• No results found

Innovation in nuclear medicine instrumentation: looking back and moving forward

N/A
N/A
Protected

Academic year: 2021

Share "Innovation in nuclear medicine instrumentation: looking back and moving forward"

Copied!
3
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

University of Groningen

Innovation in nuclear medicine instrumentation

Zaidi, Habib

Published in:

British journal of radiology DOI:

10.1259/bjr.20170871

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date: 2018

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

Zaidi, H. (2018). Innovation in nuclear medicine instrumentation: looking back and moving forward. British journal of radiology, 91(1081), [20170871]. https://doi.org/10.1259/bjr.20170871

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

BJR

Cite this article as:

Zaidi H. Innovation in nuclear medicine instrumentation: looking back and moving forward. Br J Radiol 2018; 91: 20170871.

https:// doi. org/ 10. 1259/ bjr. 20170871

Nuclear MediciNe Physics aNd iNstruMeNtatioN sPecial

feature editorial

innovation in nuclear medicine instrumentation: looking

back and moving forward

1,2,3,4habib Zaidi

1Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland 2Geneva University Neurocenter, University of Geneva, Geneva, Switzerland

3Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, Netherlands

4Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark

Address correspondence to: Prof Habib Zaidi E-mail: habib. zaidi@ hcuge. ch

Motivated by the widespread commercial availability of hy-brid SPECT/CT and PET/CT imaging and the challenges associated with the design and clinical adoption of hybrid SPECT/MRI and PET/MRI, we focus, in this special issue of BJR, on recent advances and future directions in nucle-ar medicine physics and instrumentation. During the last decade, tremendous efforts focused on addressing the chal-lenges encountered in the conceptual design of PET/MRI systems as well as improving their quantitative performance to achieve similar performance compared with standard PET/CT systems. With the introduction of solid-state pho-todetectors, such as avalanche photodiodes (APDs) and silicon photomultipliers (SiPMs), the challenges of poten-tial interference between PET and MRI components have now been to some extent sensibly addressed, thus paving the way toward compact fully integrated clinical PET/MRI systems with time-of-flight (TOF) capability. However, the technology is still in an embryonic state and its clinical role is yet to be established considering cost/benefit trafeoff. The number of scientific papers linked to the above topics has been expanding gradually, which spurred the compilation of comprehensive reviews in this special issue as a snapshot of the enthusiastically changing field of nuclear medicine technology.

The first paper in this special issue reviews the physical principles, technical developments in instrumentation and image reconstruction techniques that enabled the emer-gence of new clinical applications using SPECT/CT tech-nology (Ljungberg and Pretorius, doi; http:// dx. doi. org/ 10. 1259/ bjr. 20160402).1 This is followed by a comprehensive

overview of the major technical innovations in PET/CT systems, focusing primarily on TOF-PET technology, dual-tracer imaging, inline hadron therapy dose imaging and yttrium-90 imaging in the context of resin and glass micro-sphere liver radioembolizations (Walrand et al, doi; http://

dx. doi. org/ 10. 1259/ bjr. 20160534).2 Contrary to PET/CT,

which was predominately developed since its inception for clinical imaging, combined PET/MRI technology was initially driven by research in the preclinical field for imaging laboratory animals in the mid-1990s. The bulk of PET/MR research to date focused on building MR-compat-ible PET detectors and readout technologies, addressing the challenges of MRI-guided PET attenuation correction and motion compensation, and also finding a niche or primary clinical role for PET/MRI (Cabello and Ziegler; doi http:// dx. doi. org/ 10. 1259/ bjr. 20160363).3 Despite the

widespread interest in PET/MRI instrumentation, systems capable of clinical simultaneous SPECT/MRI are not avail-able yet to date. The challenges and ongoing efforts towards designing a dedicated prototype for clinical SPECT/MRI are discussed by Hutton et al (doi; http:// dx. doi. org/ 10. 1259/ bjr. 20160690).4

PET has, since its foundation, established itself as an important imaging modality enabling the quantitative assessment of molecular targets in vivo. PET quantifica-tion makes it possible to establish a link between the time-varying activity concentration in relevant organs/tissues and the fundamental parameters standing for the biological processes at the cellular level being assessed. The challenges associated with fully quantitative PET imaging is addressed in a detailed review focusing on recent efforts enabling not only to derive conventional PET metrics with higher accu-racy but also to design novel protocols and data processing techniques enabling the generation of whole-body para-metric images (Zaidi and Karakatsanis, https:// doi. org/ 10. 1259/ bjr. 20170508).5

There is no shortage of challenges and opportunities for the development of innovative nuclear medicine technologies and instrumentation. We hope that in this

Received:

16 November 2017 Accepted: 20 November 2017

© 2018 The Authors. Published by the British Institute of Radiology

(3)

2 of 2 birpublications.org/bjr Br J Radiol;91:20170871

BJR Zaidi

refereNces

1. Ljungberg M, Pretorius PH. SPECT/CT: an update on technological developments and clinical applications. Br J Radiol 2018; 91: 20160402. doi: https:// doi. org/ 10. 1259/ bjr. 20160402

2. Walrand S, Hesse M, Jamar F. Updateon novel trends in PET/CT technology and its clinical applications. Br J Radiol 2018; 91:

20160534: doi: https:// doi. org/ 10. 1259/ bjr. 20160534

3. Cabello J, Ziegler SI. Advances in PET/MR instrumentation and image reconstruction.

Br J Radiol 2018; 91: 20160363. doi: https:// doi. org/ 10. 1259/ bjr. 20160363

4. Hutton BF, Occhipinti M, Kuehne A, Máthé D, Kovács N, Waiczies H. Development

of clinical simultaneous SPECT/MRI. Br J

Radiol 2018; 91: 20160690. doi: https:// doi. org/ 10. 1259/ bjr. 20160690

5. Zaidi H, Karakatsanis N. Towards enhanced PET quantification in clinical oncology. Br J Radiol 2018; 91: 20170508. doi: https:// doi. org/ 10. 1259/ bjr. 20170508

limited space, we were able to give the readers of this issue a flavour of recent developments in the field and their poten-tial applications in clinical and research settings in the future. The compilation of this special issue was truthfully gratifying and hope that the readers find the contents of value in their research.

ackNowledgeMeNts

The Guest Editor is especially grateful to the authors who have contributed to this special issue, as well as the reviewers for their valuable comments and suggestions. He would also like to thank Tami Potten (BIR, London) for her support and patience in bringing this issue to print.

Referenties

GERELATEERDE DOCUMENTEN

Volgens haar kunnen beide problemen met deze schakeling worden opgelost omdat de stroomkring niet verbroken wordt als één lampje stuk gaat.. Karin moet een keuze maken voor de

This thesis reports several methods investigated to pattern hydrogels on the microscale in closed microfluidic structures, and presents applications of these methods to

enforcing legislation to move SADC into a sustainable environment. 346 There is difficulty in establishing a balance between economic, social and environmental

De mening, tenslotte, dat het aantal niet-geërfde huislieden in de late middeleeuwen sterk toegenomen zou zijn (172, afb. 45), berust niet op 'harde' gegevens, maar op

The primary objective of this cohort study is to measure the frequency of self-reported gout attacks and the prevalence of tophi in patients diagnosed with gout in general practice,

This section will elaborate on the same institutional factors that have been elaborated upon in the case study on India, namely: (1) policies easing capital controls for

infrastructure, military capabilities, military power, military advantages, national interest, defend, protect, security, vital, crucial, critical, vulnerable. Secondly, in

Het min of meer inclusieve karakter, gekoppeld aan een zeker enthousiasme van de lagere sociale groepen, lijken daarom te rechtvaardigen dat de kunstacademie in het boek wordt