Presentation Abstract

Program#/Poster#: 413.15/OOO57

Title: 12-segment cuff is superior to ring cuff for sensing and stimulation of cardiac fibers in the vagal trunk

Location: Halls B-H

Presentation

Time: Monday, Nov 15, 2010, 10:00 AM -11:00 AM

Authors: *S. C. ORDELMAN1, L. KORNET2, R. CORNELUSSEN2, H. P. J.

BUSCHMAN3, P. H. VELTINK1;

1MIRA Inst. for Biomed. Technol. and Tech. Med., Univ. of Twente,

Enschede, Netherlands; 2Medtronic, Maastricht, Netherlands;

3Medtronic, Heerlen, Netherlands

Abstract:

Introduction The vagal nerve is involved in reflexive control of the

heart. We would like to sense vagal activity originating from cardiac sensory neurons, and influence cardiac parameters by electrical stimulation of the vagal nerve. The ability of the 12-segment cuff to influence and sense cardiac fibers in the vagal trunk will be compared with the ring cuff.

Methods Experiments were performed in twelve pigs. At the cervical

level three cuff electrode configurations were placed on the left vagal nerve for recording and stimulation. The cuffs were 15 mm long and had three circular Pt/Ir electrode contacts with (Fig. 1b). In seven pigs, the third cuff was replaced with a cuff with 12 segments instead of three rings (Fig. 1a). ECG and left ventricular pressure were also recorded.

Sensing In twelve pigs sensing was done with a ring cuff and in seven

also with a 12-segment cuff. ENG was band-pass filtered at 100-2000Hz, rectified and low-pass filtered at 10Hz, resulting in the envelope of the ENG. Mean activity was removed to obtain only the variations within a cardiac cycle. An ensemble average was determined

(2)

7-9-2018 Abstract Print View

http://www.abstractsonline.com/Plan/AbstractPrintView.aspx?mID=2554&sKey=f3453a46-1cfe-4e64-bda9-b41b4b092a77&cKey=fb341490-42d2-… 2/2

from 260 cycles of ENG signal, centered on R-tops of the ECG. A signal was identified as cardiac-modulated if the 95%-CI of the ensemble average had a deviation from zero. Stimulation In five pigs the maximal amplitude (300µs, 50Hz) was determined at which, during stimulation with the ring electrode, no coughing occurred. Next in these five pigs, stimulation with this setting was repeated with the ring cuff and the 12-segment cuff.

Results A significantly cardiac-modulated vagal signal was measured in

6/7 pigs with the 12-segment cuff and in 6/12 pigs with the ring cuff. The effect of electrical stimulation on left ventricular pressure was significantly greater when stimulating with the 12-segment cuff than with the ring cuff (p = 0.03). A significant difference was not reached for R-R (p = 0.2) and left ventricular contractility (p = 0.07).

Conclusion The 12-segment cuff seems superior to the ring cuff,

considering selective sensing and stimulation of the cardiac fibers in the cervical vagal trunk.

Disclosures: S.C. Ordelman: None. L. Kornet: Employment; Medtronic. R.

Cornelussen: Employment; Medtronic. H.P.J. Buschman:

Employment; Medtronic. P.H. Veltink: None.

Keyword(s): MULTIELECTRODE

VAGUS

ELECTRICAL STIMULATION

Support: Medtronic

[Authors]. [Abstract Title]. Program No. XXX.XX. 2010 Neuroscience Meeting Planner. San Diego, CA: Society for Neuroscience, 2010. Online.

2010 Copyright by the Society for Neuroscience all rights reserved. Permission to republish any abstract or part of any abstract in any form must be obtained in writing by SfN office prior to publication.

Referenties

GERELATEERDE DOCUMENTEN

Future ERP research might join efforts to draw conclusions using specific tasks required to detect the brain stimulation effects of taVNS, following up on our data and that of

ACE ¼ angiotensin-converting enzyme; CAD ¼ coronary artery disease; DCM ¼ dilated cardiomyopathy; EPS ¼ electrophysiological study; HF ¼ heart failure; ICD ¼ implantable

(1983:478) in hulle navorsing oor verskillende uitbrandingsmodelle bevind dat die komponente van emosionele uitputting, depersonalisasie en 'n afname in

Volledige pulmonaalvene isolatie (door ofwel segmentale ostium ablatie, danwel circumferentiële ablatie) is een effectievere behandelmethode voor boezemfibrilleren

On-line acquisition of anatomical information regarding left atrial and pulmonary vein anatomy can also be obtained by intracardiac echocardiography (ICE) 7 8. Advantages of

Climate change has severe consequences for natural and social systems worldwide, and small island developing states (SIDS) are often indicated as one of the most vulnerable regions

We propose that the best biotechnological solution for reducing the need for phosphorus fertilizer in Dutch maize production will consist of a combination of increasing

Business management Marketing communication management Communication management Characteristics of IC Two-way communication Manage relationships Increase brand