Decentralized (bio)gas storage design with small scale MTT/CAES/TES (C5, WP2)

M. de Rooij, F. Koopman, H. van Weerden (Hanze), R. de Boer (ECN), C. Pelletier (Hanze)

Acknowledgements

The authors are grateful for the valuable contribution of the MSc students in Renewable Energy engineering and the Bachelor students in (Flexible) Energy (Technology) engineering.

Method

Preliminary Results

Preliminary conclusions and future research

Based on wind speed, irradiance patterns and electricity and heat demand patterns for a case of 100 households, we found the optimum dimensions for the decentralized (bio)gas storage based on guaranteed supply. We concluded that a decentralized (bio)gas storage of 85 000 Nm3 was needed to provide the heat demand. LNG was the most energy effi-cient storage technology for such dimensions.

The use of (bio)gas directly in a CHP (P/Q ratio = 2/3) that was mainly heat driven, resulted in a continuous overproduction of electricity due to the dominant heat demand of the 100 households in the Netherlands.This does not leave any room for the increase in the application of PV and wind generators, nor is there a purpose for electricity storage.

For that reason we will further investigate the application of a decentralized (bio)gas storage with MTT/CAES/TES as a solution to balance a renewable integrated network. Using an MTT in the system offers a more useful P/Q ratio for households of 1/5.

Introduction

The increase in renewable energy sources will require an increase in the operational flexibility of the grid, due to the intermittent nature of these sources. This can be achieved for the gas and the electricity grid, which are integrated by means of power-to-gas and vice versa, by applying gas and other energy storages. Because renewables are applied on a decentralized scale level and syngas and biogas are produced at relatively low pressures, we study the application of a decentralized (bio)gas storage system combined with

Micro Turbine Technology (MTT), Compressed Air Energy Storage (CAES) and Thermal Energy Storage (TES) units, which are designed to optimize energy efficiency. In this study we answer the following research questions:

a. What is the techno-economical feasibilty of applying a decentralized (bio)gas storage with a MTT/CAES/TES system to balance the integrated renewable energy network? b. How should the decentralized (bio)gas storage with MTT/CAES/TES system be designed, so that the energy efficient application in such networks is optimized?

Note that:

c. We verify the calculations for the small scale MTT unit with measurements on our proof-of-principle set-up of part of the system that includes two MTTs in parallel.

References

1 Ramakumar R., Sudhakara Shetty P., Ashenayi K., 1986, A linear programming approach to the design of integrated renewable energy systems for developing countries, IEEE

Transactions on Energy Conversion, Vol. EC-1, No. 4, December 1986

2 W. P. J. Visser, S. Shakariyants, M.T.L. de Later, A. Haj Ayed, K. Kusterer, 2012, Performance optimization of a 3 kW microturbine for CHP applications, Proceedings of ASME

Tur-bo Expo 2012, GT2012-68686

b. Thermodynamical system analysis

The thermodynamic model consists of components of a decentralized (bio)gas storage with MTT/CAES/TES system (Figure 2). Calculations are based on:

- System dimensions obtained from answering a.

- System functions for the system, units, components - Energy functions for the system, units, components - Mathematical thermal optimization equation

Figure 2. The decentralized (bio)gas storage with MTT/CAES/TES system consists of various units.

b. Thermodynamical system analysis

The 85,000 m3 of biogas that is required for the heat-ing demand is obtained from a (bio)gas storage system. Out of 4 different storage technologies (CNG, ANG,

LNG and NGH), LNG scored the highest on volume re-duction, energy efficiency and simplicity.

The continuous overproduction of electricity due to the dominant heat demand does not leave any room for

CAES. Therefore, we performed a thermodynamic anal-ysis of a CAES unit for the electricity grid only(Figure 5).

Figure 5. The thermodynamic results of a downscaled CAES unit which is part of an all electric renewable energy network.

c. Thermodynamic MTT measurements

Due to the dominant heat demand in the Netherlands, the CHP with a P/Q ratio = 2/3 causes a constant over-production of electricity. This does not leave any room for additional renewabel energy sources on the grid. Small scale MTT offers a solution with its P/Q ratio = 1/5. We measured the temperatures and pressures for the MTT gasturbine cycle and the water heat exchanger which are given in a system layout in Figure 6.

Figure 6. The thermodynamic data of a recuperated MTT under full load conditions (2.5 kWe and 15 kWth)

1 Recuperated MTT P1 1 bar T1 290 K P2 3 bar T3 980 K T5 1060 K T7 330 K Heat exchanger Ta 36°C Tb 52°C 2 3 4 5 6 7 A B

a. Techno-economical system analysis

The integrated grid with a decentralized (bio)gas stor-age with MTT/CAES/TES system is modeled based on

linear programming1. We obtain the dimensions of this

energy network so that the costs (CAPEX and OPEX) are minimized. The primary energy sources (wind, solar and biomass) are balanced with the energy consump-tion of average Dutch household neighbourhoods in Eelde (Figure 1).

Figure 1. The integrated grid with decentralized (bio)gas storage is mod eled with conversion and energy storages.

c. Thermodynamic MTT measurements

To verify the thermodynamic calculations for the MTT system2, we build a proof-of-principle set-up that con-sists of 2 MTTs in parallel with a cooling system to dis-charge the heat (Figure 3).

The recuperated MTT produces 1.2-3 kWe and 7-15 kWth at an efficiency that is reported to be 87% maxi-mum, depending on the water conditions.

Figure 3.The P&ID of the proof-of-principle MTT set-up with a cooling system to discharge the heat.

a. Techno-economical system analysis

As an example, we studied a case that consists of 100 households with a yearly demand of 3500 KWhe and 40 GJh each. We assumed the yearly electricity demand to be supplied by wind energy (30%), solar energy (20%) and biogas (50%).

The hourly supply and demand were supposed to be balanced by a CHP (Figure 4). However, because the heat demand, which is met by a supply of 85,000 Nm3 biogas via the CHP, is dominant in The Netherlands, there is a continuous over production of electricity.

Figure 4.Energy production from various renewable energy sources. The supply and demand is matched with biogas combustion in a CHP.

Biomass v1 v3 v4 v3 v0 v1 (1/4 h basis) Wind Local Imported Φgas Pel Φmin Φmax Φdesign Solar Storage Storage Storage Pη Pel ΦgasPtherm Pη Pη Pel Pel P v v t Φgas t P t Pel Turbine MV LV Distribution

Referenties

GERELATEERDE DOCUMENTEN

Een en ander betekent dat de Regering het beschik­ bare budget voor de koopkrachttoeslag voor 1985 zal moeten uitbreiden van 300 miljoen naar ± 500 miljoen wil aan deze

For the value proposition, it is assumed that the network operator uses the UGS for balancing (B). For the upfront requirements, the network operator also needs exemption from TPA

In addition, very high transmi ssion tariffs in The Netherlands are anyhow detrimental to the business case of gas storages, illustrated by the decision of I

The second method is to use the PH algorithm and on top of that use Lagrangian relaxation on the storage constraint such that the problem becomes separable in the number of

The first approach examining daily changes in the natural gas price tries to answer the sub question ‘What are the main factors influencing daily changes in

BAR values obtained after training classifiers on the first dataset suggest two ideas: (1) overall, features extracted from semi-manual delineations are better than features

Other components that were also investigated in the original literature study for this project is the storage batteries, charge controller, additional energy

Although not contained within the project’s scope, an additional analysis of the effect of the wind data’s resolution on the probable power output of a wind turbine was