• No results found

University of Groningen Restorative dentistry done digitally Schepke, Ulf

N/A
N/A
Protected

Academic year: 2021

Share "University of Groningen Restorative dentistry done digitally Schepke, Ulf"

Copied!
15
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

Restorative dentistry done digitally

Schepke, Ulf

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from

it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date:

2018

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

Schepke, U. (2018). Restorative dentistry done digitally: Implementation and evaluation of some digital

tools in contemporary implant dentistry. Rijksuniversiteit Groningen.

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

CHAPTER

02

Osseointegration of a zirconia implant:

a case report and review

• PART A •

(3)

Abstract

The aim of this study was to describe the histological and histomorphometrical features of a retrieved, functional zirconia endosseous implant in a human subject and relate the findings to information available from literature on osseointegration in other explanted zirconia and titanium implants in man.

A maxillary zirconia implant in a 52-year old male patient (Zv3, Wolfratshausen, Germany) was retrieved and prepared for light microscopic evaluation. It had functioned successfully without objective or subjective concerns for approximately two years.

Histological examination demonstrated that most of the screw threads were filled with bone, showing a uniform colour, which was in close contact with the zirconia surface. No intervening fibrous tissue layer was observed between implant and the surrounding bone. In the calcified tissue many large rounded osteoblasts and osteocytes were visible. Bone contact measurements measuring from the most coronal aspect until the lowest thread revealed a mean percentage of bone to implant contact of 55.8% (SD 3.8%). This is comparable to findings regarding retrieved implants in the literature, although these show a wide range.

The histological data are coherent with a well osseointegrated zirconia implant after 2 years of functional loading. This provides further evidence of the potential of zirconia to osseointegrate to a more or less similar degree as titanium implants in man.

Osseointegration of a zirconia implant:

a case report and review

(4)

Introduction

Titanium (Ti) is seen as the ‘gold standard’ ground material for dental implants and has been widely and successfully used for decades. Nevertheless, it has some potential drawbacks, among which blue-greyish shimmering of the implant itself or implant components in cases of thin overlying

mucosa.1 Also, the high prevalence of peri-implant mucositis and peri-implantitis is of concern.2

Titanium has relatively little resistance against wear and fretting. Submicron titanium particles that can evolve from implant bending, induce inflammatory cytokines secretion in vitro and are

observed in soft tissues adjacent to sites with peri-implantitis.3,4 In addition, concerns regarding the

potential hypersensitivity towards titanium were raised which however, was seen in only a limited

number of susceptible patients.5 Therefore, some patients prefer a metal-free solution.

High strength ceramics such as Yttria-stabilized zirconiumdioxide (Y-TZP) could form an alternative for titanium as implant material. Y-TZP being white, entails better light dynamics, especially in cases with thin overlying mucosa. It can be milled according to individual specifications by means of a Computer Assisted Design and Computer Assisted Manufacturing (CAD-CAM) production

process. Both bone and soft tissues respond favourably to Y-TZP.6 In a 3-year retrospective study

clinical gingival parameters around zirconia implants compared to natural teeth demonstrated

less bleeding and smaller probing pocket depths around the implants.7 However peri-implantitis

and peri-implant mucositis were also reported for zirconia implants which did not always respond

favourably to treatment either.8 In a recent systematic review 19 clinical studies with zirconia

implants could be included. Most were biased because of methodological shortcomings, resulting in only a low evidence level. Nevertheless, the authors concluded that to date zirconia implants are

inferior to titanium implants in terms of implant survival.9 This is in agreement with a consensus

statement from a few years previously in which the use of Y-TZP implants was discouraged.10

Comparison of osseointegration between Y-TZP and Ti implants is almost exclusively done in animal studies. The results are consistent as comparable percentages of bone-implant contact between Ti and Y-TZP implants were reported in mandibles, maxillae and femur heads of rats, minipigs, dogs,

rabbits and goats.11-22 In one study in goats, multinucleated giant cells were seen in association with

zirconia and not with titanium implants, however, without a difference in the percentage of bone

contact.23

The aim of this case report is to describe the histomorphometrical and histological features of

a retrieved, functional zirconia implant in a human subject and relate the findings to the limited amount of information available from literature on osseointegration from other explanted implants.

CHAPTER 02 • P

AR

T

(5)

Materials and Methods

A zirconia (Y-TZP) implant (dimensions 5 mm wide x 11 mm long) in a 52-year old male patient at the position of the first upper right molar (ZV3, Wolfratshausen, Germany) was damaged and unsalvageable as a result of an intubation procedure necessary for unrelated treatment in general anaesthesia. The proximal crown of a natural abutment tooth was also injured. The implant was immobile and had functioned successfully without objective or subjective concerns for approximately two years. After informed consent was obtained, it was carefully retrieved using a trephine drill at low speed and copious cooling, including approximately 1 mm of surrounding alveolar bone. The specimen was stored in a cool place and eventually fixed in buffered formaldehyde (pH 7.4) 10% for 24 hours and subsequently dehydrated in ethanol.

After embedding in methylmethacrylate, following polymerization, three non-decalcified, 10-µm-thick, longitudinal sections of the implants were prepared in a plane parallel to the long

axis of the implant using a modified sawing microtome technique24 and subsequently stained with

methylene blue and basic fuchsin.

Light microscopical evaluation of all sections was executed using an automated Axio Imager Z1 microscope (Carl Zeiss Micro Imaging GmbH, Göttingen, Germany) at 10x as well as 200x magnification and consisted of a complete morphological qualitative description and quantitative analysis of the hard tissue response.

Results

At the time of retrieval, after having raised a muco-periosteal flap, the implant appeared clinically healthy and was fully surrounded by alveolar bone. Characteristic histological sections are presented as figures 1a-b.

Histological examination demonstrated that most of the screw threads were filled with bone, showing a uniform colour, which was in close contact with the zirconia surface. No intervening fibrous tissue layer was observed between implant and the surrounding bone. In the calcified tissue many osteocytes were visible.

Bone contact measurements were performed, measuring from the most coronal aspect until the lowest thread. The mean percentage of bone to implant contact as seen in the 3 sections was 55.8% (SD 3.8%), taken into consideration that coronally some alveolar bone seems to have been severed from the implant. This percentage of bone to implant contact lies in the same range of magnitude or perhaps somewhat less than the percentages of bone to implant contact that have been reported in literature regarding human histology around implants with a titanium or hydroxyapatite surface (table 1).

(6)

Figure 1a

Characteristic histological section showing intimate contact between the zirconia implant (gray) and the red colored adjacent bone (magnification 10x).

Figure 1b

Histological section; the depicted area (see framework in picture 1a) emphasizes the intimate contact between the zirconia implant (gray) and the red colored bone (magnification 200x). The vital bone is bounded by osteoblasts.

CHAPTER 02 • P

AR

T

A

(7)

Table 1 Studies in

volving human hist

ology r egar ding den tal implan ts in r ela tion t o the cur ren t study Study N Lo ca tion Ty pe Reason f or Retrie val Years Bone t o implan t c on tac t (%) Zir conia Nevins et al , 2011 26 1 M axilla Y-TZP Planned 0.5 Not pr ovided Kohal et al , 2016 25 19 M andible Y-TZP Per i-implan titis 4.1 76.4% (r ange 58.1–93.7%,SD 9.7%) 3 M axilla Y-TZP Per i-implan titis 4.5 77.2% (r ange 73.6-81.9%,SD 4.3%) Curr en t study 1 M axilla Y-TZP Fr ac tur e 2 55.8% (SD 3.8%) HA -c oat ed D ominici et al , 1997 27 1 M andible HA -c oa ted Post -mor tem 3 75.3% Rohr er et al , 1999 28 2 M axilla HA -c oa ted Post -mor tem 3 47% Romanos et al , 2005 29 3 M andible HA -c oa ted In func tion 0.5 80.6% Tr isi et al , 2005 30 2 M andible HA -c oa ted Post -mor tem 10 37.6% Iezzi et al , 2007 31 2 M axilla HA -c oa ted Fr ac tur e abutmen t 14 28%-60% Iezzi et al , 2009 32 1 M andible HA -c oa ted Fr ac tur e 15 77.6% (SD 5.1%) Coelho et al , 2010 33 30 M

axilla and mandible

HA -c oa ted Pr osthetic r easons 0.2-13 35%-95% Iezzi et al , 2013 34 1 M andible HA -c oa ted Per i-implan titis 10 36.3% (SD 1.2%) Titanium Dominici et al , 1997 27 1 M andible Ti Post -mor tem 3 72.2% Rohr er et al , 1999 28 5 M andible Ti Post -mor tem 7 65% D eg idi et al , 2003 35 11 M

axilla and mandible

Ti In func tion 10/12 60%-65% Roc ci et al , 2003 36 2

Class III / IV bone

O xidiz ed T i In func tion 0.5 84.9% (SD 0.9%) 6

Class III / IV bone

O xidiz ed T i In func tion 0.5 81.4% (SD 10.6%) Bolind et al , 2005 37 216 M

axilla and mandible

Ti Var ious r easons 0.3-16 75% Romanos et al , 2005 29 16 M axilla Ti In func tion 0.6 62.4% 10 M andible Ti In func tion 0.4 66.8% Coelho et al , 2009 38 23 M

axilla and mandible

Ti Pr osthetic r easons 8-13 62.2% D eg idi et al , 2011 39 9 M

axilla and mandible

Ti In func tion 0.1 59.9% Iezzi et al , 2012 40 2 M andible Ti A butmen t fr ac tur e 5 89.8% 1 M axilla Ti A butmen t fr ac tur e 5 76.6% Iezzi et al , 2014 41 8 M

axilla and mandible

Ti Pr osthetic/psy cholog ic 5-22 94-100% M angano et al , 2015 42 1 M andible Ti Fr ac tur e 5 47.2% 1 M axilla Ti Fr ac tur e 10 NR

(8)

Discussion

Little information is available with respect to the osseointegration of zirconia implants in humans. The best indication of their potential for osseointegration is obtained from animal studies or compromised situations (i.e. retrieval after peri-implantitis). Therefore, the current observations are of interest. The clinical performance of the particular implant type in the present study was described in a retrospective evaluation involving 74 patients, 121 implants, which observation time stretched up to 3 years. Implant survival was 96.5% with healthy peri-implant conditions, both clinically and

radiographically.7 It is a 2-piece implant (figure 2) with a surface roughness with a Ra of 20-40 µm that

is accomplished by blasting with zirconia grid before sintering (figures 3a-b). Figure 2

Zv3 standard implant with a prepared glass fiber post (Wolfratshausen, Germany, bottom) and an implant with a personalized epi-gingival profile and unprepared glass fiber post (top).

The histological and histomorphometric data associated with the retrieved implant demonstrate a well osseointegrated, zirconia implant, concurrent with a healthy situation, ample bone to implant contact and no apparent signs of fibrous or granulomatous tissues adjacent to the implant after 2 years of clinical functional loading.

CHAPTER 02 • P

AR

T

A

(9)

the apical regions and state that the remaining bone that was attached to the implants contained a regular lamellar structure with osteons and osteocytes. Approximately 20% more bone to implant contact was observed compared to the present findings, despite the compromised condition that had required removal of the implants. This may be because of individual variation. However, the retrieved implants by Kohal et al were mostly mandibular implants for which a higher bone to implant percentage may be anticipated than for a maxillary implant. The current study evaluated only a single maxillary implant.

Figure 3a

REM image of the Zv3 implant surface.

Figure 3b

(10)

In another study a female patient agreed to have a maxillary 2-piece zirconia implant (Ziterion,

Ziterion GMBH) and to have it removed after 6 months for histological evaluation.26 It was not been

functionally loaded. There were no signs of implant mobility. Both light microscopy and back scatter electron microscopy were performed. Histological analysis revealed close bone apposition with the combination of newly formed and native bone, with areas of mineralized bone contact to the implant surface as well as areas where bone marrow spaces were adjacent to the implant surface. No quantitative data with respect to the amount of bone-to-implant contact were presented and the

authors state that they ‘expect it to be sufficient for clinical service, but not as strong as expected’.26

Information with respect to the implant surface was not provided in the article.

The human studies providing evidence of ossseointegration of titanium and HA-coated implants report a wide range of percentages of bone-to-implant contact and the data from the present study lie in that range (table 1).

The histological data presented in this case report are coherent with a well osseointegrated zirconia implant after 2 years of functional loading. It is concluded that the observations from the retrieved implant in this study provide further evidence of the potential of zirconia to osseointegrate to a more or less similar degree as titanium implants in man.

Acknowledgements

The work was supported by the authors’ institutions. The authors confirm that there are no known conflicts of interest associated with this publication and there has been no significant financial support for this work that could have influenced its outcome.

CHAPTER 02 • P

AR

T

A

(11)

References

1. Jung RE, Sailer I, Hammerle CH, Attin T, Schmidlin P. In vitro color changes of soft tissues caused by restorative materials. Int J Periodontics Restorative Dent. 2007;27(3):251-257.

2. Derks J, Schaller D, Hakansson J, Wennstrom JL, Tomasi C, Berglundh T. Effectiveness of implant therapy analyzed in a swedish population: Prevalence of peri-implantitis. J Dent Res. 2016;95(1):43-49.

3. Taira M, Kagiya T, Harada H, et al. Microscopic observations and inflammatory cytokine productions of human macrophage phagocytising submicron titanium particles. J Mater Sci Mater Med. 2010;21(1):267-275.

4. Wilson TG,Jr, Valderrama P, Burbano M, et al. Foreign bodies associated with peri-implantitis human biopsies. J Periodontol. 2015;86(1):9-15.

5. Siddiqi A, Payne AG, De Silva RK, Duncan WJ. Titanium allergy: Could it affect dental implant integration? Clin Oral Implants Res. 2011;22(7):673-680.

6. Manicone PF, Rossi Iommetti P, Raffaelli L, et al. Biological considerations on the use of zirconia for dental devices. Int J Immunopathol Pharmacol. 2007;20(1 Suppl 1):9-12.

7. Brull F, van Winkelhoff AJ, Cune MS. Zirconia dental implants: A clinical, radiographic, and microbiologic evaluation up to 3 years. Int J Oral Maxillofac Implants. 2014;29(4):914-920.

8. Schwarz F, John G, Hegewald A, Becker J. Non-surgical treatment of peri-implant mucositis and peri-implantitis at zirconia implants: A prospective case series. J Clin Periodontol. 2015.

9. Depprich R, Zipprich H, Ommerborn M, et al. Osseointegration of zirconia implants compared with titanium: An in vivo study. Head Face Med. 2008;4:30-160X-4-30.

10. Andreiotelli M, Wenz HJ, Kohal RJ. Are ceramic implants a viable alternative to titanium implants? A systematic literature review. Clin Oral Implants Res. 2009;20 Suppl 4:32-47.

11. Gahlert M, Gudehus T, Eichhorn S, Steinhauser E, Kniha H, Erhardt W. Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs. Clin Oral Implants Res. 2007;18(5):662-668.

12. Gahlert M, Rohling S, Wieland M, Sprecher CM, Kniha H, Milz S. Osseointegration of zirconia and titanium dental implants: A histological and histomorphometrical study in the maxilla of pigs. Clin Oral Implants Res. 2009;20(11):1247-1253.

13. Gahlert M, Roehling S, Sprecher CM, Kniha H, Milz S, Bormann K. In vivo performance of zirconia and titanium implants: A histomorphometric study in mini pig maxillae. Clin Oral Implants Res. 2012;23(3):281-286.

14. Hoffmann O, Angelov N, Gallez F, Jung RE, Weber FE. The zirconia implant-bone interface: A preliminary histologic evaluation in rabbits. Int J Oral Maxillofac Implants. 2008;23(4):691-695.

15. Hoffmann O, Angelov N, Zafiropoulos GG, Andreana S. Osseointegration of zirconia implants with different surface characteristics: An evaluation in rabbits. Int J Oral Maxillofac Implants. 2012;27(2):352-358.

(12)

16. Depprich R, Ommerborn M, Zipprich H, et al. Behavior of osteoblastic cells cultured on titanium and structured zirconia surfaces. Head Face Med. 2008;4:29-160X-4-29.

17. Kohal RJ, Wolkewitz M, Hinze M, Han JS, Bachle M, Butz F. Biomechanical and histological behavior of zirconia implants: An experiment in the rat. Clin Oral Implants Res. 2009;20(4):333-339.

18. Sennerby L, Dasmah A, Larsson B, Iverhed M. Bone tissue responses to surface-modified zirconia implants: A histomorphometric and removal torque study in the rabbit. Clin Implant Dent Relat Res. 2005;7 Suppl 1:S13-20.

19. Igarashi K, Nakahara K, Haga-Tsujimura M, Kobayashi E, Watanabe F. Hard and soft tissue responses to three different implant materials in a dog model. Dent Mater J. 2015;34(5):692-701.

20. Salem NA, Abo Taleb AL, Aboushelib MN. Biomechanical and histomorphometric evaluation of osseointegration of fusion-sputtered zirconia implants. J Prosthodont. 2013;22(4):261-267.

21. Aboushelib MN, Salem NA, Taleb AL, El Moniem NM. Influence of surface nano-roughness on osseointegration of zirconia implants in rabbit femur heads using selective infiltration etching technique. J Oral Implantol. 2013;39(5):583-590.

22. Thoma DS, Benic GI, Munoz F, et al. Histological analysis of loaded zirconia and titanium dental implants: An experimental study in the dog mandible. J Clin Periodontol. 2015;42(10):967-975.

23. Chappuis V, Cavusoglu Y, Gruber R, Kuchler U, Buser D, Bosshardt DD. Osseointegration of zirconia in the presence of multinucleated giant cells. Clin Implant Dent Relat Res. 2016;18(4):686-698.

24. van der Lubbe HB, Klein CP, de Groot K. A simple method for preparing thin (10 microM) histological sections of undecalcified plastic embedded bone with implants. Stain Technol. 1988;63(3):171-176.

25. Kohal RJ, Schwindling FS, Bachle M, Spies BC. Peri-implant bone response to retrieved human zirconia oral implants after a 4-year loading period: A histologic and histomorphometric evaluation of 22 cases. J Biomed Mater Res B Appl Biomater. 2016;104(8):1622-1631.

26. Nevins M, Camelo M, Nevins ML, Schupbach P, Kim DM. Pilot clinical and histologic evaluations of a two-piece zirconia implant. Int J Periodontics Restorative Dent. 2011;31(2):157-163.

27. Dominici JT, Olson JW, Rohrer MD, Morris HF. Postmortem histologic evaluation of hydroxyapatite-coated cylinder and titanium alloy basket implants in situ for 37 months in the posterior mandible. Dental implant clinical research group. Implant Dent. 1997;6(3):215-222.

28. Rohrer MD, Sobczak RR, Prasad HS, Morris HF. Postmortem histologic evaluation of mandibular titanium and maxillary hydroxyapatite-coated implants from 1 patient. Int J Oral Maxillofac Implants. 1999;14(4):579-586.

29. Romanos GE, Testori T, Degidi M, Piattelli A. Histologic and histomorphometric findings from retrieved, immediately occlusally loaded implants in humans. J Periodontol. 2005;76(11):1823-1832.

CHAPTER 02 • P

AR

T

A

(13)

31. Iezzi G, Scarano A, Petrone G, Piattelli A. Two human hydroxyapatite-coated dental implants retrieved after a 14-year loading period: A histologic and histomorphometric case report. J Periodontol. 2007;78(5):940-947.

32. Iezzi G, Orlandi S, Pecora G, Piattelli A. Histologic and histomorphometric evaluation of the bone response around a hydroxyapatite-coated implant retrieved after 15 years. Int J Periodontics Restorative Dent. 2009;29(1):99-105.

33. Coelho PG, Bonfante EA, Marin C, Granato R, Giro G, Suzuki M. A human retrieval study of plasma-sprayed hydroxyapatite-coated plateau root form implants after 2 months to 13 years in function. J Long Term Eff Med Implants. 2010;20(4):335-342.

34. Iezzi G, Malchiodi L, Quaranta A, Ghensi P, Piattelli A. Peri-implant bone response around a human hydroxyapatite-coated implant retrieved after a 10-year loading period: A case report. Int J Oral Maxillofac Implants. 2013;28(4):e190-4.

35. Degidi M, Scarano A, Petrone G, Piattelli A. Histologic analysis of clinically retrieved immediately loaded titanium implants: A report of 11 cases. Clin Implant Dent Relat Res. 2003;5(2):89-93.

36. Rocci A, Martignoni M, Burgos PM, Gottlow J, Sennerby L. Histology of retrieved immediately and early loaded oxidized implants: Light microscopic observations after 5 to 9 months of loading in the posterior mandible. Clin Implant Dent Relat Res. 2003;5 Suppl 1:88-98.

37. Bolind P, Johansson CB, Balshi TJ, Langer B, Albrektsson T. A study of 275 retrieved branemark oral implants. Int J Periodontics Restorative Dent. 2005;25(5):425-437.

38. Coelho PG, Marin C, Granato R, Suzuki M. Histomorphologic analysis of 30 plateau root form implants retrieved after 8 to 13 years in function. A human retrieval study. J Biomed Mater Res B Appl Biomater. 2009;91(2):975-979.

39. Degidi M, Perrotti V, Shibli JA, Novaes AB, Piattelli A, Iezzi G. Equicrestal and subcrestal dental implants: A histologic and histomorphometric evaluation of nine retrieved human implants. J Periodontol. 2011;82(5):708-715.

40. Iezzi G, Vantaggiato G, Shibli JA, et al. Machined and sandblasted human dental implants retrieved after 5 years: A histologic and histomorphometric analysis of three cases. Quintessence Int. 2012;43(4):287-292.

41. Iezzi G, Piattelli A, Mangano C, et al. Peri-implant bone tissues around retrieved human implants after time periods longer than 5 years: A retrospective histologic and histomorphometric evaluation of 8 cases. Odontology. 2014;102(1):116-121. 42. Mangano C, Piattelli A, Mortellaro C, Mangano F, Perrotti V, Iezzi G. Evaluation of peri-implant bone response in implants retrieved for fracture after more than 20 years of loading: A case series. J Oral Implantol. 2015;41(4):414-418.

(14)

CHAPTER 02 • P

AR

T

(15)

Referenties

GERELATEERDE DOCUMENTEN

Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners. Ender A, Attin

Degradation of yttria-stabilized zirconia dental implants abutments due to the tetragonal to monoclinic phase transformation was studied in detail by microstructural

Primary outcome measure was the relative reduction in mean fracture strength upon static loading between pairs of pristine zirconia abutments and abutments that had

Resin Nano Ceramic (RNC, Lava Ultimate, 3M ESPE, Seefeld, Germany) crowns were digitally manufactured and extraorally bonded to either a stock or a customized zirconia

The choice of restorative material for single crowns luted to zirconia implant abutments with an adhesive resin cement strongly influences the incidence of bonding failures after

Digital versus analog complete-arch impressions for single-unit premolar implant crowns: operating time and patient preference... Digital versus analog full-arch impressions

This randomized controlled clinical trial aims to study potential benefits of individualization of zirconia implant abutments with respect to preservation of marginal bone level

Another technological innovation is represented by CAD/CAM individualized zirconia implant abutments. The use of a stock abutment is a more conventional treatment modality, where the