A FEASIBILITY STUDY IN MEASURING SOFT TISSUE ARTIFACTS ON THE UPPER LEG USING INERTIAL AND MAGNETIC SENSORS

Dirk Weenk*, Alien G. Stevens, Bart H.W. Koning, Bert-Jan F. van Beijnum, Hermie J. Hermens and Peter H. Veltink

*University of Twente, Faculty of EEMCS, Biomedical Signals and Systems P.O. Box 217, 7500 AE Enschede, The Netherlands.

e-mail: d.weenk@utwente.nl

Web page: http://www.utwente.nl/ewi/bss/

ABSTRACT

Soft-tissue artifacts cause inaccurate estimates of body segment orientations. The inertial sensor (or optical marker) is orientating (or displacing) with respect to the bone it has to measure, due to muscle and skin movement [1].

In this pilot study 11 inertial and magnetic sensors (MTw, Xsens Technologies) were placed on the rectus femoris, vastus medialis and vastus lateralis (upper leg). One sensor was positioned on the tendon plate behind the quadriceps (iliotibial tract, as used in Xsens MVN [1]) and used as reference sensor. Walking, active and passive knee extensions and muscle contractions without flexion/extension were recorded using one subject. The orientation of each sensor with respect to the reference sensor was calculated. During walking, relative orientations of up to 28.6º were measured (22.4±3.6º). During muscle contractions without flexion/extension the largest relative orientations were measured on the rectus femoris (up to 11.1º) [2].

This pilot showed that the ambulatory measurement of deformation of the upper leg is feasible; however, improving the measurement technology is required. We therefore have designed a new inertial and magnetic sensor system containing smaller sensors, based on the design of an instrumented glove for the assessment of hand kinematics [3]. This new sensor system will then be used to investigate soft-tissue artifacts more accurately; in particular we will focus on in-use estimation and elimination of these artifacts.

REFERENCES

[1] D. Roetenberg, H. Luinge, and P. Slycke, “Xsens MVN Technical Whitepaper: Full 6DOF Human Motion Tracking Using Miniature Inertial Sensors”, 2009

[2] A.G. Stevens, “Measuring the deformation of the m. quadriceps femoris with inertial and magnetic measurement units”, Bachelor thesis, University of Twente, 2012

[3] H.G. Kortier, H.M. Schepers, V.I. Sluiter, and P.H. Veltink, “Ambulatory Assesment of Hand Kinematics, using an instrumented glove”, Proceedings of XII International Symposium on 3D Analysis of Human Movement, 18-29 July 2012, Bologna, Italy. pp. 15-18, Universita di Bologna

Referenties

GERELATEERDE DOCUMENTEN

We have found that depending on the transparency of the SIs tunnel barrier, the decrease in the s-layer thickness leads to transformation of the CPR shape going in the two

The Western Cape Education Language Act (Western Cape Province, 1998) recognises three official languages, namely English, Afrikaans and isiXhosa that can be used as a lan­ guage

derived from the theoretical application of the case study of the interaction between Europol and volunteers in the ‘Save a Child – Trace an Object’ project to the governance model of

Once the EU’s traditional stakeholders of the smart grid were identified, it allowed to identify emerging actors within the smart grid ecosystem and that were related to GET as well

Such an approach would, for any particular blood matching strategy, allow balancing the costs of donor recruitment, donor typing, inventory management, blood product logistics,

A conceptual process design was made for the delignification of lignocellulosic biomass using a deep eutectic solvent comprised of lactic acid and choline chloride.. Mass and energy

An extensive mediation analysis then helps to provide insight in and allows for anticipation on potential effects of technology on users and value dynamics, something that

The SPaQ is capable of measuring the dynamic magnetization curve of SPIONs at low field strengths and frequencies between 1 and 10 kHz. Therefore, it can give invaluable