Cover Page

The handle http://hdl.handle.net/1887/38444 holds various files of this Leiden University dissertation

Author: Haan, Arthur den

Title: Nuclear magnetic resonance force microscopy at millikelvin temperatures

Issue Date: 2016-03-09

(2)

Hier komt de tekst voor de rug; hoe dikker de rug, hoe groter de tekst

Nuclear magnetic resonance force microscopy

at millikelvin temperatures

Arthur den Haan

Casimir PhD series 2015-37 ISBN 978-90-8593-243-7

Nuclear magnetic resonance force microscopy at millikelvin temperatures Arthur den Haan 2016

Invitation

to the defense of the PhD thesis by Arthur den Haan When?

Wednesday,

the 9

th

of March 2016, at 15:00h

Jelmer Wagenaar jelmerjt@gmail.com

Daan van der Velde daanvdvelde@gmail.com

Where?

Academy building Rapenburg 73, Leiden

Arthur den Haan 06-33101901

arthur.denhaan@gmail.com

Paranimfen

Referenties

GERELATEERDE DOCUMENTEN

 Treat to Target recommendation 5: ‘Measures of disease activity must be obtained and documented regularly as frequently as monthly for patients with high/moderate disease

8 Radio frequency pulses for nuclear magnetic resonance force mi- croscopy 71 8.1 The motion of a magnetic moment in an external magnetic

Magnetic resonance force microscopy (MRFM) has been introduced as a possible tool to obtain nanometer 3D resolution or even the 3D atomic structure of biological samples and

Hz... Detector noise When measuring the movement of the cantilever, noise will be introduced by the sensor detecting the motion, which can be a combination of several noise sources.

We investigate the degradation of the magnetic moment of a 300 nm thick FePt film induced by Focused Ion Beam (FIB) milling.. A 1 µm×8 µm rod is milled out of a film by a FIB

Even though PT refrigerator systems become more available, most of the low temperature vibration sensitive measurements like low temperature atomic force mi- croscopy (AFM) and

The coupling of the tip with the magnetic field manifests itself as a shift in the resonance frequency of the cantilever and as addi- tional dissipation which reduces its quality

We positioned the cantilever above the copper, sufficiently close to the pick-up coil for a good coupling and close to the RF wire (as indicated by a small black dot in figure