• No results found

Large-area pulsed laser deposition and assembly processes for pierzoelectric MEMS devices based on all-oxide LaNiO3/Pb(Zr,Ti)O3/LaNiO3 thin films

N/A
N/A
Protected

Academic year: 2021

Share "Large-area pulsed laser deposition and assembly processes for pierzoelectric MEMS devices based on all-oxide LaNiO3/Pb(Zr,Ti)O3/LaNiO3 thin films"

Copied!
1
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

Large-area Pulsed Laser Deposition and Assembly Processes for Piezoelectric MEMS Devices Based on All-oxide LaNiO3/Pb(Zr,Ti)O3/LaNiO3 Thin-films

Minh NGUYEN1#+, Matthijn DEKKERS1, Maarten VAN JALK1, Joska BROEKMAAT1, Arjen JANSSENS1, Hammad NAZEER2, Dave BLANK3, Guus RIJNDERS3

1SolMateS B.V., Netherlands, 2Transducers Science and Technology, MESA Institute for Nanotechnology, University of Twente, Netherlands, 3Inorganic Materials Science, MESA Institute

for Nanotechnology, University of Twente, Netherlands #Corresponding author: minh.nguyen@solmates.nl +Presenter

This research presents the fabrication of all-oxide LaNiO3/Pb(Zr,Ti)O3/LaNiO3 thin films for applications in piezoelectric microelectromechanical systems (piezoMEMS). All oxide layers are fabricated on 4-inch silicon-on-insulator (SOI) wafer using large-area pulsed laser deposition (PLD) by SolMateS B.V. The determined film-thickness variation is less than 5% over the total wafer area. PZT thin-film of 1-µm-thick exhibits (100) texture orientation.

The optimization of the electromechanical responses for piezoelectric membranes is investigated experimentally. In the optimization of membrane- and electrode-geometries, Pb(Zr,Ti)O3 (PZT) actuators consisting of a variety of membrane type, membrane diameter and electrode coverage are fabricated using microfabrication processes and characterized by laser Doppler interferometer for piezoelectric responses, like displacement and resonance frequency.

The fabricated 500-µm-diameter PZT membrane provides high central displacement of 26 nm/V at a constant frequency well below its first resonance frequency (fr= 330 kHz). The results also indicated that the membrane diameter has a dominant effect on the magnitude of the out-of-plane displacement and the resonance frequency. The electrode-size to membrane-diameter ratio or electrode coverage is important and may be tailored to optimize the displacement. Electrode coverage of 36% produces the optimum displacement. Moreover, it shows an excellent long-term stability of membrane actuators with a displacement remains of about 95% after 10 billion actuations, by using the conductive-oxide LaNiO3 (LNO) layers as the electrodes.

Page 1 of 1 Untitled Document

30-1-2012 http://www.meetmatt-conf.net/icmat2011pub/absView.asp?absId=1890

Referenties

GERELATEERDE DOCUMENTEN

This study focused on the ability of mebendazole to incorporate solvent molecules into its crystal lattice, and on the thermodynamic stability of these

Bovendien zouden ombudsmannen niet onafhankelijk genoeg opereren omdat ze in dienst zijn van de krant (Ettema & Glasser 1987), en hebben ze zich de rolpercepties van

By seeking counsel from the former resistance, the process of transitional justice and the Special Administration of Justice gained legitimacy from the general population, even

A comparative study between the Gulag memoirs from the Khrushchev period and those written in the late Soviet period would be insightful regarding the way

15 presidential elections, an outsider is (1) a candidate who does not have any previous political experience at the time of the electoral campaign and (2)

In accordance with the related literature, my expectation is that share repurchase announcements will be followed by positive cumulative abnormal returns explained

Retrospectieve follow-up van patiënten met psoriasis behan- deld door dermatologen of met PsA behandeld door reumato- logen.. Patiënten die tussen 2006 en 2012 begonnen met (MTX)