CH
3HgCl <1
CH
3CH
2HgCl <1
Extractable inorganic
Mercury 6.1
Non-extractable Mercury
Semi-mobile Mercury 21
Non-mobile Mercury <1
Test Report No. IAC19-06961 Date : 15/10/19 Page 3 of 3
SGS Belgium NV Institute for Applied Chromatography Haven 407 Polderdijkweg 16 B-2030 Antwerpen
IAC19-06961.002 GP19-28430.002
Operationally-Defined Mercury Fractions Individual Mercury Species
Results (ppm) Total Mercury
Extractable Mercury
Extractable organic Mercury
CH
3HgCl <1
CH
3CH
2HgCl <1
Extractable inorganic
Mercury 2.2
Non-extractable Mercury
Semi-mobile Mercury 9.1
Non-mobile Mercury <1
IAC19-06961.003 GP19-28430.003
Operationally-Defined Mercury Fractions Individual Mercury Species
Results (ppm) Total Mercury
Extractable Mercury
Extractable organic Mercury
CH
3HgCl <1
CH
3CH
2HgCl <1
Extractable inorganic
Mercury 2.6
Non-extractable Mercury
Semi-mobile Mercury 8.3
Non-mobile Mercury <1
ANALYSERAPPORT
GP19-33579
LABORATORIUM
Laboratorium Laboratorium manager
Adres
Telefoon Fax Email SGS referentie Gerapporteerd
+31 (0) 88 214 62 00 +31 (0) 88 214 62 99 nl.envi.cs@sgs.com
29-10-2019 Spoorstraat 12 Postbus 78
4430 AB 's-Gravenpolder
GP19-33579 Aanvraag Ontvangen 21-10-2019
KLANT Klant Ref
Contactpersoon Bram Vanhumbeeck
OVAM REALISATIE EN SANERING
Bestek RC140501
Grote Laak Tessenderlo grond Stationstraat 110
2800 MECHELEN BELGIUM
+32 473 66 87 59
bram.vanhumbeeck@aecom.com Rudi Herman
Environment, Health and Safety SGS Belgium NV
ADDITIONELE OPDRACHT INFO
Projectnummer Grote Laak Tessenderlo
MONSTER IDENTIFICATIE
GP19-33579.001 GL1.1-VDA-N-B1 (0,5-1,0) GP19-33579.002 GL1.1-VDA-N-B1 (1,0-1,5)
GP19-33579.003 GL1.1-VDA-N-B2 (0,5-1,0) "verdere oever"
GP19-33579.004 GL1.1-VDA-N-B2 (1,0-1,5) "verdere oever"
GP19-33579.005 GL1.2-VDA-N-B1 (0,5-1,0) GP19-33579.006 GL1.2-VDA-N-B1 (1,0-1,5) GP19-33579.007 GL1.3-VDA-N-B1 (0,5-1,0) GP19-33579.008 GL1.3-VDA-N-B1 (1,0-1,5) GP19-33579.009 GL1.3-VDA-Z-B1 (0,5-1,0) GP19-33579.010 GL1.3-VDA-Z-B1 (1,0-1,5) GP19-33579.011 GL1.4-VDA-N-B1 (0,5-1,0) GP19-33579.012 GL1.4-VDA-N-B1 (1,0-1,5) GP19-33579.013 GL1.4-VDA-N-B1 (1,5-2,0) GP19-33579.014 GL1.5-VDA-N-B1 (0,5-1,0) GP19-33579.015 GL1.5-VDA-N-B1 (1,0-1,5) GP19-33579.016 GL1.5-VDA-Z-B1 (0,5-1,0) GP19-33579.017 GL1.5-VDA-Z-B1 (1,0-1,5) GP19-33579.018 Slibvang-VDA-Z-B1 (0,5-1,0) GP19-33579.019 Slibvang-VDA-Z-B1 (1,3-1,5)
OPMERKINGEN
De analyses gemarkeerd met een Q zijn ISO17025 geaccrediteerd (BELAC 005-TEST)
De analyses gemarkeerd met een (A) zijn uitgevoerd op de SGS locatie: Polderdijkweg 16 te Antwerpen.
Het laboratorium beschikt over een erkenning voor de met een E gemarkeerde analyses.
ANALYSERAPPORT
GP19-33579
HANDTEKENINGEN
Rudi Herman
Lab Operations Manager
ISO17025 (BELAC 005-TEST)
Behoudens andersluidende overeenkomst worden alle opdrachten en documenten uitgevoerd en uitgegeven op basis van onze algemene voorwaarden. Op eenvoudig verzoek worden deze voorwaarden opnieuw aan u toegezonden. De aandacht wordt gevestigd op de beperking van aansprakelijkheid, de vergoedings-en bevoegdheidskwesties bepaald door deze voorwaarden. Elke houder van dit document dient te weten dat de informatie vervat in dit document enkel de bevindingen van SGS op het ogenblik van haar tussenkomst en binnen de grenzen van de eventuele instructies van de opdrachtgever, bevat. SGS is enkel aansprakelijk ten aanzien van haar opdrachtgever en dit document stelt de bij een handelstransactie betrokken partijen niet vrij van hun plicht al hun rechten en verplichtingen uit te oefenen voortspruitend uit de handelsdocumenten.
Elke niet toegestane wijziging evenals de namaak of vervalsing van de inhoud of het uitzicht van dit document is onwettig en overtreders zullen vervolgd worden.
Indien het/de monster(s) waarop de resultaten van dit rapport betrekking hebben werd(en) genomen en /of aangeleverd door de klant of door een derde partij, voorgedragen door de klant, dan houden de resultaten geen enkele waarborg in voor de representativiteit van welke goederen dan ook en hebben enkel betrekking op het/de monster(s). SGS aanvaardt geen enkele aansprakelijkheid met betrekking tot de oorsprong van het /de monster(s), waarvan het/ze beweerd wordt afkomstig te zijn.
Prestatiekenmerken van geaccrediteerde verrichtingen zijn opvraagbaar. In de bijlage is informatie vermeld over de houdbaarheid en conserveringsaspecten van de aangeleverde monsters. Toelichting op
ANALYSERAPPORT
GP19-33579
Monsternummer GP19-33579.001 GP19-33579.002 GP19-33579.003 GP19-33579.004 GP19-33579.005
Matrix Grond Grond Grond Grond Grond
Bemonsteringsdiepte
Bemonsterd door Aecom Aecom Aecom Aecom Aecom
Bemonsteringsdatum 17-10-2019 17-10-2019 17-10-2019 17-10-2019 17-10-2019 Bemonsteringsplaats
Ontvangstdatum Monster 18-10-2019 18-10-2019 18-10-2019 18-10-2019 18-10-2019
Parameter Eenheid RG Resultaat Resultaat Resultaat Resultaat Resultaat
Metalen [Analyse CMA/2/I/B.1/Destructie CMA/2/II/A.3] (A)
4.0
mg/kg ds 250 79 39 180 74
Q/E Arseen
0.40
mg/kg ds 3.8 6.6 1.6 0.67 <0.40
Q/E Cadmium
15
mg/kg ds 66 80 74 110 66
Q/E Chroom
5.0
mg/kg ds 72 26 5.1 7.0 <5.0
Q/E Koper
13
mg/kg ds 170 350 160 110 80
Q/E Lood
3.0
mg/kg ds 18 17 13 7.4 5.8
Q/E Nikkel
20
mg/kg ds 580 220 85 80 46
Q/E Zink
Kwik [Analyse CMA/2/I/B.3/Destructie CMA/2/II/A.3] (A)
0.10
mg/kg ds 4.0 23 13 7.0 4.7
Q/E Kwik
Droge stof [Conform CMA 2/II/A.1]
-gew % 46.4 52.6 72.6 66.4 65.1
Q/E Droge stof
ANALYSERAPPORT
GP19-33579
Monsternummer GP19-33579.006 GP19-33579.007 GP19-33579.008 GP19-33579.009 GP19-33579.010
Matrix Grond Grond Grond Grond Grond
Bemonsteringsdiepte
Bemonsterd door Aecom Aecom Aecom Aecom Aecom
Bemonsteringsdatum 17-10-2019 17-10-2019 17-10-2019 17-10-2019 17-10-2019 Bemonsteringsplaats
Ontvangstdatum Monster 18-10-2019 18-10-2019 18-10-2019 18-10-2019 18-10-2019
Parameter Eenheid RG Resultaat Resultaat Resultaat Resultaat Resultaat
Metalen [Analyse CMA/2/I/B.1/Destructie CMA/2/II/A.3] (A)
4.0
mg/kg ds 77 73 660 82 39
Q/E Arseen
0.40
mg/kg ds 0.95 <0.40 16 9.0 0.92
Q/E Cadmium
15
mg/kg ds 63 81 86 110 82
Q/E Chroom
5.0
mg/kg ds 9.7 7.5 89 6.5 <5.0
Q/E Koper
13
mg/kg ds 100 94 770 42 17
Q/E Lood
3.0
mg/kg ds 12 23 28 12 9.8
Q/E Nikkel
20
mg/kg ds 110 110 530 260 100
Q/E Zink
Kwik [Analyse CMA/2/I/B.3/Destructie CMA/2/II/A.3] (A)
0.10
mg/kg ds 1.7 1.2 34 1.0 0.29
Q/E Kwik
Droge stof [Conform CMA 2/II/A.1]
-gew % 52.8 41.1 52.3 43.3 48.8
Q/E Droge stof
ANALYSERAPPORT
GP19-33579
Monsternummer GP19-33579.011 GP19-33579.012 GP19-33579.013 GP19-33579.014 GP19-33579.015
Matrix Grond Grond Grond Grond Grond
Bemonsteringsdiepte
Bemonsterd door Aecom Aecom Aecom Aecom Aecom
Bemonsteringsdatum 17-10-2019 17-10-2019 17-10-2019 17-10-2019 17-10-2019 Bemonsteringsplaats
Ontvangstdatum Monster 18-10-2019 18-10-2019 18-10-2019 18-10-2019 18-10-2019
Parameter Eenheid RG Resultaat Resultaat Resultaat Resultaat Resultaat
Metalen [Analyse CMA/2/I/B.1/Destructie CMA/2/II/A.3] (A)
4.0
mg/kg ds 210 61 250 23 32
Q/E Arseen
0.40
mg/kg ds 1.5 <0.40 3.1 0.50 0.48
Q/E Cadmium
15
mg/kg ds 49 62 45 26 40
Q/E Chroom
5.0
mg/kg ds 7.2 <5.0 19 7.4 6.5
Q/E Koper
13
mg/kg ds 130 39 200 22 26
Q/E Lood
3.0
mg/kg ds 6.2 4.6 8.4 5.0 7.8
Q/E Nikkel
20
mg/kg ds 93 37 240 52 62
Q/E Zink
Kwik [Analyse CMA/2/I/B.3/Destructie CMA/2/II/A.3] (A)
0.10
mg/kg ds 5.8 2.8 6.9 0.75 1.1
Q/E Kwik
Droge stof [Conform CMA 2/II/A.1]
-gew % 78.0 79.3 60.6 86.9 88.3
Q/E Droge stof
ANALYSERAPPORT
GP19-33579
Monsternummer GP19-33579.016 GP19-33579.017 GP19-33579.018 GP19-33579.019
Matrix Grond Grond Grond Grond
Bemonsteringsdiepte
Bemonsterd door Aecom Aecom Aecom Aecom
Bemonsteringsdatum 17-10-2019 17-10-2019 17-10-2019 17-10-2019 Bemonsteringsplaats
Ontvangstdatum Monster 18-10-2019 18-10-2019 18-10-2019 18-10-2019
Parameter Eenheid RG Resultaat Resultaat Resultaat Resultaat
Metalen [Analyse CMA/2/I/B.1/Destructie CMA/2/II/A.3] (A)
4.0
mg/kg ds 100 44 19 21
Q/E Arseen
0.40
mg/kg ds 2.0 1.6 <0.40 <0.40
Q/E Cadmium
15
mg/kg ds 40 50 80 92
Q/E Chroom
5.0
mg/kg ds 54 68 <5.0 <5.0
Q/E Koper
13
mg/kg ds 99 64 35 <13
Q/E Lood
3.0
mg/kg ds 12 13 9.3 14
Q/E Nikkel
20
mg/kg ds 400 520 35 38
Q/E Zink
Kwik [Analyse CMA/2/I/B.3/Destructie CMA/2/II/A.3] (A)
0.10
mg/kg ds 3.6 0.99 0.67 <0.10
Q/E Kwik
Droge stof [Conform CMA 2/II/A.1]
-gew % 84.2 88.3 82.5 78.4
Q/E Droge stof
ANALYSERAPPORT
GP19-33579
BIJLAGE
HOUDBAARHEIDS- EN CONSERVERINGS OPMERKINGEN
Alle monsters zijn correct geconserveerd bij het laboratorium aangeleverd.