• No results found

Roentgen stereophotogrammetric analysis to study dynamics and migration of stent grafts

N/A
N/A
Protected

Academic year: 2021

Share "Roentgen stereophotogrammetric analysis to study dynamics and migration of stent grafts"

Copied!
9
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

Roentgen stereophotogrammetric analysis to study dynamics and migration of stent grafts

Koning, O.H.J.

Citation

Koning, O. H. J. (2009, June 25). Roentgen stereophotogrammetric analysis to study dynamics and migration of stent grafts. Retrieved from https://hdl.handle.net/1887/13870

Version: Corrected Publisher’s Version

License: Licence agreement concerning inclusion of doctoral thesis in the Institutional Repository of the University of Leiden

Downloaded from: https://hdl.handle.net/1887/13870

Note: To cite this publication please use the final published version (if applicable).

(2)

Roentgen stereophotogrammetric analysis to study

dynamics and migration of stent-grafts

Olivier H.J. Koning

(3)

Printing of this thesis was financially supported by:

Medtronic Trading BV, W.L. Gore &Associates, Angiocare, Vascutek Nederland BV, Abbott Vascular BV, Medis specials bv, B.Braun, LeMaitre Vascular, Bard Medical, Baxter

Copyright: Olivier H.J. Jan Koning ©2009 ISBN 978-90-8559-527-4

Cover, Lay-out and printing: Optima Grafische Communicatie, Rotterdam, The Netherlands Front: Pulsatile model for stent-graft migration measurement (photograph: O.H.J. Koning)

Back: Schematic representation of reconstruction of the position of stent-graft markers (B.L. Kaptein)

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronically, mechanically, by photocopying, recording or otherwise, without the prior written permission of the author.

(4)

Roentgen Stereophotogrammetric Analysis to study

Dynamics and Migration of Stent-Grafts

PROEFSCHRIFT

ter verkrijging van

de graad van Doctor aan de Universiteit Leiden, op gezag van Rector Magnificus prof. mr. P.F. van der Heijden,

volgens besluit van het College voor Promoties te verdedigen op donderdag 25 juni 2009

klokke 15.00 uur

door

Olivier Henk Jan Koning geboren te Amsterdam

in 1970

(5)

Promotiecommissie:

Promotor: Prof. Dr. J.H. van Bockel Copromotor: Dr. E.R. Valstar

Referent: Prof. Dr. M. Malina (UMAS, Malmo University Hospital, Malmo, Zweden)

Overige leden: Prof. Dr. J.F. Hamming Prof. Dr. J.H.C. Reiber

Prof. Dr. H.J.M. Verhagen (Erasmus Medisch Centrum, Rotterdam)

(6)

Voor Wally

Aan Wally, Charlotte en Juriaan

(7)
(8)

Contents

CHAPTER 1 9

General Introduction

CHAPTER 2 25

Technique of RSA and FRSA

PART I 37

Surveillance of stent-graft migration after EVAR

CHAPTER 3 39

Roentgen Stereophotogrammetric Analysis: an accurate tool to assess endovascular stent-graft migration

Journal of Vascular and Endovascular Therapy 2006;13:468-475

CHAPTER 4 53

Accurate detection of stent-graft migration in a pulsatile aortic model using Roentgen Stereophotogrammetric Analysis

Journal of Vascular and Endovascular Therapy 2007;14:30-38

CHAPTER 5 69

Roentgen Stereophotogrammetric Analysis to detect and quantify stent-graft migration in an animal model

Submitted

CHAPTER 6

Accurate Roentgen Stereophotogrammetric Analysis of stent-graft migration using a single aortic reference marker

81

Submitted

CHAPTER 7 93

Plain radiographic images have insufficient accuracy and precision to detect stent- graft migration

Submitted

(9)

PART II 105 Quantification of 3-D stent-graft dynamics using Fluoroscopic Roentgen

Stereophotogrammetric Analysis

CHAPTER 8 107

Assessment of 3-D stent-graft dynamics using Fluoroscopic Roentgen Stereophotogrammetric Analysis (FRSA)

Journal of Vascular Surgery 2007;46:773-779

CHAPTER 9 123

Fluoroscopic Roentgen Stereophotogrammetric Analysis (FRSA) to study 3-D stent- graft dynamics in patients, a pilot study

Journal of Vascular Surgery 2009, in press

ADDENDUM 139

EVAR and radiation risks

CHAPTER 10 141

Endovascular abdominal aortic aneurysm repair: patient dose and radiation risks Submitted

CHAPTER 11 155

Summary, future aspects and conclusions

CHAPTER 12 169

Samenvatting, toekomst perspectieven en conclusies

CHAPTER 13 181

Acknowledgements

List of publications by the author Curriculum Vitae

Referenties

GERELATEERDE DOCUMENTEN

Since RSA is proven to be highly accurate in a static environment, 9-13 RSA of the model with- out pulsatile circulation was used as the reference standard to determine

Thus, adding a marker to the aortic wall as a reference point for CT analysis facilitates highly accurate migration detection with CT analysis using 3D image reconstruction, and

To assess the accuracy of detection of stent-graft migration with RSA using one single aortic reference marker instead of a cluster of reference markers as is currently standard

The accuracy and precision of plain radiography for detection of stent-graft migration after EVAR is insufficient for clinical use, especially when early and accurate identification

License: Licence agreement concerning inclusion of doctoral thesis in the Institutional Repository of the University of Leiden. Downloaded

Fluoroscopic Roentgen Stereophotogrammetric Analysis (FRSA) enables highly accurate measurement of three dimensional motion of markers on a stentgraft in a pulsatile in-vitro

The changing position of the center of mass of the stent markers was used to quantify three-dimensional motion of the aorta – stent-graft complex during the cardiac

Justifica- tion of radiation exposure for patients undergoing abdominal endovascular aortic aneurysm repair (EVAR) implies that EVAR, and its associated preoperative planning