91 SUMMARY
Cardiopulmonary bypass (CPB) is a technique that makes open heart surgery possible.
When CPB is used the heart can be stopped while the blood circulation, oxygen delivery and carbon dioxide removal are guaranteed. In the last decades CPB has become much safer but still causes a systemic inflammation reaction (SIRS). SIRS may cause morbidity and, when severe, even mortality. SIRS reaction is worse in neonates and infants due to the immaturity of organs and the unfavourable ratio of CPB prime volume to patient circulating volume. This thesis focuses on different techniques that have been developed to decrease the deleterious effects of CPB in pediatric cardiac surgery.
In chapter 2 we describe the technique of modified ultrafiltration (MUF). This technique, described for the first time in 1991 by Naik and Elliott, is designed to reverse the
hemodilution created during CPB. After the cessation of CPB excess water is removed by using an ultrafilter thus providing a higher hematocrit at the end of the procedure. We compared in a retrospective way 2 groups of 99 patients each, in one group we used MUF and in the other group ultrafiltration was not used. We concluded that modified
ultrafiltration decreases blood transfusion requirements and chest drain loss after pediatric cardiac surgery.
The ratio between CPB prime solution and circulating blood volume is highest in the neonatal patient. It has been reported that neonates have a poor antioxidative and iron binding capacity. During CPB, prooxidative substances, such as nonprotein-bound iron, are released while the plasma antioxidant capacity decreases, resulting in excess
accumulation of deze afkorting voluit opschrijven!Radical Oxygen Species. In chapter 3 and 4 we describe the antioxidative capacity of CPB prime based on human albumin or fresh frozen plasma. We have demonstrated that a prime based on fresh frozen plasma has higher antioxidative and iron, Hb/Heam binding capacities.
Contact of blood with the non-biological surfaces of the CPB system has been designated as the main cause of complement activation. Improving the biocompatibility of CPB
92
systems by means of decreasing the contact activation of blood elements and thereby attenuating the inflammatory response is evidently desired, and for this reason several coatings have been developed. In chapter 5 we investigated the PHISIO® coating in neonatal CPB. We were not able to show any differences between a coated and an uncoated CPB system in this prospective randomized study.
In chapter 6 we describe the results of the use of dexamethasone in both coated and uncoated CPB systems. Information is lacking about the interaction of medication and the CPB prime or the coating of a CPB system. We did not observe any interaction between dexamethasone and the PHISIO® coating, but have observed that in the group with PHISIO® coating without dexamethasone the production of IL-8 was significantly increased.
In literature many controversies are found on the topic of CPB coatings. It is difficult to compare these studies due to different patient groups, differences in measured parameters and lack of proper control groups. Chapter 7 reviews the literature on the use of CPB coatings both in vitro and in vivo.