• No results found

University of Groningen Microfluidic tools for multidimensional liquid chromatography Ianovska, Margaryta

N/A
N/A
Protected

Academic year: 2021

Share "University of Groningen Microfluidic tools for multidimensional liquid chromatography Ianovska, Margaryta"

Copied!
2
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

University of Groningen

Microfluidic tools for multidimensional liquid chromatography

Ianovska, Margaryta

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from

it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date:

2018

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

Ianovska, M. (2018). Microfluidic tools for multidimensional liquid chromatography. University of Groningen.

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

List of publications

200

List of publications:

Published:

Ianovska M.A., Mulder P.P.M.F.A., Verpoorte E. Development of small-volume, microfluidic

chaotic mixers for future application in two-dimensional liquid chromatography, RSC Adv., 2017,

7, 9090.

Submitted:

De Haan P., Ianovska M.A., Mathwig K., van Lieshout G., Triantis V., Bouwmeester H., Verpoorte

E. Digestion-on-a-Chip: A Continuous-Flow Modular Microsystem for Enzymatic Digestion for

Gut-on-a-Chip Applications, Lab on a Chip.

In preparation:

Ianovska M.A., Heiskanen A., Wouters B., Ritzen E., Mengerink Y., Schoenmakers P., Emnéus J.,

Verpoorte E. Microfluidic micromixer as a tool to overcome solvent incompetibilities in

two-dimensional liquid chromatography.

Ianovska M.A., Mulder P.P.M.F.A., Verpoorte E.

Novel micromixers based on chaotic advection

and their application —a review.

Ianovska M.A., Mulder J.-P.S.H., Verpoorte E. Fabrication of a pressure-resistant microfluidic

mixer in fused silica using Selective Laser-Induced Etching.

Referenties

GERELATEERDE DOCUMENTEN

Mogelijk wordt de lagere luchtvochtigheid bij bedrijf D verklaard door geringe verdamping vanuit de bodem.. De hoge luchtvochtigheid in de nacht bij bedrijf H komt overeen met de

La classe des pointes à base retouchée clöture l'éventail des armatures carac- téristiques de l'Ourlaine: 35 pièces, soit 13,4%; différentes variétés s 'y rencon- trent:

Het verschil tussen de archivalische en de reconstructiegegevens kan erop wij- zen dat er in de grafkelder oorspronkelijk zes bijzettingen van vóór 1762 ondergebracht waren

Development of small-volume, microfluidic chaotic mixers for future application in two-dimensional liquid chromatography

Two-dimensional reversed-phase liquid chromatography using two monolithic silica C18 columns and different mobile phase modifiers in the two dimensions. Utilising retention

Micromixers with structures on channel walls: (A) Schematic diagram of slanted groove micromixer (SGM) and (B) (a) Staggered herringbone mixer (SHM) and (b) chaotic mixing patterns

Previous studies 24,25 showed that mixing performance of both slanted and herringbone grooves improves with an increase in the value of d/h, achieved using deeper grooves

SolidWorks© design of the compensation chip design with herringbone grooves representing different regions of the channel with different: (A) channel width; (B) groove and ridge