University of Groningen

Positron emission tomography for quality assurance in proton therapy

Buitenhuis, Tom

DOI:

10.33612/diss.110452833

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date: 2020

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

Buitenhuis, T. (2020). Positron emission tomography for quality assurance in proton therapy. Rijksuniversiteit Groningen. https://doi.org/10.33612/diss.110452833

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

Stellingen behorend bij het proefschrift

Positron Emission Tomography for

Quality Assurance in Proton Therapy

1. Using 12N PET imaging, accurate feedback on the dose delivery can be obtained in real-time.

2. Good quality PET data can be obtained during beam delivery by removing prompt counts using an anti-coincidence filter with the delivered proton bunches.

3. A large dual panel PET scanner that images a single spot at the beginning of the dose delivery, can measure a 5 mm range shift with millimeter accuracy using 12N imaging.

4. Optimization of in vivo dose delivery verification requires detailed investigations of a variety of clinical cases; irradiation of simple phantoms does not capture the full complexity of the problem.

5. An advantage of PET over prompt gamma ray imaging is the fact that the basic technology is not developed solely for range verification.

6. The need for accurate range verification is increased by developments in hadron therapy such as hypofractionation or the use of high instantaneous beam intensities.

7. Fast PET measurements of the in-vivo proton range will provide comfort in the delivery of more bold treatment plans with reduced margins, which will result in clinical benefits. 8. Technological artifacts can mean different things to different

people and are shaped by relevant social groups.

(Pinch and Bijker, 1984)

Tom Buitenhuis 10 januari 2020

Referenties

GERELATEERDE DOCUMENTEN

For IMPT, the planning target volume (PTV) concept of photon therapy can be replaced by a clinical target volume (CTV) robust optimisation technique, which incorporates setup

The voxel-wise worst-case dose distributions obtained from the 4DREM were used to assess the robustness of 3D and 4D robust optimised IMPT treatment plans of a lung and

Figure 1: Illustration of delivered dose as a function of penetration depth inside the body, comparing photon and proton beams.. The dose of several proton beams are added to form

The purpose of this thesis research is to determine the presence of Osteochondritis Dissecans in a skeletal sample from the mid-19th century from the Middenbeemster cemetery in

SAELA has also published quality papers in reputable conference volumes and accredited scholarly journals (which have, on occasions, made available space for

i) Two coincidence measurements were done, with the 22 Na source placed in the midpoint on the aluminum housing of detector 1 in the first measurement, and in.. the second

These images have been compared using the γ-index, Structural Similarity Index (SSIM) and Pearson Correlation Coeffi- cient (PCC) to determine an optimal protocol for proton

When imaging in other regions and/or the patient makes panel placement more difficult, different in-beam geometries or even a full ring scanner with an in-room protocol should