Continuous Flow Particle Focusing by AC-Actuation

Christina Tiflidis

1,2*

, Eiko Westerbeek

1,2

, Wouter Olthuis

2

, Jan Eijkel

2

, Wim De Malsche

1 1Department of Chemical Engineering, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussels, Belgium

2BIOS Lab-on-a-Chip Group, MESA+ Institute for Nanotechnology, MIRA Institute for Biomedical Technology and Technical

Medicine, Max Planck Center for Complex Fluid Dynamics, University of Twente Enschede 7500AE, the Netherlands *Christina.Tiflidis@vub.be

• Fabrication of completely transparent microfluidic devices with ITO

embedded electrodes.

• Creation of AC-EOF perpendicular to pressure-driven flow.

• Particle focusing was found and characterized by microscopic

observation.

• Varying parameters:

1) Frequency

2) Amplitude

3) Axial flow velocity

4) Zeta potential

ABSTRACT

This work presents a fast and reproducible particle focusing technique by

AC-actuation perpendicular to pressure-driven flow. We attribute the

effect amongst others to the AC electroosmotic flow generated in the

system.

INTRODUCTION

EXPERIMENTAL

We use a unique chip design which is completely transparent, with indium

tin oxide (ITO) electrodes forming the top and bottom of the channel for

AC actuation.

Figure 1: Schematic illustration of the setup.

AC

Chip Dimensions

Width: 40 μm Depth: 20 μm

Length: 12 mm

Focusing experiments with 2 types of 0.5 μm diameter PS particles

0.0025% w/v suspensions in unbuffered KNO

3

solution (0.1 mM, pH 6.2):

• Non-modified (ζ-potential -47.5 mV)

• PVA-coated (ζ-potential -22 mV)

RESULTS & DISCUSSION

• Focusing occurred in a time span of 0.17 s (1 V) to 1.5 s (0.25 V) without axial

flow and 0.07 s (1 V) to 0.09 s (0.25 V) at max. axial flow velocity (62.5 mm/s).

• The bead focusing velocity was found to scale with applied voltage as V1.5.

• For the PVA-coated particles, the focusing velocity increased faster with flow

velocity than for non-modified PS particles.

ACKNOWLEDGMENTS

This work has been supporting by the European Research Council through the Starting ERC Grant EVODIS 2020. The author wants to thank J.G. Bomer, H. Le The, V. Papadimitriou and J.T. Loessberg-Zahl for their support.

REFERENCES

[1] Y. W. Kim et al., Lab Chip, 2009, 9, 1043-1045.

[2] N. G. Green et al., Physical Review, 2002, E66, 026305 [3] N. Islam et al., Microfluid Nanofluid, 2007, 3:369-375

[4] M. Talebi et al., Presented Eurosensors 2017 Conference, Paris

• The focusing phenomenon, focusing speed and the dependence on

axial flow velocity are surprising.

• Is the particle focusing caused by AC-EOF as a stagnation point in the

center line, is it a dielectrophoretic effect or combination of both? This

will be further investigated by a newly developed 3D-PIV technique.

• We think this particle focusing device has great potential for versatile,

generic and rapid (bio)particle focusing.

CONCLUSIONS

SIMULATIONS

Sinusoidal AC-potentials 0.25 to 1 V peak-peak & 1 kHz frequency

Applied by a function generator

Focusing depends on:

• Axial flow velocity

• Particle size / ζ-potential / concentration • Frequency / potential amplitude

No theory for focusing yet, only AC-EOF explained 1) Focusing at low axial velocity 1.56 mm/s

Series of overlaid frames

Figure 3: Average electro-osmotic flow over a full cycle, the color map shows the magnitude of the flow and the arrow field the direction.

Figure 2: Schematic illustration of the electroosmotic-flow during half a cycle, in the

second half of the cycle the direction of the field changes as well as the sign of the charge on the electrodes. Therefore the direction of the flows stays the same. Inset: SEM-Image

2) Focusing at high axial velocity of 62.5 mm/s Series of overlaid frames

Visual

recording Fluorescence

intensity profiles across channel with & without AC-actuation

Fluorescence

intensity profiles with & without

AC-actuation Visual

recording

View publication stats View publication stats

Referenties

GERELATEERDE DOCUMENTEN

Een biologische veehouder moet door het leveren van gezond voedsel met zijn bedrijf binnen de regels voor biologische veehouderij de kost verdienen met gezonde dieren die lang

The purpose of the study is to determine the knowledge of pregnant women that attend antenatal clinic at the hospital about the prevention of Mother to Child Transmission (PMTCT)

gaan zakken.Dit komt doordat de buis verder gedeformeerd wordt en dus korter wil worden.De afdichting gaat verloren, de druk valt weg en de proef is

De hoeveelheid Nmin in deze laag was in de maanden mei en juli, maar vooral in de maand juni, bij beregening aan de hand van de DACOM-bodemvochtsensor veel hoger dan bij

In the present study, mild alkaline (NaOH) and dilute sulphuric acid conditions were used to extract hemicelluloses from Eucalyptus grandis, giant bamboo (Bambusa balcooa)

Thus, for any avoidance of doubt, the arm’s length principle that the Commission applies in its State aid assessment is not that derived from Article 9 of the OECD Model

The literature that has been studied concerns subjects like chemical (trace) elements, isotopic Pb, Sr and Nd research and composition, glass composition,

The numerical prediction of ACEO flow is compared to experimental observations in terms of the velocity above the electrode surface.. A correction factor will be introduced to match