state

thermal indoor environments, which allow the body to maintain heat balance, it is then assumed that the body is able to maintain the inter-nal temperature, ie, the body core temperature, within physiologically healthy boundaries. Thereby, the internal heat balance is a function of metabolic rate and body tissue insulation and is constrained by the range of body core temperature that is required to sustain living (see Figure 1).

The importance of body tissue insulation in maintaining internal heat balance is well described in classical thermophysiological litera-ture,5 and it is a crucial factor in all thermophysiological models that

simulate body temperatures for analyses of thermal environments.6,7

Body tissue insulation is determined by body composition (ie, muscle- ,

Received: 20 September 2016 

|

  Accepted: 4 February 2017 DOI: 10.1111/ina.12372

O R I G I N A L A R T I C L E

Evaluating the performance of thermal sensation prediction

with a biophysical model

M. Schweiker

1,2

 | B. R. M. Kingma

3,4

 | A. Wagner

1

MS and BRMK Authors contributed equally to this publication.

1Faculty of Architecture, Building Science

Group, Karlsruhe Institute of Technology, Karlsruhe, Germany

2Heidelberg Academy of Sciences and

Humanities, Heidelberg, Germany

3Department of Human Biology, NUTRIM

School of Nutrition and Translational Research in Metabolism of Maastricht University Medical Centre+, Maastricht, The Netherlands

4Department of Mechanical

Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands Correspondence

Marcel Schweiker, Karlsruhe Institute of Technology, Building Science Group, Karlsruhe, Germany.

Email: marcel.schweiker@kit.edu

Abstract

Neutral thermal sensation is expected for a human body in heat balance in near- steady- state thermal environments. The physiological thermoneutral zone (TNZ) is defined as the range of operative temperatures where the body can maintain such heat balance by actively adjusting body tissue insulation, but without regulatory in-creases in metabolic rate or sweating. These basic principles led to the hypothesis that thermal sensation relates to the operative temperature distance from the thermoneu-tral centroid (dTNZop). This hypothesis was confirmed by data from respiratory climate chamber experiments. This paper explores the potential of such biophysical model for the prediction of thermal sensation under increased contextual variance. Data (798 votes, 47 participants) from a controlled office environment were used to analyze the predictive performance of the dTNZop model. The results showed a similar relationship between dTNZop and thermal sensation between the dataset used here and the previ-ously used dataset. The predictive performance had the same magnitude as that of the PMV model; however, potential benefits of using a biophysical model are discussed. In conclusion, these findings confirm the potential of the biophysical model with regard to the understanding and prediction of human thermal sensation. Further work re-mains to make benefit of its full potential.

K E Y W O R D S

biophysical model, indoor temperature, performance evaluation, prediction, thermal comfort, thermal sensation

(3)

fat tissue and morphology) and is adjusted through muscle blood flow and skin blood flow. Nota bene, in resting conditions 90% of body tissue insulation is determined by low- perfused muscle tissue,8,9 and

higher appendicular muscle mass is associated with lower overall body tissue insulation.10

Several attempts have been made to include body tissue insu-lation in simple steady- state heat balance models.11,12 For instance,

Humphreys used the approach to rationally describe how metabolic rate and body tissue insulation influence the globe temperature re-quired for thermal balance (see Figure 2).11 With body tissue insulation

ranging between 0.03 m2K/W and 0.12 m2K/W, Humphreys assumed

the mid- region of body tissue insulation (0.04- 0.09 m2K/W) to be

as-sociated with thermal comfort.

Later, Kingma et al.12 independently considered the whole range

of body tissue insulation and concluded that indeed the mid- region of body tissue insulation is associated with thermal comfort by cross- referencing comfort- associated skin temperatures from experimental studies.

For a given metabolic rate, skin wettedness, and body core temperature, the body tissue insulation level dictates the range of skin temperatures that support thermal balance. The center of this skin temperature range corresponds to the center range of body tissue insulation, and consequently, body tissue insulation depends on the environmental conditions that support external thermal balance.

The physiological thermoneutral zone (TNZ) is defined as the range of operative temperatures where the body can maintain thermal bal-ance, without regulatory increases in metabolic rate or sweating (see Figure 3).13 Within this temperature range, the body actively adjusts

body tissue insulation by skin blood flow regulation (body tissue insu-lation is increased by vasoconstriction and decreased by vasodiinsu-lation). The center of the physiological thermoneutral zone thus also coincides with the center range of body tissue insulation.

Above- described basic principles related to human thermoregu-lation have led the authors to test and confirm the hypothesis that thermal sensation relates linearly to the distance of operative tem-perature from the thermoneutral centroid (dTNZop); see Figure 4 for a schematic view of thermal sensation vs. dTNZop.14,15

This analysis was based on data from 16 young adult female participants who performed light office work during a dynamic

temperature protocol in a combined climatic and respiratory cham-ber (for measurement of metabolic rate) at the Metabolic Research Unit Maastricht. The thermoneutral centroid was calculated for the participants with a steady- state biophysical analysis. The re-sults indicated that 95% of the variation in average thermal sensa-tion was explained by the distance to the thermoneutral zone.14,15

However, the space for general interpretation is limited due to the small homogenous sample and low contextual variance (due to lab conditions and specific temperature protocol the participants were exposed to).

The aim of this paper is to evaluate the performance of the bio-physical analysis beyond a physiological laboratory setting, with data from a controlled office environment with increased contextual variance.

In relation to this aim, we posed the following research questions: • Is it possible to replicate the results of the biophysical analysis on

data from less controlled experiments?

• How good is the performance of using dTNZop for the prediction of thermal sensation?

• Which are influencing factors on the predictive performance?

2 | METHODS

The analysis in this study is performed by reusing data from studies on occupants’ behavior and thermal perception in the LOBSTER.16-18

The facility, participant characteristics, and experimental designs are shortly summarized; for details see aforementioned papers.

Practical Implications

• The presented model, based on a biophysical approach, can be highly beneficial for understanding and predicting thermal sensation in complex thermal environments. In addition, it offers the potential to base the prediction on individual characteristics such as age, sex, height, and weight.

F I G U R E   1   Schematic representation of internal and external heat balance model. From left to right, overall heat balance is satisfied when metabolic heat production equals heat loss. Internal heat balance is satisfied when core temperature is maintained and heat transport through the body equals heat loss. Likewise, external heat balance is satisfied when skin temperature is maintained and body heat loss equals metabolic heat production. Figure from Kingma & Marken- Lichtenbelt4

(4)

1014 

|

     SCHWEIKER Etal.

2.1 | The LOBSTER

The LOBSTER (Laboratory for Occupant Behaviour, Satisfaction, Thermal comfort, and Environmental Research) combines positive aspects of field studies and laboratory experiments as follows. First, indoor air and radiant conditions can be controlled via the ventila-tion systems and activated surfaces; on the one hand, these control options allow for comparable conditions within each study, and on the other hand, the variations in experimental designs and associated pre- defined thermal conditions led to a wide range of conditions over all studies considered for this paper. Second, participants are able to view the outdoors through real windows and are allowed to interact with the indoor and outdoor thermal environment by various means of control. The number and degree of controls can be varied according to the experimental design.

The facility houses two identical office rooms (24 m² of floor area, 3 m high). One of their walls is a post and beam façade of 4 m width including two operable windows (0.9 m width by 1.5 m high) and two

operable top light windows (0.9 m width and 0.5 m high). The glaz-ing is a triple glazglaz-ing (Ug=0.7 W/m2K, total solar transmittance=0.5);

the opaque balustrade is equipped with vacuum insulation panels (Upanel=0.2 W/m2K). The framing is of insulated aluminum (Uf=1.3 W/

m2K). The other exterior surfaces are made of a timber frame

construc-tion with wood fibers as insulaconstruc-tion material and U- values of 0.13 W/ m²K for the exterior walls, 0.12 W/m²K for the roof, and 0.12 W/m²K for the floor, which is elevated from the ground due to a rotating as-sembly underneath.

2.2 | Participants and experimental designs

In total 65 healthy adults (31 females, age: 25.5y±4.5, height: 175cm±8.8, weight: 72kg±15.5) participated in three experimental campaigns all conducted at warm outdoor conditions.17–19 The

par-ticipants were clothed according to the season (0.57clo±0.2) and per-forming light office work. All participants were asked to work on their own tasks for one, two, or three 8- hour working days starting from 9

am and including a 30- minutes lunch break. Depending on the

proto-col, they were allowed to tilt one or both windows, use the external Venetian blinds, adjust the lighting level, and/or use the ceiling fan (Table 1).

F I G U R E   2   Comfort zones (gray areas) for globe temperature vs. metabolic rate and varying clothing level according to Humphreys.11

The gray comfort bandwidths are a function of internal tissue insulation, external insulation (clothing), and metabolic rate. The copyright holder permitted reproduction of the figure provided the following message was included: “© BRE, reproduced with permission from CP 14/71 (1970). Note that the diagram shows historical data and might not represent current best practice”

F I G U R E   3   Schematic view of the thermoneutral zone (TNZ), which is situated between the lower critical temperature (LCT) and upper critical temperature (UCT). Below the LCT the body can maintain heat balance by metabolic regulation; above the UCT the body maintains heat balance via sweating. Within the TNZ heat balance is regulated via regulation of skin blood flow

F I G U R E   4   Thermal sensation vs. operative temperature. The scheme shows the concept that the distance to the thermoneutral center (dTNZop) scales linearly with thermal sensation. The position of the thermoneutral center point is a function of metabolic rate, range of tissue insulation, clothing, wind speed, and relative humidity

(5)

The participants work was interrupted by filling in comfort ques-tionnaires every 90 minutes on average for a total of six times a day. Among other questions, the comfort questionnaire consisted of the seven- point ASHRAE thermal sensation scale. The clothing level was assessed through a questionnaire at the beginning of the day. Changes in the clothing level were reported together with each comfort ques-tionnaire. In addition, physiological measures such as the skin tem-perature were monitored continuously at an interval of 1 minute.

Physical parameters indoors (air temperature, globe temperature, air velocity, relative humidity) and outdoors were measured in the middle of the room and logged in a 1- minute interval. The operative temperature was calculated according to ISO 7726:200120 using the

measurements of air temperature, globe temperature, and air veloc-ity. The states of windows, blinds, ceiling fans, and artificial lighting devices were logged in a 1- minute interval. Participants were allowed to use the restrooms upon necessity and to drink liquids at room tem-perature whenever they wished.

All studies were approved by the ethical committee and data pro-tection officer. Informed consent was signed by the participants prior to their participation.

2.3 | Biophysical model

The theoretical center of the TNZ is calculated based on the biophysi-cal model developed by Kingma et al.;12 see Figure 3 for a graphic

ex-ample of TNZ center. To calculate body core temperature, the model assumes a steady- state heat balance within the body and between the body and its environment (see Figure 1). The mathematical procedure is described in the Supplementary Information. Model variables are given in Table 2.

2.4 | Data preparation and description

In this study, the heat equivalent of activity level associated metabolic rate is scaled with individual body characteristics using the revised Harris & Benedict equation (H&B).21 The revised H&B equation

pre-dicts resting metabolic rate (~1 met) based on height, weight, gender,

and age. The empirical relation has a reasonable accuracy for average metabolic rate for populations where BMI ranges between 18 kg/m2

and 25 kg/m2, with an explained variance of 86%.21 To minimize the

influence of this prediction error to the analysis, the data points from participants with a body mass index >25 kg/m2 or <18 kg/m2 were

removed. In addition, five measurements from four participants were excluded based on regression diagnostics using the linear mixed ef-fect model described below (see eq. (5)). Therefore, the Cook’s dis-tance was calculated for each data point, which is a measure of the influence of the data point on the result.23 According to the literature,

data points associated with a Cook’s distance greater than 4/n, with n being the number of observations, can be regarded as highly influ-ential observations.24 Therefore, the five observations with a Cook’s

distance greater than 0.005 (4/800 observations) were removed. The remaining data consisted of 798 votes by 47 participants as summa-rized in Table 3.

For each measurement sample, i, the independent variable (dTNZop) was calculated according to the procedure described in the Supplementary Information using the R- package comf25 and

the assumptions presented in Table 2. In addition, PMV values were computed using the R- package comf25 and the same assumptions as

for calculation of dTNZop.

2.5 | Data analysis

After calculating dTNZop, the data were analyzed in four steps related to the three research questions presented in Introduction. Software package R26 was used throughout the analysis.

The first research question was approached in two ways:

First, we looked at a subset of the data to replicate the findings in Kingma et al.14 This subset was chosen to be as identical in its nature

as possible compared to the dataset used in their analysis. Therefore, only data from females participating in study A during condition A1, where they were placed in a single office, were used. The mean per voting timepoint±95% confidence interval was derived for actual (ob-served) thermal sensation votes (ASVs), predicted mean votes (PMVs), as well as aspects related to the perception of the thermal indoor T A B L E   1   Overview of campaigns and protocols included in dataset used for this paper

References Campaign identifier

Protocol identifier

Control option available

Persons per office

Window Blinds Lighting Ceiling fan

Schweiker & Wagner17 A A1 Yes Yes Yes Yes 1

A2 Yes Yes Yes Yes 2

A4 Yes Yes Yes Yes 4

Schweiker & Wagner18 W W1 Yes Yes Yes Yes 1

W2 Yes Yes Yes Yes 1

W3 Yes Yes Yes Yes 1

W4 Yes Yes Yes Yes 1

Schweiker & Wagner19 K K No No Yes Yes 1

(6)

1016 

|

     SCHWEIKER Etal.

environment. Next, the following linear regression model was fitted to the mean values of each voting timepoint:

The outcome of this regression analysis was used to calculate a predicted thermal sensation vote (PSV) for each measurement based on dTNZop through:

For the second way to approach the first research question, the complete dataset with individual measurements, ie, the 798 votes by 47 participants, was analyzed fitting an ordinal mixed effect logistic

regression model and a linear mixed effect regression model. Mixed effect models were used to account for the repeated votes (up to 18 times) of each participant.

The ordinal mixed effect logistic regression model was fitted, be-cause the ASVs were given on a categorical scale and do not neces-sarily comply with the assumptions of equidistance.27 For the ordinal

regression analysis, a cumulative link model with the logit function as link function was used.28 With a cumulative link model, the

probabil-ity, P, that an observation, i, falls in a response category, j, can be ex-pressed. The cumulative link mixed model used for this study denotes the probability of ASVi falling in category j of the seven categories of

the thermal sensation vote and can be expressed by: (1)

mean (ASVi) = β0+ β1mean (dTNZopi) + εi

(2)

mean (PSVi) = β0+ β1mean (dTNZopi)

(3)

logit (P(ASVij)) = θj− β1dTNZopi− υSubjecti

Description Symbol

Value or range (min–max) or mean

(min–max)±SD Unit

Activity Act 1.0- 1.2 MET

Resting metabolic rate Mbas 78.3 (62.6- 104.6)±11.1a,b W/m2

69.6 (64.3- 75.1)±3.3a,c

Respiratory heat loss

fraction arsp 0.08 Fraction

Tissue insulation Ibody 0.032- 0.112 m2 W/K

Body surface area A 1.8 (1.5- 2.3)±0.2d,b m2

1.7 (1.55- 1.87)±0.1d,c

Body core temperature Tc 36.5- 37.5 °C

Clothing insulation Icl e m2 W/K

Air velocity Vair e m/s

Relative humidity Rh e fraction

Lewis relation λ 2.2 °C/mmHg

Skin wettedness w 0.06 Fraction

aCalculated based on reported height, weight, age, and gender according to Roza & Shizgal21.

bFor complete dataset (see description in section 2.4).

cFor subset of data (see description in section 2.4).

dCalculated based on reported height and weight according to DuBois & DuBois22.

eBased on measurements during the experimental studies (see Table 3).

T A B L E   2   Model variables and values used in the biophysical model for this paper. Note that the values for clothing insulation, air velocity, and relative humidity are given in Table 3

Complete dataset Subset of dataseta

N (measurements) 798 83

N (participants) 47 (23 female) 14 (14 female)

Operative temperature (°C) 26.8 (22.3- 32.2)±1.8 27.3 (22.3- 30.9)±1.7

Relative humidity (%) 45.9 (24.5- 69.0)±8.0 43.4 (26.5- 62.0)±8.8

Air velocity (m/s) 0.23 (0- 0.94)±0.23 0.24 (0- 0.87)±0.23

Temperature change rate (K/h) 0.99 (−3.1 to 4.9)±0.99 1.1 (−1.4 to 4.2)±0.91

Running mean outdoor

temperature (°C) 24.9 (22.5- 26.4)±0.85 24.7 (22.5- 26.3)±1.0

Clothing level (CLO) 0.55 (0.23- 0.97)±0.16 0.53 (0.23- 0.93)±0.17

Body mass index (kg/m2) 22.1 (18.3- 24.9)±1.6 21.7 (18.3- 24.9)±1.7

Age (years) 24.3 (18- 29)±2.5 24.4 (20- 28)±1.8

aSee description in the following section 2.4.

T A B L E   3   Descriptive statistics of the dataset used. If applicable, the format is (mean (min- max)±SD). Note that only the measurements at the times of the votes were considered here

(7)

where i is the index of the measurement, j the category of the thermal sensation vote, and θj the intercept of category j. υSubject represents

the random effects imposed by the participants’ individuality.

P- values were obtained by likelihood ratio tests of the model

pre-sented in eq. (3) with the effect of dTNZop against the model with-out dTNZop. R- package ordinal28 with function clmm was used for this

analysis.

For an easier interpretation of the result, predicted probabilities will be obtained and presented for each category through:

The probability that a participant votes cool on the thermal sensa-tion scale given a specific value of dTNZop can be calculated by:

The linear mixed effect regression analysis was included to com-pare the results with ordinal regression analysis. Should the distance between the linear mixed effect regression analysis and the ordinal regression analysis be small, the coefficients of the linear mixed effect regression analysis could be compared to coefficients presented by Kingma et al.14 The following linear mixed effect regression model was

fitted to the dataset with individual measurements:

P- values were obtained by likelihood ratio tests of the model pre-sented in eq. (6) with the effect of dTNZop against the model with-out dTNZop. R- package lme429 with function lmer was used for this

analysis.

For the second research question, the coefficients derived with the linear mixed effect regression analysis were used to predict the thermal sensation based on dTNZop by:

The resulting values of PSV were categorized to PSVcat to be

com-parable with the values of ASV, which were given on a categorical scale. For the categorization, all PSVs with values below or equal −2.5 were categorized to be −2, PSVs above −2.5 and below or equal −1.5 as −1, and so on. The same procedure was applied to the values of PMV to create the variable PMVcat. The performance of ASV, PSVcat, and PMVcat was then assessed through the following four

perfor-mance criteria:

First, the root mean square error is, eg, given by

with n being the number of votes.

Second, the average accuracy30 was calculated by

With j, the number of categories, ie, in case of the thermal sen-sation scale=7, and tp, tn, fn, and fp, the number of true positives,

true negatives, false negatives, and false positives of the correspond-ing category. To give an example, the number of true positives in the category warm is the number of votes observed and predicted as warm, while the number of true negatives is the number of votes ob-served and predicted as not warm, and the number of false negatives is the number of votes observed as warm, but predicted as not warm. Therefore, the average accuracy shows the average effectiveness per category, whereby the effectiveness of a category is the ratio of truly predicted votes to the total number of votes.

Third, the mean bias,31,32 ie, the mean difference between

pre-dicted and actual sensation vote, was calculated by

Fourth, the true positive rate,19 which is the proportion of the true

positive cases (TP), ie, those cases where ASV is equal to PSVcat or PMVcat, respectively, is given by

with n, the number of votes, and j, the number of categories of the thermal sensation scale.

All performance criteria except root mean square error were calcu-lated using R- package comf.25

The third research question was addressed looking at the differ-ence between ASV and PSV (the prediction error). First, this differdiffer-ence was plotted against

• indoor environmental parameters (operative temperature, relative humidity, air velocity, and temperature change rate during the last 10 minutes before the vote),

• the running mean outdoor temperature,33

• individual factors (clothing insulation level (CLO), sex, and body mass index (BMI)), and

• the session type related to differences in the type of controls and number of participants in the office. These were modeled as binary variables, ie, either being the session type in question (1) or not (0).

Second, a linear regression model and a linear mixed effect regres-sion model were fitted for each of these parameters. The fitted models were of the form:

where x is the parameter analyzed, eg, the operative temperature.

3 | RESULTS AND DISCUSSION

3.1 | Analysis of mean values per voting timepoint

This section presents and discusses the results based on the subset of data being as similar as possible with respect to sex and age of the sample as well as indoor environmental conditions to the dataset used by Kingma et al.14 (4) P(ASVj) = 1 1 + e−(θj− β1dTNZop) (5) P(cool) = 1 1 + e−(θcool− β1dTNZopi) (6) ASVi= β0+ β1dTNZopi+ υSubjecti+ εi (7) PSVi= β0+ β1dTNZopi (8)

root mean square error = �

n

i=1( PSVcat− ASV) 2 n , (9) average accuracy = ∑j i=1 tpi+tni tpi+fn i+fpi+tni j , (10)

mean bias = mean (PSVi− ASVi)

(11)

true positive rate = ∑j i=1TPj n , (12) (ASVi− PSVi) = β0+ β1xi+ εi (13) (ASVi− PSVi) = β0+ β1xi+ υSubjecti+ εi.

(8)

1018 

|

     SCHWEIKER Etal. Linear regression analysis on means for all six voting timepoints

showed no significant relation at P<.05 between actual thermal sen-sation votes (ASVs) and calculated dTNZop, but a tendency toward sig-nificance (β0 0.28±0.08 (standard errors), β1 0.18±0.07, P=.08, r2=.58).

For comparison, the relation between ASV and calculated PMV value was not significant (P=.19, r2=.39).

The outcome of this regression analysis was then used to calculate a mean predicted thermal sensation vote (PSV) for each voting time-point based on dTNZop (PSV dTNZop) according to eq. (2).

In Figure 4, the mean PSV (dTNZop) at each voting timepoint is shown together with the mean values of ASV and PMV (Fanger). The following can be observed from Figure 5:

• mean ASV at the second voting timepoint was low compared to mean PSV (dTNZop) and mean PMV (Fanger). Indoor environmen-tal conditions and clothing level did not suggest such decrease be-tween the first and third voting timepoint (Figure 5 right),

• from third to last voting timepoint, the course of mean ASV and mean PSV was parallel—with PSV being slightly below ASV, • mean PMV followed ASV for third and fourth voting timepoint, but

did not capture the dynamics of fifth and sixth voting timepoint, and • confidence intervals overlap in most cases, so that the differences

are not statistically significant.

The differences in the second, fifth, and sixth voting timepoint re-quire further discussion. The rather low mean ASV at the 2nd voting timepoint was neither predicted by the biophysical model presented in this study or the PMV model nor to be expected looking at the course of physical conditions. A possible explanation lies within the combination of experimental design and the type of thermal sensation scale used. The first voting timepoint was around 30 minutes after participants en-tered the controlled office environment of the test facility. At this point, participants’ metabolic rate can be expected to be still slightly elevated for those having arrived with the bicycle. In addition, stress level might have been slightly increased for those participating the first day, be-cause the environment was new to them. At the time of the second voting timepoint (105 minutes after entering the office), both, metabolic rate and stress level, can be expected to be decreased, because the par-ticipants were seated and doing non- stressful office work. At the same

time, thermal conditions did not change much, so that the participants might have perceived the office space to be slightly cooler than during the first voting timepoint, because of the decrease in internal heat gen-eration. When people feel differences, they prefer to report them by changing their vote on the given scale.34 In this study, they could change

their previous vote only by one category, because of the categorical scale used. Consequently, the second vote could have ended up much lower than expected. Further analyses going beyond the scope of this paper would be required to confirm or reject such assumptions.

The difference between mean ASV and mean PMV observed for the fifth and sixth voting timepoint is in line with previous findings, which showed that the PMV model underestimates the cooling effect of elevated air speeds.35

To address the question, whether the regression outcome pre-sented by Kingma et al.14 can be reproduced within a less controlled

environment, their results (preceded in the following by K16) will be compared with the results presented above (S16). The intercept (S16: 0.28±0.22 (CI) vs. K16: 0.18±0.21) is slightly higher in this study. The slope (S16: 0.18±0.07 vs. K16: 0.28±0.02) is slightly lower in this study. For intercept and slope, confidence intervals are overlapping, so that these differences are not significant.

3.2 | Analysis of individual measurements

In the following the results based on individual votes are presented. Ordinal mixed effect logistic regression analysis of ASV against dTNZop showed that dTNZop affected ASV (χ2(3)=210.3, P<.0001), with

an ordered log- odds estimate of about 0.75±0.08 (standard errors), and the cut- points between two categories, θ, of {(−2|−1)=−4.58±0.36, (−1|0)= −2.0±0.18, (0|1)=1.46±0.17, (1|2)=4.29±0.25, (2|3)=7.61±0.59}. The log- odds estimate can be interpreted in such a way that an increase in dTNZop by one unit would increase the log- odds of obtaining a ther-mal sensation vote in a higher category (ie, toward the hot end of the scale) by 0.75, the odds by 2.12 (=e0.75), and the probability by 0.68

(=2.12/(1+2.12)). For comparison, tossing a two- sided coin would have a probability of 0.50, odds of 1, and log- odds of 0.

The resulting predicted probabilities for each category for values of dTNZop between −4 and +4 are presented in Figure 6. The highest prob-ability of obtaining a neutral vote was related to a dTNZop around −0.2.

F I G U R E   5   Mean values and confidence intervals of sensation votes (left: ASV, actual sensation votes, PSV (dTNZop)

predicted sensation vote using the dTNZop model, PMV (Fanger) predicted mean vote by Fanger) and physical aspects of the indoor environment (right)

(9)

The linear mixed effect regression analysis on individual votes includ-ing the individual ASV as fixed effect and the participant code as random effect for intercept and slope revealed that dTNZop affected ASV signifi-cantly (χ2(3)=205.0, P<.0001). Intercept and slope of fixed effects resulted

in β0=0.08±0.04 and β1=0.23±0.02 (r2=.43). These coefficients were used

in the following to estimate PSV (dTNZop) by eq. (7). Testing a second- order polynomial model for the linear mixed effect regression between dTNZop and ASV showed no significant effect of the second- order polynomial.

To compare the results of ordinal and linear mixed effect analysis, the sum of the probabilities based on the ordinal regression model mul-tiplied with the value of each category was used for comparison with the linear mixed effect regression model. There was a very high correlation between the sum of probabilities and PSV based on linear mixed effect regression analysis (Pearson- r=.9996). Therefore, the following analyses are based on linear regression analyses despite ASV being ordinal.

3.3 | Performance evaluation

Table 4 presents the performance criteria for PSVcat—based on the coefficients obtained through linear mixed effect regression analysis described above—and PMVcat against the observed thermal sensa-tion votes (ASVs). Root mean square error and average accuracy are (nearly) the same, while the mean bias of PSVcat is slightly closer to 0 and its true positive rate is slightly higher; ie, PSVcat is performing slightly better for these two criteria. Nevertheless, both models— dTNZ and PMV—perform in the same magnitude.

3.4 | Influencing factors on prediction error

Prediction errors, ie, the difference between ASV and PSV, range be-tween −2.5 and +2.2 (mean: 0.03, SD: 0.73). Figure 7 shows the relation-ship between Top and the prediction error. The mixed effect regression

analysis with Top as predictor and the prediction error as outcome vari-able showed a statistically significant influence of Top on the prediction error (intercept: −0.98±0.6 (P<.05), slope: 0.038±0.02 (P<.05)). However, with an R2 value of .02, only 2% of the variance in the prediction error

was explained by the variations in Top. The small explained variance to-gether with the small slope showed that the prediction error caused by the dTNZ model is not systematically affected by Top.

In the Supplementary Information, the same analysis is presented for vapor pressure, air velocity, the temperature change rate during the last 10 minutes before the vote, the running mean outdoor tempera-ture, the clothing insulation level, body mass index, sex and experi-mental condition. Among these variables, only the slopes for clothing insulation level the session type, where participants were not allowed to open the windows (K), were significant at P<.01. The explained vari-ance was highest for the clothing insulation level with 6%.

The finding that the setting in which the participants were not al-lowed to open a window led to the warmest perception of compara-ble thermal conditions supports the findings of previous studies, that people tolerate warmer conditions when they have the opportunity to open the windows.36,37,39

In general, the prediction error was closest to 0, ie, a perfect fit, around those conditions presented in the data of Kingma et al.14: Top

~24- 26°C, AV <0.2, CLO ~0.5. The observation that there is a better fit at conditions within the thermoneutral zone suggests that thermal

F I G U R E   6   Probabilities for each category of sensation votes in relation to dTNZop

T A B L E   4   Performance criteria for PSVcat and PMVcat

PSVcat PMVcat

Root mean squared error 0.73 0.79

Average accuracy 0.84 0.84

Mean bias −0.03 0.11

True positive rate 52.6 50.6

F I G U R E   7   Residual analysis of prediction error for operative temperature (red: linear model, green dashed: mixed effect model (fixed effects), blue dotted: loess fit (1st degree, span 0.2))

22 24 26 28 30 32 –2 –1 01 2 Operative temperature (°C) ASV-PSV

(10)

1020 

|

     SCHWEIKER Etal. sensation is affected by more than a linear distance to the TNZ center

(eg, non- linear internal scaling of dTNZop). This may relate to the non- linear characteristic of temperature- sensitive neurons that are respon-sible for thermal reception.38 Nevertheless, regression coefficients are

very low for all these variables. These findings can be used to adjust the mapping of dTNZop to thermal sensation.

4 | GENERAL DISCUSSION

The results confirm the potential of the biophysical model to predict the thermal sensation of humans. In this study, the prediction performance of the dTNZop concept on average thermal sensation votes proved to be comparable to the current PMV standard and on individual level dTNZop significantly explains thermal sensation over a wide variety of contextual variances (r2=.43)—again comparable to the PMV model (r2=.41). The

main difference between both approaches is the inclusion of body tissue insulation in the biophysical model, which allows for calculation of the thermal condition with least internal thermal strain (ie, midpoint of body tissue insulation range). This study applied a population- averaged value for the range of body tissue insulation that yields comparable prediction to the PMV standard. To make more precise predictions, the body tissue insulation ranges of various subpopulations that differ in body composi-tion (muscle and fat mass) or ability to regulate skin blood flow could be included. For instance, the thickness of the subcutaneous fat layer posi-tively relates to body tissue insulation.9 Potential comparisons between

subpopulations could be, eg, lean vs. obese and males vs. females who differ in body composition, or young vs. old, and diabetic vs. non- diabetics who differ in ability to regulate skin blood flow. This type of analysis was not possible with the current dataset, and remains future work. It is also not certain that the addition of specific knowledge on body tissue insula-tion actually improves thermal sensainsula-tion predicinsula-tion because of the added uncertainty with an extra variable relative to the PMV model. However, exploring the influence of body tissue insulation seems worthwhile to pursue given that both PMV model and the dTNZop with averaged body tissue insulation values explain around 50% of the variance in thermal sensation. The question is whether thermal sensation is indeed explain-able by heat balance only up to approximately 50% and to which level this can be improved by taking into account body tissue insulation.

Going beyond physiological factors to further increase the pre-dictive performance, the biophysical model presented here could also be combined with the framework for an adaptive thermal heat bal-ance model to account for physiological, behavioral, and psychologi-cal adaptive processes.19 In this context, it should be noted that this

paper showed the relationship between dTNZ and thermal sensation, but does not attempt to establish a relationship between dTNZ and thermal comfort. Such note is crucial, because it is possible that a non- neutral sensation or sweating is still perceived as comfortable depend-ing on the thermal experiences of the body. Such aspect is beyond the scope of this paper and to be investigated in the future.

Limitations in the applicability of these results lie in the uncertainty related to the values of clothing level and activity rate. In contrast to the procedure presented by Kingma et al.,14 these values were not

measured in the studies which the dataset used for this paper is based on. The clothing level was estimated from the participants’ answers using the classifications given in ISO 7730.3 These tabular values may

have led to real clothing insulation levels being higher or lower than those used for this analysis.

The activity level was assumed to be between 1.0 MET and 1.2 MET for this study, based on ASHRAE 55- 2013 and ISO 7730.1,3 However,

such assumption related to the activity level might capture neither all variations in activity level throughout the day nor other aspects affect-ing metabolic rate such as diet- induced thermogenesis (~10%) after the lunch break, or seasonal variations in metabolic rate.40-42 These

uncertainties might be able to explain part of the observed variance or, if systematic, alter the results. However, there is no more accurate procedure for assessing the exact clothing insulation value available except for detailed measurements of individual clothing garments worn by participants or the provision of standardized clothing items. As the former would be unfeasible to be conducted on a daily level for a number of participants and the latter would affect the general level of satisfaction, these procedures were not applied. As for the activity level, guidance would be necessary to which extent the metabolic rate increases during the day depending on activity and nutrition.

5 | CONCLUSIONS

This study confirms the linear relationship between the distance of operative temperature to the center of the thermoneutral zone (dTNZop) calculated based on a biophysical model and thermal sen-sation votes obtained by measurements within a variety of thermal conditions and contextual factors.

The results indicate that the performance of the biophysical model in predicting thermal sensation on average and on individual levels is of the same magnitude as that of the well- established PMV model. Both models predicted around 50% of the thermal sensation votes correctly, which is—with seven categories of thermal sensation—sig-nificantly better than a random guess. These findings point to the po-tential of the biophysical model with regard to the understanding and prediction of human thermal sensation.

For this study, the biophysical model was fed with population- averaged ranges for body tissue insulation. In the future, the biophysi-cal model and the relationship between dTNZop and thermal sensation may be tuned to specific subpopulations that differ in body compo-sition or ability for thermoregulation such as obese vs. non- obese, young vs. elderly. Such adjustment could lead to a higher performance of the biophysical model in predicting thermal sensation of specific subpopulations. At the same time, the question remains what part of thermal sensation is explained purely by physiology and heat balance and what part has to be explained by psychological factors.

REFERENCES

1. ASHRAE. Standard 55-2013. Thermal environmental conditions for human occupancy. Am Soc Heating, Refrig Air- Conditioning Eng Atlanta,

(11)

2. Fanger PO. Thermal Comfort Analysis and Applications in Environmental

Engineering. New York: McGraw-Hill; 1970.

3. ISO 7730. Ergonomics of the thermal environment: analytical deter-mination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. 2005. 4. Kingma BR, van Marken Lichtenbelt WD. Energy consumption in

build-ings and female thermal demand. Nat Clim Chang. 2015;5:1054-1056. 5. Burton AC, Edholm OG. Man in a Cold Environment. London: Arnold;

1955:273.

6. Fiala D, Lomas KJ, Stohrer M. A computer model of human thermo-regulation for a wide range of environmental conditions: the passive system. J Appl Physiol. 1999;87:1957-1972.

7. Gagge AP. Rational temperature indices of man’s thermal environ-ment and their use with a 2-node model of his temperature regula-tion. In: Federation Proceedings. Vol 32; 1973:1572.

8. Park YS, Rennie DW, Lee IS, et al. Time course of deacclimatization to cold water immersion in Korean women divers. J Appl Physiol. 1983;54:1708-1716.

9. Rennie DW. Tissue heat transfer in water: lessons from the Korean divers. Med Sci Sports Exerc. 1988;20(5 Suppl):S177-S184.

10. DeGroot DW, Havenith G, Kenney WL. Responses to mild cold stress are predicted by different individual characteristics in young and older subjects. J Appl Physiol. 2006;101:1607-1615.

11. Humphreys MA. A simple theoretical derivation of thermal comfort conditions. J Inst Heat Vent Eng. 1970;38:95.

12. Kingma BR, Frijns AJH, Schellen L, van Marken Lichtenbelt WD. Beyond the classic thermoneutral zone. Temperature. 2014;1:142-149. 13. Iups TC. Glossary of terms for thermal physiology. Third edition.

Revised by the commission for thermal physiology of the interna-tional union of physiological sciences (IUPS Thermal Commission).

Jpn J Physiol. 2001;51:245-280.

14. Kingma BR, Schweiker M, Wagner A, van Marken Lichtenbelt WD. Exploring the potential of a biophysical model to understand thermal sensation. In: Proceedings of 9th Windsor Conference: Making Comfort

Relevant Cumberland Lodge, Windsor, UK.; 2016.

15. Kingma BR, Schweiker M, Wagner A, van Marken Lichtenbelt WD. Exploring the potential of a biophysical model to under-stand thermal sensation. Build Res Inf. 2017; doi: 10.1080/ 09613218.2017.1299996.

16. Schweiker M, Brasche S, Hawighorst M, Bischof W, Wagner A. Presenting LOBSTER, an innovative climate chamber, and the anal-ysis of the effect of a ceiling fan on the thermal sensation and per-formance under summer conditions in an office-like setting. In:

Proceedings of 8th Windsor Conference: Counting the Cost of Comfort in a Changing World Cumberland Lodge, Windsor, UK.; 2014:924-937.

17. Schweiker M, Wagner A. The effect of occupancy on perceived control, neutral temperature, and behavioral patterns. Energy Build. 2016;117:246-259.

18. Schweiker M, Wagner A. The effect of thermal inertia on office work-ers subjective and physiological responses; and performance under summer conditions. Energy Procedia. 2015;78:2953-2958.

19. Schweiker M, Wagner A. A framework for an adaptive thermal heat balance model (ATHB). Build Environ. 2015;94:252-262.

20. ISO 7726. Ergonomics of the thermal environment, instruments for measuring physical quantities. Geneva Int Stand Organ. 1998. 21. Roza AM, Shizgal HM. The Harris Benedict equation reevaluated:

resting energy requirements and the body cell mass. Am J Clin Nutr. 1984;40:168-182.

22. Du Bois D, Du Bois EF. A formula to estimate the approximate surface area if height and weight be known. 1916. Nutrition. 1989;5:303. 23. Cook RD. Detection of influential observation in linear regression.

Technometrics. 1977;19:15-18.

24. Bollen KA, Jackman RW. Regression diagnostics: an expository treat-ment of outliers and influential cases, In: Fox J, Long JS, eds. Modern

Methods of Data Analysis. Newbury Park, CA: Sage; 1990:257-291.

25. Schweiker M, Mueller S, Kleber M, Kingma BR, Shukuya M. comf: Functions for Thermal Comfort Research. R package version 0.1.7. 2016. https://cran.r-project.org/package=comf. Accessed January 26, 2017. 26. R Development Core Team. R: A Language and Environment for

Statistical Computing. Vienna, Austria: R Foundation for Statistical

Computing, Vienna, Austria; 2012.

27. Schweiker M, Fuchs X, Becker S, et al. Challenging the assumptions for thermal sensation scales. Build Res Inf. 2016. doi:10.1080/096132 18.2016.1183185.

28. Christensen RHB. ordinal—Regression Models for Ordinal Data. R package version 2015.6-28. 2015. http://www.cran.r-project.org/ package=ordinal/. Accessed January 26, 2017.

29. Bates DM, Maechler M, Bolker B. lme4: Linear Mixed-Effects Models

Using S4 Classes. R package version 0.999999-0; 2012.

30. Sokolova M, Lapalme G. A systematic analysis of performance mea-sures for classification tasks. Inf Process Manag. 2009;45:427-437. 31. Humphreys MA, Nicol F. The validity of ISO- PMV for predicting

comfort votes in every- day thermal environments. Energy Build. 2002;34:667-684.

32. Schweiker M, Wagner A. Exploring potentials and limitations of the adaptive thermal heat balance framework. In: Proceedings of 9th

Windsor Conference: Making Comfort Relevant Cumberland Lodge, Windsor, UK.; 2016.

33. CEN 15251. Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics; German version EN 15251:2012. August 2012.

34. McIntyre DA. Indoor Climate. London: Applied Science Publisher; 1980. 35. Huang L, Arens EA, Zhang H, Zhu Y. Applicability of whole- body heat

balance models for evaluating thermal sensation under non- uniform air movement in warm environments. Build Environ. 2014;75:108-113. 36. Schweiker M, Brasche S, Bischof W, Hawighorst M, Voss K, Wagner A.

Development and validation of a methodology to challenge the adap-tive comfort model. Build Environ. 2012;49:336-347.

37. Brager GS, Paliaga G, de Dear RJ. Operable windows, personal con-trol, and occupant comfort. ASHRAE Trans. 2004;2:17-35.

38. Kingma BRM, Vosselman MJ, Frijns AJH, van Steenhoven AA, van Marken Lichtenbelt WD. Incorporating neurophysiological concepts in mathe-matical thermoregulation models. Int J Biometeorol. 2014;58:87-99. 39. Hellwig RT, Brasche S, Bischof W. Thermal Comfort in Offices -

Natural Ventilation vs. Air Conditioning. In: Proceedings of Conference:

Comfort and Energy Use in Buildings - Getting Them Right, Cumberland Lodge, 27-30th April 2006. London: Network for Comfort and Energy Use in Buildings. Windsor, UK; 2006.

40. Westerterp KR. Diet induced thermogenesis. Nutr Metab (Lond). 2004;1:1.

41. Van Ooijen AMJ, van Marken Lichtenbelt WD, Van Steenhoven AA, Westerterp KR. Seasonal changes in metabolic and temperature re-sponses to cold air in humans. Physiol Behav. 2004;82:545-553. 42. Plasqui G, Westerterp KR. Seasonal variation in total energy

ex-penditure and physical activity in Dutch young adults. Obes Res. 2004;12:688-694.

SUPPORTING INFORMATION

Additional Supporting Information may be found online in the sup-porting information tab for this article.

How to cite this article: Schweiker M, Kingma BRM, Wagner A. Evaluating the performance of thermal sensation prediction with a biophysical model. Indoor Air. 2017;27:1012– 1021. https://doi.org/10.1111/ina.12372

Referenties

GERELATEERDE DOCUMENTEN

When you want people involved in the planning processes like participatory planning and citizens participation tries to do, it might be important to find out what they think of

Aangezien de meeste onderzoeken suggereren dat een lange klantrelatie de audit kwaliteit niet verlaagt, verwachten Knechel en Vanstraelen (2007) dat de kans dat een accountant

Dit laatste krijgt echter pas een goede toepasbaarheid wanneer de parameters niet alleen een relatief onderscheid tussen partijen kunnen leveren, maar ook in staat zijn om

Kennis over het aanleggen van een biotoop kwam in het beste geval neer op het gebruik van de juiste grondsoort, maar met de onderliggende grondopbouw werd nog

misschien niet deterministisch zijn laat onverlet dat strategisch en toegepast onderzoek concrete aanbeve- lingen, sturingsregels, methoden en technieken produ- ceert, waarvan

De leerlingen uit de diverse landen waren echter zo enthousiast dat alle landen niet alleen de opdracht hebben gemaakt die ze moesten maken, maar ook alle andere

Publisher’s PDF, also known as Version of Record (includes final page, issue and volume numbers) Please check the document version of this publication:.. • A submitted manuscript is