• No results found

VALIDATION AND VERIFICATION

N/A
N/A
Protected

Academic year: 2021

Share "VALIDATION AND VERIFICATION"

Copied!
24
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

IIORTH-WE$T IJilM:RSI'TY YUillllfSlTl YA llOKONE·BOPHIRIMA

t IOOru>WES-UIII\'EllSITfiT CHAPTER 6: VALIDATION AND VERIFICATION

VALIDATION AND VERIFICATION

6.1

INTRODUCTION

This chapter presents a comparison of the newly developed Multi-sphere Unit Cell Model results with various experimental results. The Multi-sphere Unit Cell and various other models where implemented in Engineering Equation Solver (EES) to obtain simulation results and can be found in Appendix G. The experimental data was chosen in order to validate all the separate effects contributing to heat transfer in a randomly packed bed. The separate effects, conduction and radiation in the bulk and wall regions, are generally verified using: (1) the spherical-flat contact experimental facility (Section C.1 ); (2) the spherical-spherical experimental facility (Section C.2); and (3) the High Temperature Oven (HTO) experimental test facility (Section C.3). In addition, the SANA-I experimental test facility constructed and operated at the Research Centre in JOiich in Germany (Section C.4) and the HITU experimental test facility constructed and operated at the North-West University in Potchefstroom was used to verify the integrated heat transfer effects in all the regions defined in a randomly packed bed. Summaries of the experimental tests used are presented in Table

6.1 to Table 6.3.

Table 6.1: Experimental tests used for the validation of the Multi-sphere Unit Cell Model in the bulk region

TEST THERMAL

RESEARCHERIS PACKING ENVIRONMENT SPECIMEN& SPHERE SIZE

MEAN BULK

PHENOMENON TYPE PARAMETERS POROSITY

SEPARATE EFFECTS IN BULK REGION

CONDUCTION Buonanno eta/.

sc

Air 100Cr1) Steel dp=19.05mm &=0.476

(BULK) (2003:251) FCC 1 atm Pressure, 101.358 kPa spheres dp=19.05mm &=0.2595

RADIATION Robold (1982:156) Random,

Breitbach & Barthels Vacuum Graphite dp=40mm li =0.39 (BULK)

(1980:392) Bulk Region

INTEGRATED EFFECTS IN BULK REGION

CONDUCTION +

Random, Helium

RADIATION Robold (1982:156) Graphite dp=40mm li =0.39

(BULK) Bulk Region 70 kPa - 85 kPa

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

135

OF A PACKED PEBBLE BED

(2)

IIORTfPN(SI UNl\1!1R$11Y YUtJIIlBHI YA OOKONE-BOPKHI:lMA

NOOROWES·Ul IWERSIT(IT CHAPTER 6: VALIDATION AND VERIFICATION

Table 6.2: Experimental tests used for the validation of the Multi-sphere Unit Cell Model in the wall region

THERMAL TEST

RESEARCHERIS ENVIRONMENT ·· SPECIMEN& SPHERE SIZE

PHENOMENON

PARAMETERS

SEPARATE EFFECTS IN WALL REGION

CONDUCTION Kitscha & Yovanovich 0.5d P from wall Carbon steel

(WALL) (1974:93) Argon, sphere, dp =25.4mm

0.073 kPa- 98.67 kPa Flat 1 020 steel

RADIATION Rabold (1982:156) 0.5d P from wall Graphite sphere dp=40mm

Breitbach & Barthels

(WALL) (1980:392) Vacuum Flat graphite

INTEGRATED EFFECTS IN WALL REGION

CONDUCTION + Rabold (1982:156) 0.5d p from wall

Graphite sphere

RADIATION Breitbach & Barthels Helium Flat graphite dp =40mm

(WALL) (1980:392) 70 kPa - 85 kPa

Table 6.3: Experimental tests used for the verification of the Multi-sphere Unit Cell Model in the wall, near-wall and bulk regions

,.,_

TEST

THERMAL TEST FACILITY ENVIRONMENT SPECIMEN& SPHERE SIZE

PHENOMENON PARAMETERS

CONDUCTION +

RADIATION SANA-I Helium, Graphite sphere dp=60mm

(WALL, NEAR-WALL 1atm

=

101.328 kPa

AND BULK)

CONDUCTION +

RADIATION HTTU Nitrogen Graphite sphere dp =60mm

(WALL, NEAR-WALL 10 kPa

AND BULK)

6.2

VALIDATION OF MULTI-SPHERE UNIT CELL IN THE

BULK REGION

In this section, the conduction and radiation components of the Multi-sphere Unit Cell Model in the bulk region are validated separately and integrally using data obtained by Buonanno et a/. (2003:251), Rabold (1982:154) and Breitbach & Barthels (1980:392).

Buonanno et a/. (2003:251) conducted experiments to determine the effective thermal conductivity through 1 00Cr6 steel spheres. Tests were conducted using SC- and FCC-packed structures with air as the interstitial gas at atmospheric conditions. The effective thermal conductivity results were then obtained by varying the root mean square surface roughness uRMS of the spheres from 0.03,um to 1.7 ,um, as well as the average applied force. The experimental setup is shown in Figure C.2.

The first experimental data set of Buonanno eta/. (2003:251} that is considered is that of the SC packing at a constant applied force ofF= 0.983N and the root mean square surface roughness uRMS varied, as displayed in Table C.4. The effective thermal conductivity between two spheres can be obtained by rewriting Eq. (5.34), in order to account for the SC

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

136

OF A PACKED PEBBLE BED

(3)

UORTI!-WEST IJIUVEI!SJTY

YUtllilESlTl YA BOKOUE-BOPHIRJMA

IIOOROW5-UIUV£RSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

packing, with ~

=

90° and

n

=

1, so that k~·c is given by:

(6.1)

where R1 can be obtained from Eq.

(5.3).

The effective thermal conductivity measurements obtained by Buonanno eta/.

(2003:251)

were determined by considering the total length of the experiment, that is

4ecJ

=

0.15[ m] .

Therefore, the total resistance of the experiment must be calculated. Owing to the structure of the packing, the thermal resistance of the bulk region can be obtained by the following:

R

L Lbulk

bulk

=

1\:ke

=

d!k:·c

(6.2)

where the length of the packed bed in the bulk region is 4ulk = (

0.15-

dP

)[m].

In the experimental setup, there are two wall regions. The thermal resistance between a hemisphere and a wall R1

,w

is shown in Eq.

(5.51),

and therefore the effective thermal conductivity for this experimental setup is:

kg,c _ Lbed

e,total -

d2

(R

)

p bulle +2R),W

(6.3)

where

4ecJ

=

0.15m.

Figure 6.1 displays the comparison between Eq.

(6.3)

and the data set developed by Buonanno eta/.

(2003:251).

It should be noted that Bahrami et a/.

{2006:3694)

suggest that an equivalent radius req

Eq.

{3.116)

be used between two spherical surfaces. However, Bahrami eta/.

{2006:3696)

also propose that req = rP between two spheres when they compared their model with Buonanno et a/.'s

{2003:251)

experimental data set. This, however, is in contrast to his theory, but he stated that it yielded better results.

Nonetheless, the Multi-sphere Unit Cell displays good agreement in Figure

6.1

with the experimental data at low surface roughness. However, it seems that it compares better when

req = rP at lower and higher surface roughness. The average percentage difference between the Multi-sphere Unit Cell Model and experimental data with req = rP is 2.96%.

MODELLING THE EFFECTIVE THERMAL CONDUCTIVIlY IN THE NEAR-WALL REGION

137

OF A PACKED PEBBLE BED

(4)

CHAPTER 6: VALIDATION AND VERIFICATION 0.50 . - - - , 52' 0.45 E

~

f

0.40 t; :::J "C s::

8

0.35 iii E

...

Q) £i 0.30 ~ t; ~ w 0.25

1 OOCrS Steel Spheres, SC Packing ~ Hmlc =8.32GPa, k8 E60W/mK Ep = 200GPa , f.l.p = 0.3 .EIYiQ; kg =0.027W/mK, Pr=D.7, rg =1.4 "'=0.78 F =0.983N

0 Experimental Data (Buonanno et al., 2003:693) <> Multi-sphere Unit Cell r_eq=r_p/2

-6.- Multi-sphere Unit Cell r_eq=r_p

0.20 +----...,---,,---r----.---.----...,---r---r----~ 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8

Surface roughness [J.Jm]

Figure 6.1: Comparison between Multi-sphere Unit Cell Model and Simple Cubic experimental data

(Buonanno eta/., 2003:251; constant force)

The second experimental data set developed by Buonanno et a/. (2003:251) that is

considered is that where the applied force was varied with a constant root mean. square surface roughness in the SC-packing arrangement. Comparison between Eq. (6.3) and experimental data is displayed in Figure 6.2.

It can be seen in Figure 6.2 that the Multi-sphere Unit Cell Model shows good comparison with the experimental data developed by Buonanno et a/. (2003:251 ), achieving an average percentage difference of 2.42% when (J'RMS

=

0.03 f.im and 5.62% when (J'RMS

=

1.7 f.im. It is shown that in both cases the Multi-sphere Unit Cell Model falls within the uncertainty bounds. The solid and gas properties used in the simulation results displayed in Figure 6.2 is exactly the same as those displayed in Figure 6.1.

Superimposed on to Figure 6.2, is the effective thermal conductivity obtained when using the Hertzian contact network defined in Eq. (5.4). The Hertzian contact network demonstrates the same trend as its counterparts. However, prediction overestimates the effective thermal conductivity to some extent. This is ascribed to the simplification of the surface roughness to a perfectly smooth contact surface. The rough contact network shows better agreement.

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

138

OF A PACKED PEBBLE BED

(5)

t~J·-·-WN

YUUIBESm YA BOKOflE-BOPHIRI/,0A

IIOORDWES-UJ JJVERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

0.70 , . - - - , 0.65 Sl E 0.60

~

.a-

0.55 ·;;: ~ 0.50 "C s::

8

0.45 "iii

e

o.4o Cll

.s

~ 0.35 :;::; 0

ffi

0.30 0.25 0.20

+---.---r---.---r---....,---1

0 Figure 6.2: 2 3 4 5 Force [N]

Comparison between Multi-sphere Unit Cell Model and Simple Cubic experimental data

(Buonanno eta/., 2003:251; constant surface roughness)

6

The third experimental data set of Buonanno eta/. (2003:251) that is considered is that of the FCC packing with a constant applied force ofF= 0.783N and varying the root mean square

surface roughness aRMS, as displayed in Table C.4. The effective thermal conductivity between two spheres in the FCC setup can be obtained by rewriting Eq. (5.34), in order to account for the FCC packing, with

"ic

= 45° and

n

= 4, as was displayed in Table 3.2, so that

kg

·

c

is given by: 4(d -(l) ) kg,c = P 0 sin{45°) e d2R. p J (6.4)

where Ri is given by Eq. (5.3). As previously mentioned, the effective thermal conductivity measurements obtained by Buonanno et a/. (2003:251) was determined by considering the

total length of the experiment and, therefore, the total resistance of the experiment must be calculated. However, in contrast to the SC packing, a different conduction area in a FCC-packing structure must be considered, which is displayed in Figure 6.3.

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

139

OF A PACKED PEBBLE BED

(6)

IIORTH·WESi UUI\I!ERSITY YUIII!lt'Sm YA BOKOUE-BOPHIRJMA

IIOOIIDWES-tJI M\IERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

Figure 6.3: Face-centred Cubic conduction area

The thermal resistance of the bulk region can then be calculated by the following:

(6.5)

where the length of the packed bed in the bulk region is Lbutk = {

0.15-

d P )[

m

J.

Again, the wall region must be taken into account with Ri,W as given by Eq.

(5.51).

The effective thermal conductivity for this experimental can therefore be calculated by:

kg,c _ Lbed e,total - 2 { 2R )

dp Rbulk

+

j,W

(6.6)

where Lbed =

0.15m .

Figure 6.4 displays the comparison between Eq. (6.6) and the data developed for the FCC packing by Buonanno eta/.

(2003:251).

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

140

OF A PACKED PEBBLE BED

(7)

0.8 52' 0.7 E

~

f

0.6

n

~ "C c

8

0.5 iii

e

Gl

=

0.4 ~

t;

~ w 0.3 0.2 0

~

~

~k

-1 OOCrtl Steel Spheres, SC Packing

~ Hm1a =8.32GPa, k8 ;8QW/mK Ep =200GPa, Jlp ;Q,3 .E!Yi!t k9 ;Q,027W/mK, Pr;0,7, r9 ;1.4 ar ;o.1a F ;Q,783N 0.2 0.4 0.6

CHAPTER 6: VALIDATION AND VERIFICATION

~

----~

~

'{:;

~

0 Experimental Data (Buonanno et al., 2003:693) o Multi-sphere Unit Cell r_eq=r_p/2

-t::.- Multi-sphere Unit Cell r_eq=r_p

0.8 1.2 1.4 1.6 1.8

Surface roughness [!Jm]

Figure 6.4: Comparison between Multi-sphere Unit Cell Model and Face-centred Cubic

experimental data

(Buonanno eta/., 2003:251; constant force)

The same comparison regarding the equivalent radius as done in Figure 6.1 is demonstrated for the FCC packing in Figure 6.4. Although both cases deviate from experimental data at the lower surface roughness regions, better comparison is obtained at higher surface roughness. It is therefore concluded in this study that req = rP for both the wall and bulk regions. The average percentage difference between the Multi-sphere Unit Cell Model and experimental data with req = rP is 8.9%.

The fourth experimental data set developed by Buonanno et a/. (2003:251) that is considered is that of varying the applied force with a constant root mean square surface roughness in a FCC-packing arrangement. The comparison between Eq. (6.6) and experimental data is displayed in Figure 6.5.

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

141

OF A PACKED PEBBLE BED

(8)

,,_.~

YUIIIBESm YA. BOKOtiE-BOPHIRit.IA

IIOORDWES-UllJVERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

0.9 S2' 0.8 E

~

b 0.7 ·:;:

:g

:l

-g

0.6 0 u iii

e

o.5 Q)

-s

~

:g

0.4

~

0.3 0.2 ~~~~~~~~~~~~~~~~~~~~

""l"

"

""""

"

"f""

f

~" ~~~~~ 00<><> 00000 ~~ o<>0<>0

~~~~

f

<><> <><><><><><><> a-5q = 0.03pm ~ ~ <> "<) <><>·<> <> <> 0 ' . o<><>o<>

~

2

.

P. o<><><> $

¢

J'o..A ~-<> <> <> <>

l

I J.: O"sq 1.7 pm

1

0 Experimental Data (Buonanno et al., 2003:693)

<> Multi-sphere Unit Cell ("'RMs = o.os,um)

~ Multi-sphere Unit Cell (Hertzian Contact Network)

o Experimental Data (Buonanno et al., 2003:693) -<>-Multi-sphere Unit CelllaRMs =1.7 .umi

0 0.5 1.5 2 2.5 3 3.5 4 4.5

Force [N]

Figure 6.5: Comparison between Multi-sphere Unit Cell Model and Face-centred Cubic

experimental data

(Buonanno eta/., 2003:251; constant surface roughness)

It can be seen in Figure 6.5 that the Multi-sphere Unit Cell Model shows relatively good comparison with the experimental data developed by Buonanno eta/. (2003:251), achieving

an average percentage difference of 8.85% when a-RMs = 0.03 .um and 4.08% for when

a-RMS = 1. 7 pm . The solid and gas properties used in the simulation results displayed in Figure 6.5 are exactly the same as that displayed in Figure 6.4.

It must be mentioned at this point that typical surface roughness of a graphite pebble after manufacturing or after passing through the reactor is not available and such data should be required for further simulations.

The next experimental data set that is considered is that developed using the HTO experimental test facility (Breitbach & Barthels, 1980:392; Rabold, 1982:156). The HTO experimental test facility consisted of a cylindrical graphite vessel containing the randomly

packed bed of spheres with diameter dP

=

0.04m. The cylindrical vessel had a diameter of

0.5m and a height of 0.7m (Section C.3). An induction-heating coil, situated outside the

cylindrical packed bed added heat to the bed. The effective thermal conductivity was

extracted using a transient method as explained in Breitbach & Barthels (1980:392). However, the use of a single porosity to characterise the whole packing can be questioned. Nonetheless, tests were conducted at vacuum and elevated pressures.

MODELLING THE EFFECTNE THERMAL CONDUCTIVIlY IN THE NEAR-WALL REGION

142

OF A PACKED PEBBLE BED

(9)

flj·-·~

YUUIBESI11 YllBOKOIIE-BOPHIRIMA

I IOORDWES-UJ UVERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

The first experimental setup that is considered is the test conducted at vacuum conditions with graphite spheres up to a temperature of almost 16oo•c. Due to the small size of the cylindrical packed bed, it is assumed as Breitbach & Barthels (1980:395) did, that the heat transfer only occurred through thermal radiation and that point contact conduction is negligible.

To validate this assumption, a parametrical study with the Multi-sphere Unit Cell Model is done at an elevated helium gas pressure (1atm-85kPa). Results shown in Figure 6.6

verifies that heat transfer mostly occurs through the bulk gaseous region rather than the point contact region as contact thermal resistance is much higher that gas thermal resistance. This indicates that at vacuum conditions heat will be transferred more easily by other methods such as thermal radiation rather than being transferred through point contact conduction. The material properties used in this parametrical study are the same as presented in Figure 6.8.

1000~---~

~

Cll 0 c 100

~

10

f!

iii

E

Cll ~ 0+---~----,---,---.---~----~----~----~----~ 0 200 400 600 800 1000 1200 1400 1600 1800 Temperature [ 'C]

Figure 6.6: Thermal resistance parametrical study in the bulk region

Comparing the radiation component of the Multi-sphere Unit Cell Model, Eq. (5.35), as well as the correlations proposed by Breitbach & Barthels (1980:392), Eq. (3.150), and Rabold

(1982:156), Eq. (3.165), with experimental data yield the results displayed in Figure 6.7. It should be noted that these aforementioned researchers (Breitbach & Barthels, 1980:392;

Rabold, 1982:156) also published different sets of experimental data obtained using the same test facility. However, these different experimental data sets deviate at temperatures above

12oo·c.

It is evident from Figure 6.7 that Rabold (1982:1) fitted his correlation presented in Eq. (3.164)

empirically to best represent his data. The correlation proposed by Breitbach & Barthels

MODELUNG THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

143

OF A PACKED PEBBLE BED

(10)

CHAPTER 6: VALIDATION AND VERIFICATION

(1980:392) is slightly higher than the experimental data at lower temperatures but has a tendency to increase with a lower rate at temperatures above 14oo•c.

The Multi-sphere Unit Cell (Radiation component) as shown in Figure 6.7 is calculated by the summation of the short and the long-range radiation components (bottom two lines). It was found that the Multi-sphere Unit Cell Model best represents the experimental data when

3.5 ~

ii

1ong ~ 4.7 in Eq. (5.50).

Nonetheless, the Multi-sphere Unit Cell Model demonstrates reasonable accuracy for temperatures below 1200°C but deviates at higher temperatures as shown in Figure 6.7. It is also interesting to note that the long-range radiation component shown in Figure 6.7 is slightly higher in magnitude than the short-range component, and has almost the same gradient (slope). However, this seems to be in contrast to Breitbach & Barthels (1980:392) who stated that in the Zehner & SchiOnder (1972: 1303) model, the effective thermal conductivity between touching spheres appears to be dominant at higher temperatures, meaning that short-range radiation should be larger at higher temperatures than long-range radiation.

25T.===o ~Exp==erim==ental Da~~~~~========~--~ta, Rabold (1982) --~---~~~

~

20

~

::-·:;:

:e

15 :I "C 1:

8

iii

e

10 Gl :;

-~

't) ~ 5 w 0

- - Breitbach & Barthels (1980)

-<>-Short-Range Radiation Component

6. Long-Range Radiation Component

D Experimental Data, Breithbach and Barthels (1980)

- -Rabold (1982)

- -Multi-Sphere Unit Cell (Radiation Component)

- -Multi-Sphere Unit Cell Radiation Com anent)

ks= 73.8428-ll.0898607T+5.57553E-05T2 -1.27420E-OBT3 [K],(W/mK) e, =0.505586+0.000792943T -5.22863E-ll7T2+1.1 0479E-1 OT3 [K] , • =0.39, dp = 0.04m , fk, Eq. (5.84) 200 400 600 800 1000 Temperature [ "C] nlong =4.7 1200 1400 1600

Figure 6.7: Comparison between Multi-sphere Unit Cell Model, Breitbach & Barthels and

Rabold correlations with experimental data of the High Temperature Oven with graphite spheres at vacuum conditions

(Breitbach & Barthels, 1980:395; Rabold, 1982:156)

For the Multi-sphere Unit Cell Model, certain assumptions were made that affects long-range radiation; the assumption that the average temperature across the effective long-range pebble

f

is the same as the average temperature over two spheres in contact, and that the non-isothermal correction factor fk is the same in long-range radiation as for short-range

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

144

OF A PACKED PEBBLE BED

(11)

CHAPTER 6: VALIDATION AND VERIFICATION

radiation. In reality is the average temperature

f

going to be higher between the long-range sphere and the sphere under consideration than the assumption previously made, resulting in

fk to decline more sharply at higher temperatures. Improvements can be made to the

Multi-sphere Unit Cell Model by deriving a non-isothermal correction factor specifically tailored for range radiation using CFD. Therefore, further investigation should be done into long-range radiation to accurately calculate this damping effect at temperatures above 1200°C.

It is also important to note that Figure 5.5 indicated that more spheres contribute to the long-range radiative thermal conductivity than indicated by the coordination flux number

'fitong = 4.7 ~ 5. However, these low values for iitong make sense here since the average long-range diffuse view factor

F.f:

2.avg is actually much higher than it would be for a properly

weighted value. Therefore, the long-range coordination flux number ii1ong simply

compensates for the earlier overestimation.

The second experimental setup of the HTO that is considered is the tests conducted at an elevated pressure Pg = 70kPa-85kPa, using helium as the saturated gas to a temperature of up to 927°C. A curve was fitted through the data by Rabold, 1982:160 and extrapolated to higher temperatures, as displayed in Figure 6.8. Again, Rabold's (1982:156) model was fitted empirically to best represent his experimental data.

S2' 25 E

~

~ 20 ~ ::s 'C c:

8

15 iii

e

Cll

.s

10 g! ~ ~ w 5 ks= 73.8428-0.089860n+5.57553E~5T2 -1.27420E-OBT3 [K],(W/mK) kt= 0.0557251+0.000357143T -4.87013E~BT2 (K],(W/mK)(He/ium) e,=0.505586+0.000792943T-5.22863E-On2+1.1 0479E-1 OT3 [K] , F =0.2N, s = 0.0085 , e = 0.39, dp = 0.04m , fk, Eq. (5.84) , Ep = 7.41GPa , J.lp = 0.3 o Experimental Data, Rabold (1982)

- -Multi-Sphere Unit Cell Radiation Component - - IAEA ZS Radiation Component

- o -Multi-Sphere Unit Cell Conduction Component --0--IAEA ZS Conduction Component

- o -Multi-Sphere Unit Cell Total

l:J. IAEA ZS Total - -Rabold (1982) Total 0+---~---~---.---~---~----~~---.---~ 0 200 Figure 6.8: 400 600 BOO 1000 1200 1400 1600 Temperature [

·q

Comparison between Multi-sphere Unit Cell Model and the proposed International Atomic Energy Agency correlation with experimental data of

the High Temperature Oven, ('iitong = 4.7)

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

145

OF A PACKED PEBBLE BED

(12)

llORTH-WESi UW\IERSITY

YUNIBE5m YA BOKotiE • BOPHIR.WA

llOORDW£S.UIIIvt'RSITErT CHAPTER 6: VALIDATION AND VERIFICATION

The correlation proposed by the Niessen & Ball (2000:301) is also included in Figure 6.8, indicated by IAEA ZS Total representing the summation of Eq. (3.20), Eq. (3.102) and Eq. (3.150), where as the Multi-sphere Unit Cell Total represents the summation of the conduction component Eq. (5.34) and the radiation component Eq. (5.35) using the Hertzian contact

network. Rabold's results were calculated with Eq. (3.163). Furthermore, a small contact

force between the pebbles was assumed due to the packed bed being so small in geometry.

It is interesting to note that both the Multi-sphere Unit Cell Model (Hertzian contact network) and the IAEA ZS Total correlation are higher than the experimental data and intuitively the correlation proposed by Rabold (1982:129). One possible reason worth investigating may be

the method Rabold (1982:129) used to extract the effective thermal conductivity data from

experimental results. The Multi-sphere Unit Cell Model and the IAEA ZS Total correlations

are in good agreement with each other up to a temperature of 1200°C and thereafter deviate. This can be attributed as previously mentioned to the non-isothermal correction factor for long-range radiation, which is assumed to be the same as for short-range radiation.

6.3

VALIDATION OF MULTI-SPHERE UNIT CELL MODEL IN

THE WALL REGION

In this section, the conduction and radiation components of the Multi-sphere Unit Cell Model in the wall region are validated separately and integrally, using data obtained by Kitscha &

Yovanovich (1974:93) and Rabold (1982:160).

Kitscha & Yovanovich (1974:93) conducted experiments on the overall thermal joint

resistances between a steel sphere and a flat surface as presented in Figure C.1. The load was varied to study the effect on overall solid and gas conduction. For each constant load,

the gas pressure was also varied from vacuum to atmospheric conditions.

For this study, the experimental test conducted with argon as the interstitial gas was considered. Comparison between experimental results and Eq. (5.68) of the Multi-sphere Unit Cell Model is displayed in Figure 6.9. It should be noted that Kitscha & Yovanovich

(1974:93) did not give a root mean square surface slope value, mRMS, so the general

correlation of Tanner & Fahoum (1976:299), displayed in Table 3.4, was used to determine

mRMs as it gave the best results.

It can be seen that the Multi-sphere Unit Cell Model compares quite well with the experimental results of Kitscha & Yovanovich (1974:93), at higher applied loads. A deviation

from the experimental results at an applied load ofF= 16N however is observed. This can

be attributed to the fact that the correct root mean squared surface slope, mRMS , is not known

MODELLING THE EFFECTIVE THERMAL CONDUCTIVIlY IN THE NEAR-WALL REGION

146

OF A PACKED PEBBLE BED

(13)

CHAPTER 6: VALIDATION AND VERIFICATION

as it effect results more at lower applied forces. In addition, it can also be seen that the thermal resistance at F

=

16N follows a trend different from its counterparts, at higher applied loads. The highest average percentage difference between the Multi-sphere Unit Cell Model and experimental data, disregarding the F = 16N case, is 9.15%.

80 ,---~====~======~ o 16 N (Experimental) 70 60

~50

Cll u s:::: .l!l 40 .!!!

~

c

30 ·c; ...., 20 10

Carbon Spheres, Wall Region

Solid: Hm1c =4GPa, k8 =16.76W/mK, Ep =4.35GPa, l'p =0.3, CT8q =0.13pm .E!l!if!: kg =0.0173126 W/mK, Pr=0.67, r 9 =1.67, ar =0.90 Ao =66.6xto·9m 0 55.6 N (Experimental) A 195.7 N (Experimental) e 467 N (Experimental) -i!r-16N (Calculated) -<>-55.6 (Calculated) -D-195.7 N (Calculated) -¢-467 N (Calculated) 0 ~~~~~~~~~~~~~~~~~~~~~~~~~~--~~~ 0.001 Figure 6.9: 0.01 0.1 10 100

Gas pressure [kPa]

Comparison between Multi-sphere Unit Cell Model and Kitscha & Yovanovich experimental data for the wall region

(Kitscha & Yovanovich, 1974:93)

The next test that is considered is that conducted by Rabold (1982:160) for heat transfer in the wall region at vacuum and elevated pressure (helium) conditions. Comparison of the experimental data with the Multi-sphere Unit Cell Model, Eq. (5.74) and Eq. (5.81), at vacuum conditions leads to Figure 6.1 0.

Comparison between the experimental data and the Multi-sphere Unit Cell Model in the wall region shows good agreement. It was found that ~~g = 1 , with the sphere and wall emissivity assumed to be the same. It is also interesting to note that the long-range radiation in the wall region is much lower than in the bulk region, which is also used for calculations in the near-wall region as previously stated. This confirms that thermal radiation heat transfer in the wall region occurs mainly between the wall and spheres in contact.

Comparison of the experimental data with the Multi-sphere Unit Cell Model, Eq. (5.68), Eq. (5.74) and Eq. (5.81), at elevated pressure conditions (helium) in the wall region led to Figure 6.11. Again, as demonstrated in Figure 6.8, the prediction of the Multi-sphere Unit Cell is higher than the experimental data obtained by Rabold (1982:160). As previously mentioned one possible reason worth investigating may be to analyze the method

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

14 7

OF A PACKED PEBBLE BED

(14)

CHAPTER 6: VALIDATION AND VERIFICATION

Rabold (1982:129) used to extract the effective thermal conductivity data from experimental results. 4.---~ 3.5 52' E ~ 3 l:' ·:;: ~ 2.5 "CC c:

8

2

~

Q) 1.5 ..c:

-~

:!l

w 0.5 ks= 73.8428-0.0898607T+5.57563E-05T2 -1.27420E-OST3 [K],(W/mK) e,=0.505586+0.000792943T-5.22863E-07T2 +1.1 0479E-1 OT3 [K] ,

dp = 0.04m , fk, Eq. (5.84)

0 Experimental Data, Rabold (1962) - Multi-Sphere Unit Cell

-<>-Short-Range Radiation Component

-0+---.---.---~---.---.---.---~

300 350 400 450 500

Temperature [ 'C]

550 600 650

Figure 6.10: Comparison between Multi-sphere Unit Cell Model and experimental data in the wall region at vacuum conditions

8 7

52'

E ~6

f

11

5 :I

-g

8

4

~

Q) 3 ..c:

-

~

11

2

ffi

(Rabold, 1982:160) ks= 73.8428-0.0898607T +5.57553E-05T2 -1.27420E-OST3 [K],(W/mK)

kf= 0.0557251 +0.000357143T -4.B7013E-OST2 [K], (WI mK)( Helium)

s,=0.505586+0.000792943T-5.22863E-07T2 +1.1 0479E-1 OT3 [K] ,

F=0.2N, dp =0.04m, fk,Eq.(5.84), Ep =7.41GPa, Pp =0.3

o Experimental Data, Rabold (1962) - Multi-Sphere Unit Cell Radiation

-<>-Short-Range Radiation Component

!::. Long-Range Radiation Component Multi-Sphere Unit Cell Conduction

-0-Multi-Sphere Unit Cell Total

--300 350 400 450 500 550 600 650 700 750

Temperature [ "C]

Figure 6.11: Comparison between Multi-sphere Unit Cell Model and experimental data in the wall region at elevated pressure saturated with Helium

(Rabold, 1982:160)

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

148

OF A PACKED PEBBLE BED

(15)

IIORTH·WEST UlllV£RSITY YUUI!Il:SlTI YA llOKOHE-BOPH!RlMA

IIOOROWES-UIIM!RSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

6.4

VERIFICATION OF THE MUL TI-S PH ERE UNIT CELL

MODEL IN A RANDOMLY PACKED BED

The SANA-I experimental test facility was chosen to compare the experimental effective thermal conductivity results with those predicted by the Multi-sphere Unit Cell Model in a randomly packed bed configuration considering all the integrated effects. The test facility investigated the heat transfer mechanisms inside the core of a pebble bed HTR. A limitation of this experimental data set is that the tests were conducted at a pressure near atmospheric conditions. This results in natural convection flows to occur increasing the effective thermal conductivity, as shown graphically in Appendix C (Figure C.4).

The SANA-I experimental test facility had a central heater element with a diameter of 0.13 m and an outer cylindrical diameter of 1.5 m. Two different sized graphite pebble diameters were used namely dP = 60mm and dP = 30mm, in a randomly packed arrangement with a bed height of Lbed = 1 m. The bed was heated by an electrical resistance graphite heater, as shown in Figure C.4, for which temperature profiles were generated at three different heights.

For this study, the 1 0 kW and 35 kW long heater element with the pebble diameter of

dP = 60mm, saturated with helium is considered. Test results were obtained from Stocker (1998:34) and are presented in Table C.10 and Table C.11. The isothermal temperature distribution for the 35 kW long heater steady-state is presented in Figure C.5.

The effective thermal conductivity for the SANA-I experimental test facility was previously extracted as a function of temperature only as shown in Niessen & Ball (2000:306). This approach, however, is not suitable to observe any effects that the porous structure may have on the effective thermal conductivity in the radial direction. Therefore, it was decided that the following approach would be used to extract the effective thermal conductivities for the two aforementioned steady-states:

(6.7)

It should be noted that the more refined approach that was used to extract of the effective thermal conductivity from the HTTU data, Eq. (4.2), could not be applied to the SANA results because there are only eight radial temperature measurements. As Dieck (2007:174) explains, the number of polynomial curve-fit constants must be far less than the number of experimental measurements in any polynomial curve fit and that was not the case for the SANA-I experimental results. Furthermore, it was also decided to extract only the effective thermal conductivity for the temperature profiles measured at heights 0.5 m and 0.91 m. This eliminates any influence the bottom electrode coolers may have on the temperature profiles.

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

149

OF A PACKED PEBBLE BED

(16)

'

,.,.,._

VUIIIBESm YA.. BOKOfiE-BOPHIRIMA

.

.,,

..

""""'

IIOORDWES-UIIIVERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

The heat flux

PHea

6ng Element , tabulated in Table C.1 0 and Table C.12, was used as a constant

throughout the packed bed in the radial direction and therefore adiabatic top and bottom boundaries were assumed. This is a valid assumption because Van Antwerpen (2007:121) stated that from sensitivity studies it was found that modelling the top and bottom insulation had a negligible effect on the temperature results. The effective thermal conductivity results are tabulated in Table C.12 and Table C.13 and presented graphically in Figure C.6 and Figure C.?.

Comparison between the Multi-sphere Unit Cell Model and other correlations are compared with the SANA-I experimental results obtained from Niessen & Ball (2000:306) as a function of temperature, is shown in Figure 6.12. The coordination flux number for the long-range radiation was taken as

n

1ong = 4. 7. This is also done for all the analyses presented in the remainder of this chapter. The contact force distribution was taken to be the same as that of the HTTU (Eq. 0.49) due to the close geometrical proximity of the pebbles and packed bed.

When comparing the effective thermal conductivity simulation results with the experimental data given in Figure 6.12, it must be remembered that heat is transported not only by thermal conduction and radiation, but also by natural convection in the pebble bed. Natural convection in the SANA-I experimental test facility was not suppressed as the developers of the test facility wanted to measure how natural convection assists in the decay heat removal process. This explains why the majority of the correlations presented in Figure 6.12 are somewhat lower than the measured values (Niessen & Ball, 2000:302).

28,---.---,

26

Graphite Spheres, Randomly Packed

ks= 166.021-39.5408E-02T+4.8852E-04T2 -2.91E-07T3 + 6.6E-11T4 ICJ.(W/mK)

kg=0.0557251+0.000357143T-4.87013E-08T' [K], (W/mK)[Helium) , dp = 0.06m

F = 72.307 · Zdepfh + 7.8716 (N) , Zdepth = O.Sm , s = 0.0085 , cr = 0.8 , e = 0.385 ,

,Ep=7.41GPa, Pp=0.3, {0=0.01, Pg=1atm=85kPa

0 ~ 24

.€

22

~

20 ~ r---~ > 18 t;

.g

16 c

8

14 iii E

...

12 C1) 10 ..c t-~ 8 :;:; CJ 6

~

4 2 0 0 100 200 _ , _Rabold (1982) Total 300 400 500 600 700 BOO 900 1000 Temperature ['C)

Figure 6.12: Comparison between various correlations and SANA-I experimental data versus temperature saturated with helium.

(Niessen & Ball, 2000:306)

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WAU REGION

150

OF A PACKED PEBBLE BED

(17)

~

·-wm•~­

vummm Yll BOKOI IE-BOPHIRIM.I

l IOORDWES-UJ UVERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

Figure 6.12 demonstrates that the IAEA ZS Total, the ZBS presented in Eq. (3.89), and the Multi-sphere Unit Cell Model are in close agreement with each other. The ZBS correlation deviates slightly due to the contact area fraction parameter rp being unknown for the packing. However, the model proposed by Kunii & Smith (1960:71 ), Eq. (3.130), somewhat over-predicts the effective thermal conductivity, while the correlation proposed by Rabold (1982: 156) under-predicts the values.

In Figure 6. 13, the two different components of the Multi-sphere Unit Cell Model are demonstrated. It should be noted that the contribution of thermal radiation is only the dominant factor at temperatures above

soooc

for a packed bed saturated with helium gas. This emphasises that the effective thermal conductivity due to conduction

k:·c

should not be discarded in any effective thermal conductivity analysis and that the accurate simulation thereof is important, especially at lower temperature.

It is evident from Figure 6.13 that the effect the near-wall and wall regions have on the effective thermal conductivity measurements can not be clearly distinguished. Therefore, the effective thermal conductivity measurements were extracted in the radial direction as previously mentioned and the comparative results for the 1 0 kW steady-state are displayed in Figure 6.14.

2 6 r - - - . - - - .

Graphite Spheres, Randomly Packed

24 ks= 166.021-39.540BE-02T+4.8852E-ll4T2 ·2.91E-llrr3 + B.6E-11r4 [q,(W/mK) Pg =1alm=B5kPa !;2' 22 kg=0.0557251+0.000357143T-4.87013E-ll8P [KJ, {W/mK)<Hellum), Zdepth =0.5m, Pp =0.3

E F=72.307-Zdepfh+7.8716(N), er=0.8, e=0.385, dp=0.06m ,Ep=7.41GPa

~20 ~---

~

18 o Experimental Data, IAEA-Tecdoc-1163 (2000) o 0

v

;..!:!~ 16 -Lr-Multi-Sphere Unit Cell Total

0 / , / '

_ - -Multi-Sphere Unit Cell, Radiation Component

"C 0 Multi-Sphere Unit Cell, Conduction Com onent o0

§M ~ ~ 12 0 0 0 ~tr ~ 0 0 t9 ,trlr Q) 10

8

°

?:J

lr~

£ 0 0 0 0 0 trlrlr (()8 0 ~~~ ~ c:/&fr6-A~f'rls. u 6 A-A-{:s-tl-f'r. ~ 00000~000000000000000~ w 4 2 0+---.---.---.---.---.---.---.---.---.---4 0 100 200 300 400 500 600 700 800 900 1000 Temperature ['C)

Figure 6.13: Compari-son between the Multi-sphere Unit Cell Model components and

SANA-I effective thermal conductivity experiment, experimental results (Niessen & Ball, 2000:306)

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

151

OF A PACKED PEBBLE BED

(18)

UORTH·WEST Ullll/£l!SJTY YUJUBESm VABOKOilE·BOPHIRU,\A

JIOORDWES-UJ JJVERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

1 6 . - - - . 14 !Z E ~ 12 ~ >

..

u 10 :::1 "C s:: 0 8 0 iii E

...

6 Ill ..c: 1-~

..

u 4 ~ w 2 0 0 <>

Graphite Spheres, Randomly Packed

- o-Experimental Data H

=

0.91 m - o -Experimental Data H

=

0.5 m - L>-Multi-Sphere Unit Cell Total H

=

0.91 m

<> IAEA ZS Total H = 0.91 m

-·-·-·Multi-Sphere Unit Cell Total H

=

0.5 m

--IAEA ZS Total H = 0.5 m

ks= 186.021-39.540BE-02T+4.8852E-04T2 -2.91E-07T3 + 6.6E-11T4 [CJ,(WfmK) , Pg =1alm=85kPa

t<g=0.0557251+0.000357143T -4.87013E·OBT' [K], (W/mK)(Helium) , Zdepth = 0.09m and o.sm , l'p = 0.3

F =72.307-ZcJepth + 7.B716(N) , sr =0.8, s=s•, Eq.(2.30), dp =0.06m, Ep = 7.41GPa , fk,Eq. (5.84)

2 3 4 5 6 7 8 9 10 11

Sphere Diameters From Inner Wall

12

Figure 6.14: Comparison between effective thermal conductivity correlations and

experimental results of the SANA-I experimental test facility for the 1 0 kW steady-state 28. -- -- - - -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- - - -- - - -- - - -- -- -- . 26 !Z 24 ,E 22

~

20 ~ > 18

..

u :::1 "C 16 s:: 0 14 0 iii 12 E

...

Ill 10 ..c: 1-~ 8

..

u 6 ~ w 4 2 0 0 <>

Graphite Spheres, Randomly Packed

--o-Experimental Data H - 0.91 m -a--Experimental Data H = 0.5 m

~Multi-Sphere Unit Cell Total H

=

0.91 m <> IAEA ZS Total H

=

0.91 m

---Multi-Sphere Unit Cell Total H

=

0.5 m

- - IAEA ZS Total H

=

0.5 m

ks= 186.021-39.540BE-02T+4.8852E-04T2 -2.91E.07T3 + 6.6E-11T4 [C],(W/mK) , fk,Eq.(S.B4)

kg=0.0557251+0.000357143T -4.87013E-OBT' [KJ, (WfmK)tHelium) , Zdepth = 0.09m and O.Sm F =72.307-Zdepth +7.8716 (N) , cr =0.6, s=s•, Eq.(2.30) , dp =0.06m, Ep =7.41GPa, l'p =0.3

2 3 4 5 6 7 8 9 10 11

Sphere Diameters From Inner Wall

12

Figure 6.15: Comparison between effective thermal conductivity correlations and

experimental results of the SANA-I experimental test facility for the 35 kW steady-state

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

152

OF A PACKED PEBBLE BED

(19)

fij·-··~

YUIIIBESm YABOKOtiE-BOPHIRIMA

, -'\ UOOROWES-Ul lllfERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

In Figure 6.14, the effect of natural convection can be seen more profoundly with the effective thermal conductivity peaks at 3.5dP and 9.5dP sphere diameters from the inner wall. It is also demonstrated that the IAEA ZS Total correlation fails in the near-wall region where the Multi-sphere Unit Cell Model captures the expected decrease in effective thermal conductivity in the near-wall region. However, the effective thermal conductivity right next to the inner wall shows a slight increase from that slightly away from the wall. The comparative results for the 35 kW steady-state test can be seen in Figure 6.15.

It can be seen in Figure 6.15 that the IAEA ZS Total correlation again breaks down in the wall region. It is interesting to note that from the study in Figure 6.16 a slight increase in effective thermal conductivity (conduction) of the Multi-sphere Unit Cell Model at the inner wall is evident, where thermal radiation decreases. This phenomenon is also evident in the conduction component of the Multi-sphere Unit Cell Model in the 1 0 kW steady-state case (not shown).

28r---~==~;===~;=~~==~ 0 ~-Experimental Data H = 0.91 m

26 - !J.- Multi-Sphere Unit Cell Total

S2' 24 .§22

~

20 ~ ~ 18

-6

16 c

8

14

~

12

1!

10

-

~ 8 ~ ~ 6 w 4 2

- -Multi-Sphere Unit Cell Radiation

- Mulit-Sphere unit Cell Conduction o IAEA ZS Total

- - IAEA zs Radiation --D-IAEA ZS Conduction

0+----.----~---~---~---~----.---~----.---~

0 2 3 4 5 6 7 8 9 10 11 12

Sphere diameter from inner wall

Figure 6.16: Comparison between effective thermal conductivity correlations (components) and experimental results of the SANA-I experimental test

facility for the 35 kW steady-state

There are two important issues that must be raised for the simulation of the effective thermal conductivity at the "inner reflector" of the SANA-I experimental test facility.

Firstly, it must be mentioned that thermal radiation was found from analysis to be the dominant heat transfer mechanism in both of the aforementioned cases at the "inner reflector". The Multi-sphere Unit Cell Model (radiation component) for the wall region, Eq. (5.81 ), was developed based on an almost flat wall surface. In general, the packing in the

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

153

OF A PACKED PEBBLE BED

(20)

! lORTH·WEST UU!\IEI!.SfTY YUlllBES!TI YA BOKONE.BOPHIRJMA

IIOOI'IDWES·UillV£RSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

inner wall region for the SANA-I experimental facility is different from that of a flat surface since the "inner reflector" actually consisted of a single heater electrode with a severe curvature, as illustrated in the exact scaled representation in Figure 6.17. This would entail a much lower diffuse view factor between the "inner reflector'' and the sphere in contact, resulting in a much lower contribution to the effective thermal conductivity by thermal radiation. This phenomenon will result in the summation of the radiation and conduction component to be much lower.

Central Graphite Heater

Graphite Pebbles

Figure 6.17: Packing structure in the inner region of the SANA-I experimental test facility

Secondly, it is noted that an increase in the conduction component of the Multi-sphere Unit Cell Model exist at the "inner reflector". This make sense due to the fact that conduction mostly occurs through the bulk gaseous region as displayed in Figure 6.6 with the low

Rc;

thermal resistance. The increase in the conduction effective thermal conductivity occurs due to the porosity increasing to one, which intuitively means more gas to conduct through. This increase will not be as profound if nitrogen was used as the gas medium due to a much lower gas thermal conductivity. That said, the effective thermal conductivity prediction in the outer wall region compares better with the measurements of Figure 6.14 and Figure 6.15.

The last comparison between the effective thermal conductivity correlations and experimental results is done by considering the HTTU. Comparative results for Tests 1 and 2 for the 20 kW state are displayed in Figure 6. 18 and Figure 6.19, and results for the 82.7 kW steady-state are displayed in Figure 6.20 and Figure 6.21.

It should be noted that no decrease of effective thermal conductivity in the near-wall region is visible in the experimental results for the extraction of the effective thermal conductivity measurements in level C (Figure 6.18, Figure 6.19). Therefore, the effective thermal conductivity was also extracted for thermocouples on level D for the first test done at the 20 kW steady-state as shown in Figure 6.18. This however can only be done for the first 20 kW steady-state test, due to the thermocouples being out of order thereafter. Nonetheless, the effective thermal conductivity values on level D show that there is a declination in effective thermal conductivity on the 20 kW steady-state as well.

MODELLING THE EFFECTIVE THERMAL CONDUCTIVIlY IN THE NEAR-WALL REGION

154

OF A PACKED PEBBLE BED

(21)

liORTH·WEST Ulll\ID!SITY YUJUBESlTl YA.BOKOliE-BOPHfRJ,'.IA

JIOORDWES-UJIJVER5JTEIT CHAPTER 6: VALIDATION AND VERIFICATION

11 .---, 10

2'

9 E

~

8

f

7 ~ ::I , 6

8

iii 5

E

Gl 4 £ ~ 3 ~

~

2 w

k6= 147.096-0.229541T+2.06027E-04T2 -7.1529E-OBT3 [C],(WimK),

kg =-4.3623E·05+ 1.02003E-04T-5.9415BE-OBT2 +2.2227BE-11T3 [K]. (WI mK)(Nitrogen) ,

F=72.307·Zdepth+7.B716(N), Zdepth=0.6m S=0.0085 ,<r=O.B, e=?,Eq.(2.30),

dp = o.oom , Ep = 7.41GPa , Pp = 0.3 , rk. Eq. (5.84)

T=951.31 9-21 09.784r+3734.120r2 -4765.290r3 +3144.4B9r4 -82B.346r5 [m], ("C)

-o-Level C Test 1 HTTU

-6-Multi-Sphere Unit Cell Total

-¢-IAEA ZS Total

-o-Rabold (1982) Total --¢-Level 0 Test 1 HTTU

0~~==~==~==~~--~--~--~~--~--~--~~--~~

0 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Sphere diameter from inner wall

Figure 6.18: Comparison between effective thermal conductivity correlations and experimental results of the High Temperature Test Unit experimental test

facility for the 20 kW steady-state, Test 1

2'

E

~

l:' ·:; ~ ::I

,

1: 0 1.1 iii

E

Gl .1:

-

~ ':;::; u ~ w 11 10 9 8 7 6 5 4 3 2

\

\

k5= 147.096-0.229541T+2.06027E-04T 2 ·7.1529E-OBT3 [C],(WimK),

kg =-4.3623E-05+1.02003E-04T-5.94158E-08T2 +2.22278E-11 T3 [K], (WI mK)(Nitrogen) ,

F=72.307·Zdepth +7.B716(N), Zdepth =0.6m S=0.0085, •r =0.8, s=?,Eq.(2.30),

dp = 0.06m , Ep = 7.41GPa , Pp = 0.3 , fk, Eq. (5.84)

T=1089.172-3328.523r+ 7982.622r2 -11573.499r3 +8286. 750r4 -2320.020r5 [m], ("C)

-o Level C Test 2 HTTU

-o-Multi-Sphere Unit Cell Total

~ IAEA ZS Total -o-Rabold (1982) Total

0+----.---.----.----.---.----r---.----.--~r---.----.--~r---.----.--~

0 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Sphere diameter from inner wall

Figure 6.19: Comparison between effective thermal conductivity correlations and experimental results of the High Temperature Test Unit experimental test

facility for the 20 kW steady-state, Test 2

MODELLING THE EFFECTIVE THERMAL CONDUCTMTY IN THE NEAR-WALL REGION

155

OF A PACKED PEBBLE BED

(22)

IIOitTH-WEST 0111\/EI!.SITY \1JUI!JfSl11 YA BOKONE·BOPHIRL\'.A

IIOOIWWI:S-UU!VfRSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

From Figure

6.18

and Figure

6.19

it can be seen as in the case for the SANA-I experimental test facility, that the IAEA ZS Total correlation breaks down when entering the near-wall region. It is interesting to note that in the region of 2dP and

11

.

8dP

the effective thermal conductivity of the IAEA ZS Total correlation changes rapidly (also seen in Figure

6.14

and Figure

6.15).

This is due to the contact area conduction parameter

k;,

Eq.

(3.1 02),

not being a continuous function with varying porosity that lead to a rapid increase when porosity fell into FCC range changing the parameters displayed in Table

3.2

and Table

3.3.

In contrast, the Multi-sphere Unit Cell Model demonstrates a decrease in effective thermal conductivity when entering the near-wall region. It is unclear why the Multi-sphere Unit Cell Model under-predicts the experimental effective thermal conductivity in the near-wall and wall regions. However, one possible cause, worth investigating, is that the test was conducted at

10

kPa and not total vacuum. Although the system pressure is very low, natural convection cannot be disregarded entirely. Therefore, a further investigation should be done to analyzing the effect of natural convection in the HTTU. Another cause worth investigating is the impact

k, eff has on the experimental effective thermal conductivity. The correlation proposed by Rabold

(1982

:

156)

again under-predicts the effective thermal conductivity results.

Comparison between the Multi-sphere Unit Cell Model and the IAEA ZS Total correlation with the

82.7

kW steady-state test cases shows good comparison with the experimental data, displayed in Figure

6.20

and Figure

6.21.

Again, it can be seen that for both test cases the simulated effective thermal conductivity results in the near-wall and wall regions obtained with the Multi-sphere Unit Cell Model is slightly lower than that determined experimentally and that the correlation proposed by Rabold

(1982:156)

under-predicts the effective thermal conductivity. A breakdown of the different components for the Multi-sphere Unit Cell Model and the IAEA ZS Total correlations is shown in Figure

6.22.

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

156

OF A PACKED PEBBLE BED

(23)

IIORffi-WEST UIIIVEI!SITY VUUIBESm Y/t BOKOIIE-BOPHIRU.\A

IIOOROWES-UJJJVERSITEIT CHAPTER 6: VALIDATION AND VERIFICATION

30,---~---~----~---~

k1= 147.096-0.229541T+2.06027E-04T2 -7.1529E-{)8T3 [CJ,(W/mK)

k9 =-4.3623E-{)5+1.02003E-04T -5.94158E-{)ST2+2.2227SE-11T3 [K], (W/mK)(Nttrogen) , ~ 25

E

F = 72.307 ·Zciepth + 7.8716 (N) , ZcJepth = 0.6m s = 0.0085 , "r = 0.8 , B =e•, Eq.(2.30) , dp = 0.06m , Ep = 7.41GPa , l'p = 0.3 , fk, Eq. (5.84)

T=4997.445-37661. 052r+ 155180. 029r2 -349683. 753r3 +456475. 830r4

~

__

...

0 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Sphere diameter from inner wall

Figure 6.20: Comparison between effective thermal conductivity correlations and experimental results of the High Temperature Test Unit experimental test

facility for the 82.7 kW steady-state, Test 1

30~---r=============================================--~ k8= 147.096-0.229541T+2.06027E-04T2 -7.1529E-{)BT3 [C],(W/mK)

k9 =-4.3823E-{)5+1.02003E-04T-5.9415BE-08T2+2.22278E-11T3 [K], (W/mK)(Nltrogen) ,

F =72.307·Zdepth +7.8716 (N) , Zdepfh =0.6m s=0.0085 , er =0.8, e =e*, Eq.(2.30),

dp = 0.06m , Ep = 7.41GPa , Pp = 0.3 , fk, Eq. (5.84)

T=4997.445-37661.052r+ 155180. 029r2 -349683. 753r3 +456475.830r4 -347878.927r5 +144647.673r6 -25652.29?r7 [m], ("C)

o Level C Test 2 HTTU

~Multi-Sphere Unit Cell Total

~ IAEA ZS Total -D-Robold (1982) Total O+---,----.---.---.~--r---,----.---.---..---r---,----.---.----.---4 0 2 Figure 6.21: 3 4 5 6 7 8 9 10 11 12 13 14 15

Sphere diameter from inner wall

Comparison between effective thermal conductivity correlations and experimental results of the High Temperature Test Unit experimental test

facility for the 82.7 kW steady-state, Test 2

MODELLING THE EFFECTIVE THERMAL CONDUCTIVITY IN THE NEAR-WALL REGION

157

OF A PACKED PEBBLE BED

(24)

CHAPTER 6: VALIDATION AND VERIFICATION

25r---.

-o- Level C Test 1 HTIU

-t:r-Multi-Sphere Unit Cell Total

- -Multi-Sphere Unit Cell Radiation -4--Multi-Sphere Unit Cell Conduction

IAEA ZS Total - - IAEA ZS Radiation

- D-IAEA .ZS Conduction

0+---~--~--~--~--~--.---.---~---.---.---.---.---.---.--_,

0 2

Figure 6.22:

3 4 5 6 7 8 9 10 11 12 13 14 15

Sphere diameter from inner wall

Comparison between effective thermal conductivity correlations (components) and experimental results of the High Temperature Test

Unit experimental test facility for the 82.7 kW steady-state, Test 1

6.5

CONCLUSION

This chapter presented the verification and validation of the separate components of the Multi-sphere Unit Cell Model as well as the integrated model by comparing predicted results with that of various experiments. Good comparison between experimental data and the

conduction component of the Multi-sphere Unit Cell Model was achieved. In addition, the

radiation component of the Multi-sphere Unit Cell Model for temperatures below 1200°C appears to be promising. However, some uncertainty still arises for temperatures above 1200°C. This uncertainty can be attributed to several assumptions that were made: the non-isothermal correction factor is assumed to be the same as that of short-range radiation, the average temperature between the long-range pebble and the pebble under consideration is assumed to be the same as that of two adjacent spheres and the long-range diffuse radiation view factor used is only an average, unweighted view factor. Also caution should be taken when simulating effective thermal conductivity for lower solid material thermal conductivity values. This is because the non-isothermal correction factor is only valid for a specific range of

1j

As . Improvements were proposed to the Multi-sphere Unit Cell Model to increase the applicability above 1200°C and for lower solid conductivity materials; deriving a non-isothermal correction factor specifically tailored for long-range radiation and extending the range of 1/ A5 • Both can be done with CFD.

MODELLING THE EFFECTIVE THERMAL CONDUCTIVIlY IN THE NEAR-WALL REGION

158

OF A PACKED PEBBLE BED

Referenties

GERELATEERDE DOCUMENTEN

probably a later development in the growth of the epic, when the image of Troy itself had already become more or less fixed. But also the idea that this wall was a work of hybris

viridifaciens alpha strain on LPMA medium yields green, mucoid colonies exclusively consisting of L-form cells, unlike the wild-type strain that forms yellowish colonies consisting

the fluid velocity field, to any desired order in the two parameters a/R and In paper I the mobilities in an unbounded fluid were evaluated explicitly up to and including terms of

The collagen composition in the aneurysm wall of men and women are in several aspects similar, with the excep- tion of collagen cross-linking, suggesting that the differ- ence

Figure 6.19: Comparison between effective thermal conductivity correlations and experimental results of the High Temperature Test Unit experimental test facility for the 20

Chapter 5 demonstrates the development of the Multi-sphere Unit Cell Model capable of simulating the effective thermal conductivity in the bulk region and wall region

The focus of this chapter is the development of a new model for the effective conductivity that includes the following seven heat transfer mechanisms: (1) conduction through

demonstrated breakdown in the near-wall and wall regions where the Multi-sphere Unit Cell Model slightly under-predicted the experimental effective thermal