• No results found

The sense or nonsense of mobile-bearing total knee prostheses Wolterbeek, N.

N/A
N/A
Protected

Academic year: 2021

Share "The sense or nonsense of mobile-bearing total knee prostheses Wolterbeek, N."

Copied!
2
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

The sense or nonsense of mobile-bearing total knee prostheses

Wolterbeek, N.

Citation

Wolterbeek, N. (2011, November 10). The sense or nonsense of mobile-bearing total knee prostheses. Retrieved from https://hdl.handle.net/1887/18058

Version: Corrected Publisher’s Version

License: Licence agreement concerning inclusion of doctoral thesis in the Institutional Repository of the University of Leiden Downloaded

from: https://hdl.handle.net/1887/18058

Note: To cite this publication please use the final published version (if applicable).

(2)

The sense or nonsense of

mobile-bearing total knee prostheses

Nienke Wolterbeek

The sense or nonsense of mobile -b earing t otal k nee pr ostheses N ienk e W olt er beek

UITNODIGING

Op donderdag 10 november 2011 om 13.45 uur zal ik mijn proefschrift

‘The sense or nonsense of mobile-bearing total knee prostheses’

in het openbaar verdedigen in het Groot Auditorium

Lekenpraatje om 12:45 uur in het Klein Auditorium

Rapenburg 67-73, Leiden

Nienke Wolterbeek

Van der Pekstraat 126 1031 EJ Amsterdam nienkew66@hotmail.com

Paranimfen:

Onno Manck (06-23760668) Caroline Doorenbosch (cdoorenbosch@xs4all.nl)

Referenties

GERELATEERDE DOCUMENTEN

The aim of this study was to evaluate early migration of the tibial component and kinematics of a mobile-bearing and fixed-bearing total knee prosthesis of the same

Despite the lower congruency, the Triathlon MB group showed equal motion of the insert and femoral component during the whole range of flexion, without occurrence of reversed

Despite the mobile insert was following the femoral component during motion, and therefore performed as intended, no kinematic advantages of the mobile-bearing total knee

Mobile bearing vs fixed bearing prostheses for total knee arthroplasty for post-operative functional status in patients with osteoarthritis and rheumatoid arthritis.. Rotating

However, high congruency of the insert seems to lead to undesired restrictions of motions of the femoral component which in turn might be a disadvantage for the functioning

Op dit moment is er geen overtuigende reden voor het wereldwijd gebruik van de totale knieprothese met een beweegbaar lager ten opzichte van de succesvolle totale knieprothese met

Her Master’s project at the Motion Lab of the VU Medical Center was a joint effort between the Department of Orthopaedics of the Leiden University Medical Center and the Department

At the current time there is no compelling reason for the widespread use of mobile-bearing total knee prostheses over successful fixed- bearing total knee prostheses either in terms