• No results found

University of Groningen Articulation issues in total hip arthroplasty van der Veen, Hugo Christiaan

N/A
N/A
Protected

Academic year: 2021

Share "University of Groningen Articulation issues in total hip arthroplasty van der Veen, Hugo Christiaan"

Copied!
6
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

University of Groningen

Articulation issues in total hip arthroplasty

van der Veen, Hugo Christiaan

IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from

it. Please check the document version below.

Document Version

Publisher's PDF, also known as Version of record

Publication date:

2018

Link to publication in University of Groningen/UMCG research database

Citation for published version (APA):

van der Veen, H. C. (2018). Articulation issues in total hip arthroplasty. Rijksuniversiteit Groningen.

Copyright

Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons).

Take-down policy

If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum.

(2)

ARTICULATION ISSUES IN

TOTAL HIP ARTHROPLASTY

(3)

ter verkrijging van de graad van doctor aan de Rijksuniversiteit Groningen

op gezag van de

rector magnificus prof. dr. E. Sterken en volgens besluit van het College voor Promoties.

De openbare verdediging zal plaatsvinden op woensdag 18 april 2018 om 14:30 uur

door

Hugo Christiaan van der Veen

geboren op 23 januari 1978 te Ommen

Articulation Issues in

Total Hip Arthroplasty

Proefschrift

Financial support for the publication of this thesis was provided by:

Anna Fonds | NOREF

Nederlandse Orthopaedische Vereniging Research Institute SHARE

Universitair Medisch Centrum Groningen / Rijksuniversiteit Groningen Wetenschapsfonds Martini Ziekenhuis Groningen

ISBN

978-94-034-0537-7(Printed book) 978-94-034-0536-0 (PDF without DRM)

Cover & lay-out design

www.proefschriftopmaak.nl, Groningen

Print

Netzodruk Groningen

© 2018, Hugo C. van der Veen, Groningen, the Netherlands. All rights reserved.

No part of this thesis may be reproduced or transmitted in any form or by any means without the prior permission of the copyright owner.

(4)

Promotor

Prof. dr. S.K. Bulstra

Copromotores

dr. J.J.A.M. van Raay dr. I.H.F. Reininga

dr. I. van den Akker-Scheek

Beoordelingscommissie

Prof. dr. R.G.H.H. Nelissen Prof. dr. ir. N.N.J. Verdonschot Prof. dr. R.A.J.O. Dierckx

(5)

11 23 37 55 73 91 109

CONTENTS

Chapter 1

General introduction and aims

PART I - ACETABULAR COMPONENT FIXATION Chapter 2

Is there evidence for accelerated polyethylene wear in uncemented compared to cemented acetabular components?

A systematic review of the literature Chapter 3

Clinical outcome, survival and polyethylene wear of an uncemented total hip arthroplasty

A 10- to 12-year follow-up study of 81 hips PART II - BEARING CHARACTERISTICS Chapter 4

Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results

Chapter 5

Pseudotumour incidence, cobalt levels and clinical outcome after large head metal-on-metal and conventional metal-on-polyethylene total hip arthroplasty

Mid-term results of a randomised controlled trial Chapter 6

Pseudotumour incidence, cobalt levels and clinical outcome after small head metal-on-metal and conventional metal-on-polyethylene cemented total hip arthroplasty

Long-term results of a randomised controlled trial Chapter 7

(6)

117 127 138 141 142 Chapter 8

Summary and samenvatting

APPENDIX

Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty:

design of a randomised controlled trial Dankwoord

Peer-reviewed publicaties Research Institute SHARE

Referenties

GERELATEERDE DOCUMENTEN

Increased revision rates were also reported by the Norwegian Arthroplasty Register in the medium-term to long-term follow- up, attributed to wear and osteolysis in modular

A complete 10- to 12-year follow-up of an uncemented total hip arthroplasty (THA) was performed regarding survival, clinical outcome, polyethylene wear and influencing factors

Serum cobalt, chromium and titanium ion levels were not related to bone density, nor to acetabular inclination or femoral head size.. Oxford and Harris hip scores were similar in

Pseudotumour incidence, cobalt levels and clinical outcome after large head metal-on-metal and conventional metal-on-polyethylene total hip arthroplasty.. Mid-term results of

We report good implant survival in cemented head-taper matched small head MoM THA after 13.4 years of clinical follow-up with a low incidence of pseudotumour formation and

The third aim was to compare large head MoM THA with small head (28 mm) MoP THA regarding tissue reactions, metal ions and functional performance (short- and medium-term

Cemented small head MoM THA was compared with cemented MoP THA (both with 28 mm femoral head diameters) in a long-term follow-up regarding tissue reactions, metal ions and

This randomized controlled trial has been designed to determine wear, bone mineral density, functional outcome and survival in reversed hybrid total hip arthroplasty comparing