Direct sample introduction of high boiling compounds onto

glass capillary columns. Comparison of manual and automatic

sampling

Citation for published version (APA):

Cramers, C. A. M. G., & Vermeer, E. A. (1975). Direct sample introduction of high boiling compounds onto glass capillary columns. Comparison of manual and automatic sampling. Chromatographia, 8(9), 479-481.

https://doi.org/10.1007/BF02267587

DOI:

10.1007/BF02267587

Document status and date: Published: 01/01/1975

Document Version:

Publisher’s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Please check the document version of this publication:

• A submitted manuscript is the version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website.

• The final author version and the galley proof are versions of the publication after peer review.

• The final published version features the final layout of the paper including the volume, issue and page numbers.

Link to publication

General rights

Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.

• Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain

• You may freely distribute the URL identifying the publication in the public portal.

If the publication is distributed under the terms of Article 25fa of the Dutch Copyright Act, indicated by the “Taverne” license above, please follow below link for the End User Agreement:

www.tue.nl/taverne Take down policy

If you believe that this document breaches copyright please contact us at: openaccess@tue.nl

providing details and we will investigate your claim.

(2)

Direct Sample Introduction of High Boiling Compounds Onto Glass Capillary Columns. Comparison of

Manual and Automatic Sampling

C. A. Cramers / E. A. Vermeer

Department of Instrumental Analysis, Eindhoven University of Technology, Eindhoven, The Netherlands

Summary

The performances of two systems for the direct intro- duction o f high boiling compounds onto glass capillary columns are compared. Samples investigated consisted o f hydrocarbons and steroids. The "Moving Needle" system (a manual version) developed in our laboratory is exten- sively described in the fiterature [1]. The standard deviation for quantitative measurements is approximately 2.5 % teL Recently a Pye A u t o Solids Injector has been modified so as to meet the requirements set by capillary gas chromato- graphy. The very large dead volume o f this sampling system, due to the use o f sample holders prevents the direct coupling o f this system to a capillary column. After introduction of a sample holder the solid sample evaporates slowly and the sample compounds are spread throughout a large volume of carrier gas, this badly affects the resolution obtainable. To overcome this problem the oven of the chromatograph contains a capillary pro- column (of some 50 cm length), which during a short period after sample introduction is cooled by a f l o w o f air. During this cooling period the sample compounds are effectively trapped in the pre-column. A f t e r one minute the cooling medium is turned off, the pre-column rapidly heats in the column oven and a sharp reinjection o f the sample occurs. A complete description of the system is given. The repeatability o f quantitative measurements (Orel)

isbetter than 1.5 %. There is no loss of resolution by using this sampling technique. Both systems described are com- patible with isothermal and programmed operation. Also in both versions the solvent does not enter the capillary column to an appreciable extent.

Introduction

The high resolving power of capillary columns can only be exploited fully if quantitative sample introduction systems

are developed. For many biochemical applications the

use of stream splitters is prohibitive because of sample size requirements and nonlinearity of the splitting pro- cedure for high boiling compounds. Several systems of direct sample introduction have been proposed [ 1-5].

Van den Berg of our laboratory [ 1] described an all glass "Moving Needle" system for the direct introduction of high boiling compounds onto capillary columns. With this

system the standard deviation, orel, for quantitative measurements was less than 2.7 % (for steroids and hydro- carbons).

Due to the very small dead volume of above-mentioned system the resolution of capillary columns is not affected. Because of a demand for faster and more accurate analyses of an increasing number of samples automation of ana-

lytical methods is necessary. However, Van den Berg's

design does not lend itself to automation. Therefore, it was decided to adapt a Pye Auto Solids Injector to meet the requirements of capillary gas chromatography. The principle of trapping and reinjection was used as already described by one of the authors [2] for volatile

samples (manual method), Rushneck [3] and Grob [4, 5].

Description of the Adaptation of the Pye-Unicam Auto Solids Injector for Use with Glass Capillary Columns.

The system was originally designed for the analysis of up to 35 solid samples on packed columns. It utilizes small, open ended, glass cylinders as sample holders into which solutions of the samples in a volatile solvent are intoduced after which the solvent is evaporated. After loading, the magazine with the sample holders is transferred to the injection system fitted to the chromatograph (See Fig. 1). Forward movement of the actuator(4) pushes the bottom sample holder in the magazine forward so that it drops into the position above the top of the column. Here the solid sample vaporizes and enters the column. The very large dead volume of this system prohibits its use with capillary columns. The sample components are spread throughout a large volume of carrier gas, this minimizes the resolution obtainable. To overcome this problem the oven of the chromatograph contains a capillary pro-column (length 50 cm, inside diameter 0.25 mm coated with SE-30), which during a selected period after sample introduction is cooled by a flow of air (from 240 ~ to about 140 ~ During this cooling period the sample components are effectively trapped in the pre-column. Usually after one minute, the cooling is stopped, then the precolumn rapidly heats and a sharp reinjection of the sample occurs.

At the same time solenoid 6 is energized and ejects the empty sample holder into the reservoir mounted on the chromatograph.

Then the injection actuator (4) is forced backwards thus allowing the next sample holder to position for injection.

(3)

The sequence of events described above (including the actuating of a magnetic valve for the air cooling) is con- trolled from a cam timer fitted to the control unit of the Auto Solids Injector.

The connections ( o f very small dead volume) between the solid injector, pre-column, column and detector are made with teflon shrinking tubing.

In the version described (air as the cooling medium) and minimum temperature of the precolumn 140 ~ it should only be used for components less volatile than

n-C20. In the Auto Solids Injection System the samples are kept under nitrogen (carrier gas) to avoid decomposi- tion by contact with air. Also storage for longer periods prohibits the use of more volatile samples. The system with glass sample holders provides a convenient means of sample concentration when dealing with dilute solutions of involatiles in volatile solvents.

Chromatographic Conditions

The gas chromatograph used was a Pye Unicam Model 104 equipped with both the Auto Solids Injector and the all

glass sampling system as described by Van den Berg [1].

Flame ionisation detection was used in all experiments. For the evaluation of both sampling devices a glass capillary column, 15 m • 0.25 m m coated with SE-30 was used. The column temperature was kept at 240 ~ during all experiments. The injection region of the Auto Injector (near item 5 in Fig. 1) was maintained at 270 ~

Fig. 1

Adaptation of Pye Auto Solids Injector for direct sample introduc- tion of high boiling compounds onto glass capillary columns. (1) sinter bleed, (2) magazine, (3) sample holders, (4) inject actuator, (5) injection heater, (6) eject actuator, (7) air flow, (8) capillary pre-column, (9) FID.

The standard mixtures of hydrocarbons and TMS-deriva. tives of steroids, as introduced onto the column, contain~ approximately 50 ng per component.

! C 24 ~HEA Ell 2~

Ll_

o $ I o Is ~r Fig. 2 . . . .

Chromatogram of some steroids and hydrocarbons. Using adapted Auto Injector (approximately 50 ng per component)

Column: 15 m X 0.25 mm; SE-30.

1 = n-C22 2 = n-C24 3 = DHEA = dehydroepian&~

sterone

4 -'- PN = pregnanolone 5 = Eli --- estradiol 7 = n-C28

8 = EIII = estriol 9 = n-C30

Comparison of the Manual and Automatic Sampling Systems. ("Moving Needle" versus adapted Pye Solid- Sampler).

The same standard mixture of steroids (TMS-derivatives) and hydrocarbons was used in all experiments to avoid differences in composition due to, for example, derivative formation. The remaining solvent peak originates from the reagents used for derivative formation.

a. Qualitative Analysis

Retention indices for steroids obtained with both systems are in agreement within 1.5 index units. (Standard devi- ation on both systems 1.5 index units). No significant differences are observed.

b. Resolution

No significant differences in peak width at h~df height are found using both sample introduction systems. As pointed out already in reference [ 1] the loss in resolving power due to the sampling procedure calculated for n-C28 is smaller than 1% for the manual version. The peak shape is better using the automatic sample introduction (less tailing).

(4)

Table I.

"Moving Needle" Automatic Injector Compound Composition Mean of Mean of Orel % ffrel % % w/w 15 runs 15 runs n-C20 .16.6 17.8 2.7 16.3 1.4 n-C22 22.2 22.2 2.3 22.2 1.5 n-C24 28.0 28.0 2.4 28.6 1.1 n-C28 33.2 32.0 1.9 32.9 1.2 Table H.

Compound "Moving Needle" Automatic Injector

Mean of Mean of

15 runs Orei% 15 runs Orel %

DHEA = Dehydroepi- 11.6 2.9 11.4 1.8 androsterone PN = Pregnanolone 22.8 2.3 22.1 1.3 Ell = Estradiol 14.8 2.6 14.8 1.8 PD = Pregnanediol 25.7 2.8 25.4 1.5 EIII = Estriol 25.1 3.1 26.3 1.2 c. Quantitative A t m l y s i s

The repeatability and reproducibility o f the Auto Injector and the manual system were tested on the basis o f peak areas (Infotronics type CRS-208). Table I shows the results obtained from 15 runs of n-alkanes (about 50 ng per com- ponent).

The performance o f b o t h systems was also tested with TMS derivatives o f steroids (see Table II).

Here also about 50 ng per c o m p o n e n t was introduced. The number of runs for steroids was also 15. Uncertainties in flame factors as well in completeness of derivative formation made the use o f calibration samples o f k n o w n quantitative composition impossible.

Conclusions

Apart from the obvious advantage o f automatic analysis, the adapted version o f the Pye A u t o Solids Injector should be preferred because o f better peak shape and better re- peatability and reproducibility.

Both systems are compatible with isothermal and pro- grammed analysis and the solvent does n o t enter the capil- lary column to an appreciable extent.

References

[ 1 ] Van den Berg, P. M. J. and Cox, Th., Chromatographia 5, 301 (1972).

121 Cramers, C. A. and van Kessel, M. M., J. Gas Chromatog. 6 (1968).

[31 Rushneck, D. R., J. Gas Chromatog. 3,318 (1965). 141 Grob, K. and Grob, G., J. Chromatog. Sci. 7, 584 (1969). I51 (7,rob, K. and Grob, G., ]. Chromatog. Sci. "I, 587 (1969).

Referenties

GERELATEERDE DOCUMENTEN

1997: Antwerpen, gezamenlijke wetenschappelijke dag met de BVP, tevens 20- jarig bestaanviering van

was, had Maulnier toen al ruimschoots getoond, door zich - ondanks alle beledigingen aan zijn adres in Les décombres - in te zetten voor het gratieverzoek dat het doodvonnis

This led to the research question of how three important political parties in South Africa, namely the African National Congress (ANC), the Democratic Alliance (DA) and the

It is then argued that insights from the Christology of John Calvin provide avenues for restoring human dignity in Africa, and that his work on the threefold office of Christ

Although all 3 thawed embryos were intact at transfer, blastomeres of embryos are often damaged after thawing.. There are, however, no indications that abnormalities increase

De be- schikbaarheid van deze eiwitten biedt perspectieven voor screening van planten op botrytis resistentie zonder dat daarbij gebruik hoeft te worden gemaakt van ziektetoetsen..

Natuurdoeltype Hz-3.14 bosgemeenschappen van leemgrond Hz-3.18 boombos Hz-3.19 park-stinzenbos Ri-3.9 bosgemeenschappen van zandgrond Lv-3.2 brak watergemeenschap Zk-3.2

Voor het beantwoorden van deze vraag is het belangrijk te weten waar Erwinia in het milieu voorkomt, en hoe lang deze bac- terie in het milieu kan overleven.. Met deze kennis