• No results found

Response to "Comment on 'MEMS-based high speed scanning probe microscopy"

N/A
N/A
Protected

Academic year: 2021

Share "Response to "Comment on 'MEMS-based high speed scanning probe microscopy""

Copied!
3
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

Response to "Comment on 'MEMS-based high speed scanning probe microscopy"

Disseldorp, E.C.M.; Tabak, F.C.; Katan, A.J.; Hesselberth, M.B.S.; Oosterkamp, T.H.; Frenken, J.W.M.; Spengen, W.M. van

Citation

Disseldorp, E. C. M., Tabak, F. C., Katan, A. J., Hesselberth, M. B. S., Oosterkamp, T. H., Frenken, J. W. M., & Spengen, W. M. van. (2010). Response to "Comment on 'MEMS-based high speed scanning probe microscopy". Review Of Scientific Instruments, 81(11), 117102.

doi:10.1063/1.3499235

Version: Not Applicable (or Unknown)

License: Leiden University Non-exclusive license Downloaded from: https://hdl.handle.net/1887/61308

Note: To cite this publication please use the final published version (if applicable).

(2)

Response to “Comment on ‘MEMS-based high speed scanning probe microscopy’” [Rev. Sci. Instrum. 81, 117101 (2010)]

E. C. M. Disseldorp, F. C. Tabak, A. J. Katan, M. B. S. Hesselberth, T. H. Oosterkamp, J. W. M. Frenken, and W.

M. van Spengen

Citation: Review of Scientific Instruments 81, 117102 (2010); doi: 10.1063/1.3499235 View online: http://dx.doi.org/10.1063/1.3499235

View Table of Contents: http://aip.scitation.org/toc/rsi/81/11 Published by the American Institute of Physics

(3)

Response to “Comment on ‘MEMS-based high speed scanning probe microscopy’” †Rev. Sci. Instrum. 81, 117101 „2010…‡

E. C. M. Disseldorp, F. C. Tabak,a兲 A. J. Katan, M. B. S. Hesselberth, T. H. Oosterkamp, J. W. M. Frenken,b and W. M. van Spengenc

Leiden University, Niels Bohrweg 2, 2333 CA Leiden, The Netherlands

共Received 2 July 2010; accepted 13 September 2010; published online 30 November 2010兲 关doi:10.1063/1.3499235兴

The comment adds valuable background information with respect to our paper1and further illustrates the impor- tance of MEMS scanners in various SPM applications as well as the ongoing development efforts in this field in dif- ferent research groups. The paper by Degertekin et al.2 de- scribes an interesting MEMS AFM scanner with readout and feedback. However, it also clearly states that “the device was not optimized for this experiment, and the sensor membrane acted as a lightly damped resonator rather than having a broadband frequency response that is ideal for fast interac- tion force measurements.” Although in Ref.3 Onaran et al.

discussed how their device could be employed as a high- speed scanning system, the measurement bandwidth was still as low as 10 kHz due to the limitations they already dis- cussed in Ref. 2. Whereas the mechanical resonance fre-

quency of the device was reported to be above 500 kHz, the maximum line rate that was actually demonstrated in the paper was very low, 60 Hz, and it was stated that “the imag- ing bandwidth of the FIRAT probe system controller was about 6 kHz, limited by the complex dynamics of the air flow in and out of the etch holes on two sides of the mem- brane.” In other words, although the high-speed possibilities have been recognized already in Refs. 2 and 3, they have definitely not been demonstrated in these publications.

We hasten to add that it is not at all straightforward to compare the speeds of scanning probe microscopes in terms of a single “figure of merit,” such as an image rate or a tip velocity. In order to conduct a meaningful comparison, we summarize the performances of high-speed MEMS scanning devices with feedback operation in the table below.

Publication Resonance frequency Frame rate Line rate Tip speed Comments

Onaran et al.共Ref.3 500 kHz 3.75 Hz 60 Hz 0.240 mm/s 16 lines per frame

Akiyama et al.共Ref.4 87 kHz 0.016 Hz 61 Hz 1.22 mm/s 256 lines per frame

Sarangapani et al.共Ref.5 420 kHz No image shown No image shown ⬎0.1 mm/s Force/time curves; 1 kHz measuement rate

Disseldorp et al.共Ref.1 218 kHz 2 Hz 1.024 kHz 5 mm/s 512 lines per frame

Yamashita et al.共Ref.6 70 kHz共feedback bandwidth兲 32.25 Hz 3,2 kHz 100 lines per frame; not MEMS scanning

Picco et al.共Ref.7 30 Hz 40 kHz Flexure stage; not MEMS scanning

Picco et al.共Ref.7 32 kHz/100 kHz 1300 Hz 130 kHz

No feedback; x-axis scanning by tuning fork oscillation

Rost et al.共Ref.8 ⬎64 kHz 200 Hz 1.131 kHz 0.3 mm/s No MEMS scanning; STM

1E. C. M. Disseldorp, F. C. Tabak, A. J. Katan, M. B. S. Hesselberth, T. H.

Oosterkamp, J. W. M. Frenken, and W. M. van Spengen, Rev. Sci. In- strum.81, 043702共2010兲.

2F. L. Degertekin, A. G. Onaran, M. Balantekin, W. Lee, N. A. Hall, and C.

F. Quate,Appl. Phys. Lett.87, 213109共2005兲.

3A. G. Onaran, M. Balantekin, W. Lee, W. L. Hughes, B. A. Buchine, R. O.

Guldiken, Z. Parlak, C. F. Quate, and F. L. Degertekin,Rev. Sci. Instrum.

77, 023501共2006兲.

4T. Akiyama, U. Staufer, and N. F. de Rooij,Appl. Phys. Lett.76, 3139 共2000兲.

5K. Sarangapani, H. Torun, O. Finkler, C. Zhu, and L. Degertekin,Eur.

Biophys. J.39, 1219共2009兲.

6H. Yamashita, N. Kodera, A. Miyagi, T. Uchihashi, D. Yamamoto, and T.

Ando,Rev. Sci. Instrum.78, 083702共2007兲.

7L. M. Picco, L. Bozec, A. Ulcinas, D. J. Engledew, M. Antognozzi, M. A.

Horton, and M. J. Miles,Nanotechnology18, 044030共2007兲.

8M. J. Rost, L. Crama, P. Schakel, E. van Tol, G. B. E. M. van Velzen- Williams, C. F. Overgauw, H. ter Horst, H. Dekker, B. Okhuijsen, M.

Seynen, A. Vijftigschild, P. Han, A. J. Katan, K. Schoots, R. Schumm, W.

van Loo, T. H. Oosterkamp, and J. W. M. Frenken,Rev. Sci. Instrum.76, 053710共2005兲.

a兲Electronic mail: tabak@physics.leidenuniv.nl.

b兲Electronic mail: frenken@physics.leidenuniv.nl.

c兲Electronic mail: w.m.vanspengen@tudelft.nl.

REVIEW OF SCIENTIFIC INSTRUMENTS 81, 117102共2010兲

0034-6748/2010/81共11兲/117102/1/$30.00 81, 117102-1 © 2010 American Institute of Physics

Referenties

GERELATEERDE DOCUMENTEN

Using the MEMS scanner, maximum tip speeds of 5 mm/s can be reached without inducing resonances in the MEMS z-scanner, nor are resonance frequencies of the mechanical loop excited

• Several new mining layouts were evaluated in terms of maximum expected output levels, build-up period to optimum production and the equipment requirements

To test this assumption the mean time needed for the secretary and receptionist per patient on day 1 to 10 in the PPF scenario is tested against the mean time per patient on day 1

In conclusion, this thesis presented an interdisciplinary insight on the representation of women in politics through media. As already stated in the Introduction, this work

In addition, in this document the terms used have the meaning given to them in Article 2 of the common proposal developed by all Transmission System Operators regarding

Linear plant and quadratic supply rate The purpose of this section is to prove stability results based on supply rates generated by transfer functions that act on the variables w

The strong decline of the inequality of wealth and of income in the Western world dur- ing the 20th Century – between 1910 and 1970, to be more precise – is, according to

Finally, in order to allow users to check the accuracy of their programs and their own inverse orthogonaliza- tion procedures, BHS list in Table V of their article the I =0, 1,