Objective clinical performance outcome of total knee prostheses. A study of mobile bearing knees using fluoroscopy, electromyography and roentgenstereophotogrammetry

Garling, E.H.

Citation

Garling, E. H. (2008, March 13). Objective clinical performance outcome of total knee prostheses. A study of mobile bearing knees using fluoroscopy, electromyography and roentgenstereophotogrammetry. Retrieved from https://hdl.handle.net/1887/12662

Version: Corrected Publisher’s Version

License: Licence agreement concerning inclusion of doctoral thesis in the Institutional Repository of the University of Leiden Downloaded

from: https://hdl.handle.net/1887/12662

Note: To cite this publication please use the final published version (if applicable).

(2)

Objective Clinical Performance Outcome of Total Knee Prostheses

A study of mobile bearing knees using fl uoroscopy, electromyography and roentgenstereophotogrammetry

E.H. Garling

UITNODIGING

Op donderdag 13 maart 2008 om 15.00 uur zal ik mijn proefschrift

‘Objective Clinical Performance Outcome of Total Knee

Prostheses’

in het openbaar verdedigen in Groot Auditorium Rapenburg 93, Leiden.

Aansluitend is er een receptie in de Faculty Club, Rapenburg 6, Leiden.

Ik nodig U en Uw partner van harte uit om deze promotie

bij te wonen.

Eric Garling Rhijngeesterstraatweg 114

2343 BZ Oegstgeest 071 - 517 56 23 Eric.Garling@gmail.com

Paranimfen:

Leon Kee (06 - 457 76 800)

Daaf Roukens (DaafRoukens@gmail.com)

Objective Clinical Performance Outcome of Total Knee Prostheses E.H. Garling

Referenties

GERELATEERDE DOCUMENTEN

During the 20-60% interval of the single limb support, MB patients showed a signifi cant higher level of fl exor activity, resulting in a lower net joint moment,

Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty: prospective randomized comparison of hydroxyapatite- coated and cemented

Hydroxyapatite coating versus cemented fixation of the tibial component in total knee arthroplasty: Prospective randomized comparison of hydroxyapatite- coated and cemented

Th e low variability of the data in the MB knee prosthesis group suggests that implantation of a MB design is more predictable and forgiving with respect to micromotion of the

Th e post of the tibial insert was fractured and severe fatigue wear with subsurface deformation and removal of the surface was observed at the anterior part of the post

Gait analysis, with skin mounted marker tracking and force plates, is a well-established objective method for the acquisition of kinematic and kinetic data of total knee

In Chapter 6 the diff erences of electromyography activity of the muscles stabilizing the knee joint between patients with a mobile bearing knee prosthesis and a posterior

In alle patiënten liet het bovenbeen een grotere axiale rotatie zien dan het roterende lager waarmee werd aangetoond dat het bovenbeen component van de prothese glijdt over