From cardiogenesis to cardiac regeneration : focus on epicardium-derived cells

Winter, E.M.

Citation

Winter, E. M. (2009, October 15). From cardiogenesis to cardiac regeneration : focus on epicardium-derived cells. Retrieved from https://hdl.handle.net/1887/14054

Version: Corrected Publisher’s Version

License: Licence agreement concerning inclusion of doctoral thesis in the Institutional Repository of the University of Leiden

Downloaded from: https://hdl.handle.net/1887/14054

Note: To cite this publication please use the final published version (if applicable).

(2)

Winter EM1 *, Grauss RW2 *, Atsma DE2, Hogers B1, Poelmann RE1, van der Geest RJ3, Tschöpe C4, Schalij MJ2, Gittenberger-de Groot AC1, Steendijk P2

Left ventricular function in the post-infarct failing mouse heart by magnetic resonance imaging and conductance catheter: a comparative analysis

Acta Physiologica. 2008; 194(2): 111-122

7

(3)
(4)

Abstract

BackgroundMurine myocardial infarction (MI) models are increasingly used in heart failure studies. Magnetic resonance imaging (MRI) and pressure-volume loops by conductance catheter (CC) enable physiological phenotyping. We performed a comparative analysis of MRI versus CC to assess left ventricular (LV) function in the failing mouse heart.

Methods

MI was created by LAD ligation. MRI (day14) and CC (day15) were used to determine LV end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF).

Results

Pooled data yielded moderate-to-strong linear correlations: EDV:

R=0.61; ESV: R=0.72; EF: R=0.81. We analyzed 3 groups, no MI (sham, n=10), small MI (<30% of LV, n=14), and large MI (>30%, n=20).

Volumes and EF were consistently lower by CC than by MRI, but group differences were evident for both techniques. Receiver- operating characteristic (ROC) analysis indicated good sensitivity and specificity for both techniques, with superior results for MRI.

Conclusions

CC and MRI are highly valuable for evaluation of LV volume and function. MRI is recommended for longitudinal studies, accurate absolute volumes, and anatomic information. Unique features of CC are its online signal with high temporal resolution, and advanced analysis of LV function and energetics.

(5)

Introduction

Development and evaluation of new experimental therapies for heart failure increasingly involves functional analyses in mouse models 1. The most widely used model to study the failing heart and evaluate the effects of novel therapies is the myocardial infarction (MI) model. This model is typically created by permanent occlusion of the left anterior descending coronary artery (LAD) 2. Currently, multiple methods are available to assess hemodynamics and ventricular function in the intact mouse. In the present study we compared two methods: magnetic resonance imaging (MRI) and pressure-volume loops by conductance catheter (CC) which both enable cardiac phenotyping under physiological conditions 3,4. Although these techniques are both increasingly used in heart failure studies no direct head-to-head comparison in the (chronic) post-infarct failing mouse heart model is yet available. In addition to comparison of the volumetric parameters which can be obtained by both methods we also illustrate and discuss the complementary additional features of MRI and CC and their value for heart failure research.

Methods Animal model

Experiments were performed in 8- to 10-weeks-old male non-obese diabetic severe combined immunodeficient (NOD/scid) mice (Charles River Laboratories, Maastricht, The Netherlands) with average body weight of 25.3±3.0 g. All procedures were approved by the Animal Research Committee of the Leiden University and conformed to the Guide for Care and Use of Laboratory Animals (NIH publication No.85-23, Revised 1996).

Creation of the myocardial infarction

Myocardial infarctions were created as described previously 5. Briefly, animals were preanesthetized with 5% isoflurane in a gas mixture of oxygen and nitrogen (1:1) and placed supine on a heating pad (37°C). After intubation, ventilation was started (rate 200 breaths/min, stroke volume of 200 μL) using a Harvard Rodent Ventilator (Model 845, Harvard Apparatus, Holliston, MA, USA) with 1.5%

isoflurane. We did not observe evidence of myocardial depression caused by isoflurane anesthetics 6,7. Subsequently, a left thoracotomy was performed in the fifth intercostal space, the pericardial sac was opened, and LAD was ligated permanently using a 7-0 prolene suture. The thorax was closed in layers and the animals were allowed to recover (MI group, n=39). In a control group the same operation was performed without LAD ligation (sham or ‘no MI’ group, n=10). The numbers represent the animals with complete data that survived the entire protocol until sacrifice after the pressure-volume study at day 15. The whole surgical procedure took ~45 minutes, with acute mortality <5%. There was no long- term mortality in the sham group and long-term mortality in the MI group was 25%. A time schedule of the experimental protocol is shown in Figure 1.

(6)

Magnetic resonance imaging

MRI was performed 2 days (infarction size) and 14 days (cardiac function) after surgery. We used a 9.4 T (400 MHz) Bruker BioSpin (Bruker, Etlingen, Germany) system with a 89 mm vertical bore, a shielded gradient set (1 T/m) and a rise time of 110 μs. A birdcage radiofrequency coil (Bruker) with inner diameter of 30 mm was used to transmit and receive the signals. A water-bath around the coil was kept at 29°C to achieve a rectal temperature of ~35°C. Before imaging, mice were anesthetized as described above and placed in a coil with a pneumatic pillow for respiration monitoring and maintained at 1.5 -2% isoflurane guided by respiratory rate. ECG electrodes were attached to the left fore limb and right hind limb. ECG- and respiration-triggered image acquisition was performed using Bruker ParaVision 3.02 software.

On day 2, images were made 40±15 min after injection of the contrast agent Gadolinium-DOTA (Dotarem, Guerbet, Gorinchem, the Netherlands) via the tail vein 8 to determine infarct size. To cover the entire left ventricle (LV), a multi-slice FLASH sequence (18 contiguous, 0.5-mm slices) was used with a 60° flip angle, 45 ms repetition time, 1.9 ms echo time, and 6 averages. On day 14, we performed single-slice cine FLASH imaging using 9 contiguous 1-mm thick slices covering the LV.

Dependent on heart rate (HR), 18-26 frames were acquired per cardiac cycle. The cine FLASH sequences used a 15° flip angle, 7 ms repetition time, 1.9 ms echo time, and the signal was averaged 4 times.

Pixel size was 100 x 100 μm (field of view was 25.6 x 25.6 mm, projected on a 256 x 256 matrix). All images were analyzed with MASS for Mice software 9,10. Epicardial and endocardial borders were delineated manually. Subsequently, LV end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were computed automatically. Gadolinium provided clear contrast between infarcted (white) and non-infarcted myocardium (black) in the delayed enhancement images. Using a grayscale threshold value the enhanced region was automatically detected and the infarcted area calculated (Figure 2). The appropriate threshold value was selected manually based on a histogram of grayscale values from the area between the endocardial and epicardial contours and confirmed by visual inspection of the detected infarct area.

Figure 1: Time schedule of the experimental protocol. MI: myocardial infarction, MRI: magnetic resonance imaging, PV: pressure-volume.

(7)

Left ventricular pressure-volume loops by conductance catheter

On day 15, the animals were again anesthetized as described above. The animals were placed supine on a warming mat under a surgical microscope. Via the right carotid artery, a 1.4 F pressure- conductance catheter (SPR-719, Millar, Houston, TX, USA) was positioned into the LV 11. The catheter used in this study contains four platinum electrodes, each 0.25 mm in width with inter-electrode distances of 0.5, 4.5 and 0.5 mm between electrodes 1-2, 2-3, and 3-4, respectively. A high-fidelity solid state pressure sensor is incorporated between electrodes 2 and 3. A 30 μA, 10 kHz current is applied between electrodes 1 and 4 to generate an intracavitary electric field and the voltage gradient between electrodes 2 and 3 is measured to determine the instantaneous electrical conductance of the blood in the LV (Figure 3). Catheter positioning was guided by online pressure and volume signals:

After passing the aortic valve as indicated by the pressure signal, the catheter was pushed forward to wedge into the LV apex. Subsequently the position was optimized by inspection of the volume signal aiming at a maximal stroke volume. The abdomen was opened to enable preload reductions by compressing the inferior caval vein 12. The CC was connected to a Sigma-SA signal-processor (CD Leycom, Zoetermeer, The Netherlands) for online display and registration of LV pressure and volume signals. Parallel conductance was obtained by the hypertonic saline method using intravenous bolus injections of ~5 μL 13. Slope factor Ơ was obtained using standardized volumetric calibration cuvettes with bore diameters of 3-7 mm as described by Yang et al 14. Data were acquired with Conduct-NT software (CD Leycom) at a sample rate of 2000 Hz and analyzed offline with custom-made software.

Pressure-volume signals were acquired in steady state to obtain HR, cardiac output (CO), EDV, ESV, EF, end-diastolic pressure (EDP), end-systolic pressure (ESP), stroke work (SW), dP/dtMAX and -dP/dtMIN, and isovolumic relaxation time constant Tau. Load-independent indices of systolic and diastolic LV function were determined from pressure-volume relations obtained during preload reductions: the end-systolic pressure-volume relation (ESPVR) and the preload recruitable stroke work relation (PRSWR: SW versus EDV). The slopes of these relations (end-systolic elastance EES and SPRSW, respectively), and their intercepts (ESVESPVR,INT and EDVPRSW,INT) are sensitive measures of intrinsic systolic LV function 15-17. For diastolic function, the chamber stiffness EED was determined from a linear fit to the EDP-volume points.

Figure 2: Assessment of infarct size by delayed enhancement 2 days after myocardial infarction. Epicardial and endocardial contours were manually traced (left panel). Infarct area was then automatically detected using a grayscale threshold value (right panel).

(8)

Statistical analysis

Data were analyzed using SPSS 11.0 software (SPSS Inc, Chicago, IL, USA). To compare MRI and CC- derived indices we performed linear regressions, calculated correlation coefficients, and performed Bland-Altman analyses. Receiver-operating characteristic (ROC) curve analyses were used to determine the optimal cut-off values to discriminate groups and calculate the corresponding sensitivities and specificities. Independent multiple t-tests were performed as post hoc test if one- way ANOVA demonstrated significant differences. Data are reported as mean±SD. A value of p<0.05 was considered to indicate significant differences.

Figure 3: Conductance catheter

(9)

Results

EDV, ESV, and EF as determined by CC and MRI showed moderate-to-strong correlations, although CC-derived values were systemically lower than those by MRI. Orthogonal linear regression results of all pooled data (n=49) are shown in Figure 4. Bland-Altman analyses on the pooled data confirmed the underestimation by the CC showing a bias of -28±29 μL for EDV, -18±27 μL for ESV and -8±8% for EF.

For further analysis, the MI mice were divided into groups with small (<30% of LV) or large (>30%) MI size as determined by the MRI on day 2. Mean infarct sizes in the small MI (n=14) and large MI (n=20) groups were 27±3% and 37±5%, respectively. In 5 mice no MI size could be determined because no successful Gadolinium injection was performed and they were therefore excluded from this part of the analysis (they were, however, included in the analysis of the pooled data as shown in Figure 4).

Figure 5 shows mean EDV, ESV and EF for both methods in all groups. Results indicated that the mean EDV and ESV were almost identical between techniques in the non-infarcted hearts, but that CC- derived volumes were smaller in the MI groups. Interestingly, EF was consistently higher for all groups when measured with MRI (Figure 5).

As shown in Table 1, both methods detected significant differences for all parameters both when comparing sham-operated (no MI) versus small MI and when comparing small MI versus large MI, except that CC-derived EDV did not reach statistical significance (p=0.084) in the latter comparison.

ROC curve analyses determined the optimal cut-off values to discriminate groups and the corresponding sensitivities and specificities. The results indicated that MRI is the best method to distinguish different groups based on measured volumes and EF. For distinction between sham and small MI groups, MRI-derived cut-off values could be chosen with 100% sensitivity and specificity.

Optimal CC-derived cut-offs resulted in a sensitivity of 93% and specificity of 80% for ESV and EF, and in a sensitivity of 73% and specificity of 80% for EDV. For comparison of small versus large MI groups, MRI again demonstrated better results for EDV and ESV, whereas EF showed comparable diagnostic accuracy with both techniques.

To illustrate the effect of MI on LV size and geometry, Figure 6 shows typical examples of short-axis MRI views. Wall thinning indicating the infarct area and enlarged LV leading to reduced EF are clearly visible. Whereas MRI is currently regarded as the gold standard method for visualizing the heart in small animals, the CC has unique features for determining the functional effects of MI. Figure 7 shows the schematic average pressure-volume loops (based on mean EDV, ESV, EDP and ESP) for the three groups. The figure clearly shows the gradual deterioration of LV function evidenced by increased LV volumes, reduced SV (loop width) and SW (loop area), reduced ESP and increased EDP. A more detailed analysis of the functional effects is presented in Table 2. When comparing the small MI versus the sham group, general hemodynamics show a maintained CO but reduced SW. Systolic function is clearly depressed evidenced by a significantly increased ESV, and decreased EF and dP/

dtMAX. Moreover, ESPVR and PRSW show a significant rightward shift as illustrated by the increase of their intercepts, indicating a significant decrease in systolic myocardial function. EDV and EDP are both increased, whereas -dP/dtMIN was significantly reduced. At this stage, however, Tau and diastolic stiffness (EED) were not yet altered, indicating that intrinsic diastolic function was largely maintained and that the increases in EDP and EDV mainly represent changes in loading, which enable the LV to maintain CO by using its Starling mechanism. The functional decline is much more profound in the large MI group: General hemodynamics are significantly depressed as indicated by a further 40%

decline in CO and almost 50% decrease in SW. The systolic indices indicate a further significant decrease in LV function and, at this stage, diastolic LV function is also impaired (although Tau only reached marginal significance). The 88% increase in diastolic stiffness clearly hampered the LV to further employ the Starling mechanism to compensate for the loss in systolic function.

(10)
(11)

Figure 6: Example of magnetic resonance images obtained at day 14. Short axis view of a sham-operated heart (no myocardial infarction, MI), a heart with small MI and a heart with large MI. Note the wall thinning in the anterior left ventricular (LV) wall (small MI) or the entire LV wall (large MI), indicating the infarct area. EDV: end-diastolic volume, ESV: end-systolic volume.

Sham Small MI Large MI

EDV

ESV

Figure 5: Mean end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) by magnetic resonance imaging (MRI) and conductance catheter (CC) in mice without myocardial infarction (MI; sham), small (<30%) and large (>30%) MI. MRI data were obtained 14 days after MI, CC data 15 days after MI. Significances between groups: * p<0.01, ** p<0.001. Significances between methods: # p<0.05, ## p<0.001. Detailed statistics are presented in Table 1.

(12)

Figure 7: Schematic pressure-volume loops (based on mean end-diastolic and end-systolic pressures and volumes) obtained by conductance catheter in sham-operated mice without myocardial infarction (MI), and mice with small and large MI. LV: left ventricular.

Groups Sham vs. Small MI Small MI vs. Large MI

ROC analysis ROC analysis

Sham Small MI Large MI P Cut-off Sens Spec AUC P Cut-off Sens Spec AUC MRI

EDV (μL) 51±5 97±22 127±26 <0.001 61 100% 100% 1.00 0.002 102 95% 93% 0.86

ESV (μL) 25±4 71±24 104±29 <0.001 36 100% 100% 1.00 <0.001 77 95% 93% 0.87

EF (%) 52±4 28±8 19±7 <0.001 42 100% 100% 1.00 0.001 25 85% 80% 0.86

CC

EDV (μL) 50±16 75±17# 87±20## 0.002 63 73% 80% 0.85 0.084 81 50% 67% 0.61

ESV (μL) 32±11 58±16# 76±21## 0.001 41 93% 80% 0.93 0.009 58 75% 60% 0.73

EF (%) 36±9## 24±7# 13±6## <0.001 31 93% 80% 0.83 <0.001 20 85% 87% 0.90

Table 1: Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) by magnetic resonance imaging (MRI) and conductance catheter (CC) in mice without myocardial infarction (MI; Sham), with small MI (<30% of LV), or large MI (>30%) at day 14 (MRI) or day 15 (CC). Receiver-operating characteristic (ROC) analysis to determine optimal cut-off, sensitivity (Sens), specificity (Spec) and area under the curve (AUC). Significant differences between corresponding values obtained by MRI and CC within the same group: # p<0.05, ## p<0.001.

(13)

Groups P-values

Sham Small MI Large MI Sham vs. Small MI Small vs. Large MI

General

HR (beats/min) 424±50 438±45 452±62 0.498 0.476

CO (mL/min) 8.6±3.3 7.9±2.9 4.7±1.9# 0.620 <0.001

SW (mmHg.mL) 1.76±0.69 1.07±4.9* 0.55±0.30# 0.009 0.001

EA (mmHg/μL) 5.5±4.2 4.8±1.4 8.2±2.9# 0.572 <0.001

EES / EA 0.58±0.32 0.56±0.28 0.30±0.11# 0.860 0.004

Systolic

ESV (μL) 32±11 58±16* 76±21# 0.001 0.009

ESP (mmHg) 89±20 81±16 77±14 0.303 0.398

EF (%) 36±9 24±7* 13±6# <0.001 <0.001

dP/dtMAX (mmHg/ms) 8.2±1.8 6.2±2.5* 4.6±1.7# 0.036 0.033

EES (mmHg/μL) 3.0±2.0 2.5±1.2 2.3±0.7 0.461 0.648

ESVESPVR,INT (μL) 29±9 52±19* 74±20# 0.001 0.008

S-PRSW (mmHg) 57±21 53±12 36±19# 0.557 0.016

EDVPRSW,INT (μL) 35±7 71±19* 95±23# <0.001 0.009

Diastolic

EDV (μL) 50±16 75±17* 87±20 0.002 0.084

EDP (mmHg) 6.6±3.1 12.4±7.3* 14.8±6.6 0.025 0.329

-dP/dtMIN (mmHg/ms) 5.8±1.2 4.1±1.2* 3.3±1.3 0.003 0.117

Tau (ms) 14.8±4.0 16.5±5.4 20.8±7.5 0.409 0.085

EED (mmHg/μL) 0.61±0.58 0.59±0.32 1.11±0.81# 0.936 0.048

Table 2: Conductance catheter-derived functional indices for sham-operated (no MI), small MI and large MI mice at day 15.

MI: myocardial infarction, HR: heart rate, CO: cardiac output, SW: stroke work, EA: effective arterial elastance, EES: end-systolic ventricular elastance, ESV: end-systolic volume, ESP: end-systolic pressure, EF: ejection fraction, dP/dtMAX: maximal rate of LV pressure increase, ESVESPVR,INT: intercept of the ESPVR (end-systolic pressure-volume relation) at ESP=81 mmHg (overall mean), S-PRSW: slope of preload recruitable stroke work relation (PRSW), EDVPRSW,INT: intercept of the PRSW at EDV=74 μL (overall mean), EDV: end-diastolic volume, EDP: end-diastolic pressure, -dP/dtMIN: maximal rate of LV pressure decline, Tau: relaxation time constant, EED: end-diastolic stiffness. * indicates significance of small MI group versus sham group; # indicates significance of large MI group versus small MI group.

(14)

Discussion

The rationale for our critical evaluation of functional measurements in the murine MI model is found in the extensive application of this model in current cardiovascular research 1. Both MRI and CC are widely used to assess LV function in such studies, but no direct comparative analysis is yet available for the post-infarct failing mouse heart. We demonstrated for the first time in a mouse model with vast LV remodeling that LV volumetric indices obtained by MRI and CC are strongly correlated and that both methods reliably detect changes in LV volumes and EF. In addition, the two techniques yield highly complementary information. A previous study 18 in the normal mouse heart also indicated a strong linear correlation between MRI- and CC-derived volumes. In addition, in line with our findings, these authors showed that CC-derived volumes underestimated MRI-derived volumes. However, in our study this underestimation was not present in the sham (no MI) animals, but only in the infarct groups with a larger EDV. An earlier study 19 demonstrated an even more pronounced underestimation which could be partly due to a larger baseline MRI-derived EDV (79±8 versus 51±5 μL in our study) consistent with a higher body weight (29±4 versus 25±3 g). However, differences could also be related to the methods used for CC calibration 18,20. Unfortunately, this study only presented mean values and the correlation between MRI-derived and CC-derived volumes was not investigated. The authors repeated their measurements in mice with LV hypertrophy induced by aortic constriction.

Compared with control, the hypertrophic animals showed increased LV volumes with both methods;

however, with MRI the increase was largest in EDV and with CC the increase was mainly in ESV. This resulted in an observed increase in stroke volume with MRI and a tendency for a decrease with CC, whereas EF was unchanged with MRI and decreased with CC. Based on these findings the authors concluded that directional changes induced by aortic constriction obtained by CC are inaccurate.

Obviously, this conclusion can only be drawn based on the assumption that MRI represented the gold standard. Although this is generally assumed, the reliability of MRI to assess LV volumes in the hypertrophic mouse model has not been directly demonstrated and was based mainly on accuracy of LV mass estimates versus autopsy data. In fact, from a physiological standpoint the CC-derived decrease in CO and EF may be more plausible than the opposite changes found with MRI: previous (echocardiographic) studies in similar models typically showed reduced SV or CO, unchanged LV end-diastolic diameters and reduced fractional shortening in line with the CC-derived findings 21-24. Thus, further studies may be needed to assess the reliability of both MRI and CC in the (non-failing) hypertrophic mouse model.

It should be noted that in all previous comparative studies, including ours, CC- and MRI-derived volumes were not obtained simultaneously, and that conditions in the two measurement sessions were generally partly different. In all cases, CC measurements were obtained after the MRI assessments which, particularly in failing heart models, may have resulted in more depressed LV function in the later session after repeated anesthesia. In our study both sessions were performed in closed-chest conditions. The abdomen was opened during the CC measurements for performing caval occlusions, however, this would not be expected to have important hemodynamic consequences since intra-thoracic pressure was not disturbed. However, Nielsen et al 18 introduced the CC via the apex after thoracotomy. The effects of opening the chest may be difficult to predict and is dependent on anesthesia, potential blood loss and fluid supplementation. In general, lower pressures and absolute volumes could be expected but reductions in SV and CO may be limited due to simultaneous reduction in afterload 25. In addition, MRI was generally performed during spontaneous breathing, whereas CC measurements were done after intubation and with artificial ventilation. These different protocols may have resulted in different levels of anesthesia as suggested by HR differences. Most studies report higher HR during CC sessions 18,19. Moreover, the CC measurements were generally

(15)

during sequential MRI and CC sessions, the finding of relative underestimation by CC appears to be fairly consistent, particularly for larger LV volumes.

Several factors may have contributed. With regard to the CC method, LV volume is measured in one single segment defined by the distance between the sensing electrodes (4.5 mm) which, particularly in an extremely dilated LV, may largely explain the observed underestimation. Furthermore,

issues related to calibration of the CC may have played a role. In our study the slope factor Ơ was determined in vitro by placing the CC in different sized cylinders with diameters ranging from 3 to 7 mm. The calibration curve was highly linear with a slope Ơ = 0.29±0.02 and correlation r2 = 0.986, but theoretically the relation between true volume and conductance becomes non-linear if the diameter is large compared to the distance between the current electrodes (5.5 mm). This would be the case for extremely dilated LVs in the present study, and result in underestimation. Furthermore, parallel conductance (mean value 31±5 μL) was assessed by intravenous hypertonic saline injections whereas, ideally, pulmonary artery injections should be used. Consistent with earlier studies in sheep

13, a recent study in mice 18 showed a tight correlation between parallel conductances obtained from pulmonary artery and intravenous injections, but the latter consistently produced slightly higher values. As parallel conductance is subtracted from the raw measured conductance, this could also have contributed to the underestimation of volumes by CC compared to MRI.

MRI is considered the gold standard for absolute LV volume measurements as it does not require geometric assumptions, and excellent agreement with autopsy data was demonstrated 18,19,28,29. Some limitations, however, should be mentioned. Agreement with autopsy data was obtained for LV wall mass and to infer accuracy of LV cavity volumes may not be fully justified. The temporal resolution of MRI in the present study was 7 ms which at a typical cardiac cycle length of 150 ms corresponds to 21 frames/beat. Considering that the relaxation time constant was in the range of 15-20 ms (Table 2), at least two subsequent frames are obtained in the isovolumic relaxation period and thus the temporal resolution should be sufficient to accurately determine minimal LV volume (ESV). The situation at end-diastole is more critical because the isovolumic contraction period generally is shorter than the isovolumic relaxation period 30. Moreover, in case of mitral insufficiency, which presumably was present in some of the dilated hearts, substantial decreases in LV volume may occur before aortic valve opening, resulting in a very short isovolumic period. Thus, the limited temporal resolution of MRI could result in underestimation of true maximal volume. LV volume was calculated by summation of multiple slices and thus the spatial resolution of MRI was partly determined by slice thickness which was set at 1 mm in our study. To avoid discontinuous phasic volume signals we included only slices that showed the LV cavity throughout the cardiac cycle. This could have resulted in underestimation of EDV, because in practice the number of included slices was determined by ESV.

Another limitation is related to the fact that MRI images are reconstructions based on data acquired over a large number of cardiac cycles. Particularly in the failing heart, rhythm disturbances and respiratory variability could result in gating problems and, subsequently, relatively long acquisition times which combined with inherent hemodynamic instability might affect image quality and reduce the accuracy and reproducibility of the data. Despite these (theoretical) limitations, image quality was adequate to reliably trace the endocardial borders in all animals.

The significant correlation between MRI- and CC-derived volumes and EFs indicated that both methods can be used to detect changes in LV volume. However, as the absolute values of the volumetric indices were not the same, the methods are not interchangeable. This conclusion is not surprising and in line with clinical studies comparing imaging modalities 31. Bland-Altman analyses confirmed the underestimation by the CC method and showed that underestimation was more pronounced at higher volumes but that variability remained fairly constant; however, as the volumetric values obtained by the two methods were not expected to be interchangeable we feel

(16)

that comparison by linear regression analysis is more insightful. To quantify the diagnostic accuracy of MRI and CC we determined sensitivity and specificity of the volumetric indices. The results were good for both methods, but MRI was clearly superior. It should be noted that this analysis implicitly assumes a strong correlation between infarct sizes and subsequent cardiac enlargement 32,33. The smallest infarct size in our study was 21%, which according to previous studies causes a drop in EF of at least 15-20% 32 and thus no overlap in real volumes between the group without MI and the small MI group would be expected. However, the small MI and large MI groups were created retrospectively with small MI ranging from 21% to 30% and the large MI ranging from 31% to 47%. Thus some overlap of absolute volumes between groups and therefore no 100% sensitivity and specificity should be expected. Despite this, the ROC analyses indicated excellent results for MRI and good results for CC, particularly for CC-derived EF with 85% sensitivity and 87% specificity.

Finally, MRI and CC each have distinct advantages and disadvantages that should be considered.

The non-invasive character of MRI is an important advantage which enables longitudinal studies in individual animals under physiological conditions 34,35. In particular, serial MRI studies are highly valuable to investigate the time course of ventricular remodeling after MI 36,37. The use of contrast agents such as Gadolinium in conjunction for cardiac MRI provides for the accurate assessment of infarct size early after MI 8,32,33. In addition, advanced techniques of cardiac MRI such as myocardial tagging can be used to assess regional contractile function in the mouse heart over time after MI 38. Regional measurements may also be used to determine infarct size by considering the myocardial portion with significant thinning and akinesia or dyskinesia during systole 37,39. Moreover, magnetic resonance may also be used for spectroscopy (MRS) to study metabolism and energetics of the heart

40. As a disadvantage, MRI studies are time-consuming both for data acquisition and for data analysis.

Moreover, the equipment is expensive, requires considerable infrastructure and highly trained personnel. As a consequence, availability is generally limited.

The CC method, on the other hand, not only provides an instantaneous volume signal but by combining this with instantaneous LV pressure, pressure-volume relations can be obtained which are generally regarded as the gold standard for assessing LV systolic and diastolic function because these relations yield highly sensitive, load-independent indices. In the present study this was illustrated in Table 2 which shows, for example, that although when going from sham (no MI) to small MI to large MI the volumetric changes are largest at the first step, the functional effects particularly regarding intrinsic diastolic function and cardiac output are much more pronounced in the second step. Moreover, CC measurements give insight in the underlying mechanisms by providing detailed information on the extent of systolic and diastolic dysfunction and have possibilities for advanced analysis of mechanics and energetics of the heart and its interaction with the vascular system 41,42. In addition, the temporal resolution of the pressure-volume signals is high (0.5 ms in our study) and its continuous, online (beat-to-beat) nature enables dynamic studies which are not feasible with imaging techniques which require steady states. As a disadvantage, the CC is highly invasive and is generally only performed as a terminal study, although recently the feasibility of repeated measurements in conscious mice has been demonstrated 43.

In conclusion, our study indicates that CC and MRI are both methods that are highly valuable for evaluation of LV volume and function in murine MI studies. Selection of the optimal method depends on the specific research question: MRI is recommended for longitudinal studies, for accurate absolute volumetric measurements, and when anatomical information is essential. The unique features of the CC method are its online signal with high temporal resolution, and the possibilities for advanced

(17)

Reference List

1.

Doevendans PA, Daemen MJ, de Muinck ED, Smits JF. Cardiovascular phenotyping in mice. Cardiovasc Res.

1998; 39:34-49.

2.

Tarnavski O, McMullen JR, Schinke M, Nie Q, Kong S, Izumo S. Mouse cardiac surgery: comprehensive techniques for the generation of mouse models of human diseases and their application for genomic studies. Physiol Genomics.

2004; 16:349-360.

3.

Costandi PN, McCulloch AD, Omens JH, Frank LR. High-resolution longitudinal MRI of the transition to heart failure.

Magn Reson Med. 2007; 57:714-720.

4.

Walther T, Steendijk P, Westermann D, Hohmann C, Schulze K, Heringer- Walther S, Schultheiss HP, Tschope C. Angiotensin deficiency in mice leads to dilated cardiomyopathy. Eur J Pharmacol. 2004; 493:161-165.

5.

Winter EM, Grauss RW, Hogers B, van Tuyn J, van der Geest RJ, Lie-Venema H, Vicente Steijn R, Maas S, DeRuiter MC, deVries AAF, Steendijk P, Doevendans PA, van der Laarse A, Poelmann RE, Schalij MJ, Atsma DE, Gittenberger- de Groot AC. Preservation of left ventricular function and attenuation of remodeling after transplantation of human epicardium-derived cells into the infarcted mouse heart. Circulation.

2007; 116:917-927.

6.

Janssen BJ, De Celle T, Debets JJ, Brouns AE, Callahan MF, Smith TL. Effects of anesthetics on systemic hemodynamics in mice. Am J Physiol Heart Circ Physiol.

2004; 287:H1618-H1624.

7.

Matsuda Y, Ohsaka K, Yamamoto H, Natsume K, Hirabayashi S, Kounoike M, Inoue M. Comparison of newly developed inhalation anesthesia system and intraperitoneal anesthesia on the hemodynamic state in mice. Biol Pharm Bull. 2007; 30:1716-1720.

8.

Yang Z, Berr SS, Gilson WD, Toufektsian MC, French BA. Simultaneous evaluation of infarct size and cardiac function in intact mice by contrast-enhanced cardiac

9.

van der Geest RJ, Buller VG, Jansen E, Lamb HJ, Baur LH, van der Wall EE, de Roos A, Reiber JH. Comparison between manual and semiautomated analysis of left ventricular volume parameters from short-axis MR images. J Comput Assist Tomogr. 1997; 21:756-765.

10.

van der Geest RJ, Reiber JH.

Quantification in cardiac MRI. J Magn Reson Imaging. 1999; 10:602-608.

11.

Georgakopoulos D, Mitzner WA, Chen CH, Byrne BJ, Millar HD, Hare JM, Kass DA. In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry. Am J Physiol. 1998;

274:H1416-H1422.

12.

Bal MP, de Vries WB, van der Leij FR, van Oosterhout MF, Berger RM, Baan J, van der Wall EE, van BF, Steendijk P.

Neonatal glucocorticosteroid treatment causes systolic dysfunction and compensatory dilation in early life:

studies in 4-week-old prepubertal rats.

Pediatr Res. 2005; 58:46-52.

13.

Steendijk P, Baan J. Comparison of intravenous and pulmonary artery injections of hypertonic saline for the assessment of conductance catheter parallel conductance. Cardiovasc Res.

2000; 46:82-89.

14.

Yang B, Larson DF, Beischel J, Kelly R, Shi J, Watson RR. Validation of conductance catheter system for quantification of murine pressure-volume loops. J Invest Surg. 2001; 14:341-355.

15.

Burkhoff D, Mirsky I, Suga H.

Assessment of systolic and diastolic ventricular properties via pressure- volume analysis: a guide for clinical, translational, and basic researchers.

Am J Physiol Heart Circ Physiol. 2005;

289:H501-H512.

16.

Glower DD, Spratt JA, Snow ND, Kabas JS, Davis JW, Olsen CO, Tyson GS, Sabiston DC, Jr., Rankin JS. Linearity of the Frank-Starling relationship in the intact heart: the concept of preload recruitable stroke work. Circulation.

17.

Steendijk P, Baan J, Jr., van der Velde ET, Baan J. Effects of critical coronary stenosis on global systolic left ventricular function quantified by pressure-volume relations during dobutamine stress in the canine heart. J Am Coll Cardiol. 1998; 32:816-826.

18.

Nielsen JM, Kristiansen SB, Ringgaard S, Nielsen TT, Flyvbjerg A, Redington AN, Botker HE. Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration. Am J Physiol Heart Circ Physiol. 2007; 293:H534-H540.

19.

Jacoby C, Molojavyi A, Flogel U, Merx MW, Ding Z, Schrader J.

Direct comparison of magnetic resonance imaging and conductance microcatheter in the evaluation of left ventricular function in mice. Basic Res Cardiol. 2006; 101:87-95.

20.

Nielsen JM, Redington AN, Kristiansen SB. Commentary on “Direct comparison of magnetic resonance imaging and conductance microcatheter in the evaluation of left ventricular function in mice” by Jacoby et al. in Basic Res Cardiol 101:87-95 (2006). Basic Res Cardiol. 2006; 101:96-97.

21.

Brickson S, Fitzsimons DP, Pereira L, Hacker T, Valdivia H, Moss RL. In vivo left ventricular functional capacity is compromised in cMyBP-C null mice.

Am J Physiol Heart Circ Physiol. 2007;

292:H1747-H1754.

22.

Grieve DJ, Byrne JA, Siva A, Layland J, Johar S, Cave AC, Shah AM. Involvement of the nicotinamide adenosine dinucleotide phosphate oxidase isoform Nox2 in cardiac contractile dysfunction occurring in response to pressure overload. J Am Coll Cardiol. 2006;

47:817-826.

23.

Matsusaka H, Ide T, Matsushima S, Ikeuchi M, Kubota T, Sunagawa K, Kinugawa S, Tsutsui H. Targeted deletion of matrix metalloproteinase 2 ameliorates myocardial remodeling in mice with chronic pressure overload.

Hypertension. 2006; 47:711-717.

(18)

Doppler tissue imaging in mice. J Am Soc Echocardiogr. 2003; 16:1144-1149.

25.

Lips DJ, van der Nagel T, Steendijk P, Palmen M, Janssen BJ, van Dantzig JM, de Windt LJ, Doevendans PA.

Left ventricular pressure-volume measurements in mice: comparison of closed-chest versus open-chest approach. Basic Res Cardiol. 2004;

99:351-359.

26.

Schneider JE, Hulbert KJ, Lygate CA, Ten Hove M, Cassidy PJ, Clarke K, Neubauer S. Long-term stability of cardiac function in normal and chronically failing mouse hearts in a vertical-bore MR system. MAGMA. 2004; 17:162-169.

27.

Wiesmann F, Neubauer S, Haase A, Hein L. Can we use vertical bore magnetic resonance scanners for murine cardiovascular phenotype characterization? Influence of upright body position on left ventricular hemodynamics in mice. J Cardiovasc Magn Reson. 2001; 3:311-315.

28.

Siri FM, Jelicks LA, Leinwand LA, Gardin JM. Gated magnetic resonance imaging of normal and hypertrophied murine hearts. Am J Physiol. 1997;

272:H2394-H2402.

29.

Ruff J, Wiesmann F, Hiller KH, Voll S, von KM, Bauer WR, Rommel E, Neubauer S, Haase A. Magnetic resonance microimaging for noninvasive quantification of myocardial function and mass in the mouse. Magn Reson Med. 1998; 40:43-48.

30.

Zhang Y, Takagawa J, Sievers RE, Khan MF, Viswanathan MN, Springer ML, Foster E, Yeghiazarians Y. Validation of the wall motion score and myocardial performance indexes as novel techniques to assess cardiac function in mice after myocardial infarction.

Am J Physiol Heart Circ Physiol. 2007;

292:H1187-H1192.

31.

Bellenger NG, Burgess MI, Ray SG, Lahiri

they interchangeable? Eur Heart J. 2000;

21:1387-1396.

32.

Takagawa J, Zhang Y, Wong ML, Sievers RE, Kapasi NK, Wang Y, Yeghiazarians Y, Lee RJ, Grossman W, Springer ML.

Myocardial infarct size measurement in the mouse chronic infarction model:

comparison of area- and length-based approaches. J Appl Physiol. 2007;

102:2104-2111.

33.

Watzinger N, Lund GK, Higgins CB, Wendland MF, Weinmann HJ, Saeed M. The potential of contrast-enhanced magnetic resonance imaging for predicting left ventricular remodeling. J Magn Reson Imaging. 2002; 16:633-640.

34.

Arai T, Kofidis T, Bulte JW, de Bruin J, Venook RD, Berry GJ, Mcconnell MV, Quertermous T, Robbins RC, Yang PC. Dual in vivo magnetic resonance evaluation of magnetically labeled mouse embryonic stem cells and cardiac function at 1.5 t. Magn Reson Med. 2006; 55:203-209.

35.

Ross AJ, Yang Z, Berr SS, Gilson WD, Petersen WC, Oshinski JN, French BA. Serial MRI evaluation of cardiac structure and function in mice after reperfused myocardial infarction. Magn Reson Med. 2002; 47:1158-1168.

36.

Nahrendorf M, Hiller KH, Hu K, Ertl G, Haase A, Bauer WR. Cardiac magnetic resonance imaging in small animal models of human heart failure. Med Image Anal. 2003; 7:369-375.

37.

Nahrendorf M, Wiesmann F, Hiller KH, Hu K, Waller C, Ruff J, Lanz TE, Neubauer S, Haase A, Ertl G, Bauer WR. Serial cine- magnetic resonance imaging of left ventricular remodeling after myocardial infarction in rats. J Magn Reson Imaging. 2001; 14:547-555.

38.

Epstein FH, Yang Z, Gilson WD, Berr SS, Kramer CM, French BA. MR tagging early after myocardial infarction in mice demonstrates contractile dysfunction

Ertl G, Bauer WR. In vivo assessment of cardiac remodeling after myocardial infarction in rats by cine-magnetic resonance imaging. J Cardiovasc Magn Reson. 2000; 2:171-180.

40.

Neubauer S. The failing heart--an engine out of fuel. N Engl J Med. 2007;

356:1140-1151.

41.

Murphy AM, Kogler H, Georgakopoulos D, McDonough JL, Kass DA, Van Eyk JE, Marban E. Transgenic mouse model of stunned myocardium. Science. 2000;

287:488-491.

42.

Segers P, Georgakopoulos D, Afanasyeva M, Champion HC, Judge DP, Millar HD, Verdonck P, Kass DA, Stergiopulos N, Westerhof N. Conductance catheter- based assessment of arterial input impedance, arterial function, and ventricular-vascular interaction in mice.

Am J Physiol Heart Circ Physiol. 2005;

288:H1157-H1164.

43.

Joho S, Ishizaka S, Sievers R, Foster E, Simpson PC, Grossman W.

Left ventricular pressure-volume relationship in conscious mice. Am J Physiol Heart Circ Physiol. 2007;

292:H369-H377.

(19)

Referenties

GERELATEERDE DOCUMENTEN

This is a rich source of various immature cells that are applied in basic and clinical experimental cardiac regeneration therapy, being hematopoietic stem cells (HSCs) 38,48-50 ,

License: Licence agreement concerning inclusion of doctoral thesis in the Institutional Repository of the University of Leiden. Downloaded

OT: outflow tract, SV: sinus venosus, PEO: proepicardial organ, AVC: atrioventricular cushion, EPDC: epicardium-derived cell, Ep: epicardium, V: ventricle, A: atrium,

It seems unlikely that new cardiomyocyte formation 40 contributed to the increment in wall thickness in the hEPDC group, because the cardiomyocytes observed in the

Therefore, we investigated by lentiviral fluorescent (Katushka 27 ) labeling of the host epicardium whether new EPDCs were regenerated after MI. We first demonstrated by in

Trombospondin-1 (TSP-1) mRNA expression in the Mix-culture significantly increased after 7 days of hypoxia compared to the average of single CMPC and EPDC culture (Figure 4a;

License: Licence agreement concerning inclusion of doctoral thesis in the Institutional Repository of the University of Leiden. Downloaded

Key findings of the present study are that in an immune-compromised mouse model of acute MI, intramyocardial injection of hMSCs from patients with IHD resulted in i) a