• No results found

Measuring Physiological Nociceptive and Tactile Steady-state Evoked Potentials

N/A
N/A
Protected

Academic year: 2021

Share "Measuring Physiological Nociceptive and Tactile Steady-state Evoked Potentials"

Copied!
1
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

Discussion

Stimulation Artefacts

 Visibly present in some subjects.

 How to distinguish between stimulus artefacts and physiological components?

Independent Component Selection

 Various possible measures of SNR.

 Components not selected consistently among subjects.  How to reliably select physiological components?

Optimal Stimulus Sequence for SI

 Sine FM: Only 3rd harmonic and higher in response.  Pulse FM: Power distributed over harmonics.

 Square FM: Power distributed over harmonics with preference for 3rd.

B. van den Berg, M. Manoochehri and J.R. Buitenweg

Biomedical Signals and Systems Group, University of Twente

Introduction

One in five adults suffer from chronic pain, which is the result of disturbed processes in the central nervous system.

 Early detection enables better treatments and less clinical efforts.  Disturbances are being studied using nociceptive detection

thresholds (NDTs) and evoked potentials (NEPs).

Steady-state evoked potentials are less susceptible to artifacts, and have a broader range of applications.

 Easily quantified and reproduced (Regan, 1982).

 Can reveal sensory integration (Colon et al., 2014).

 Harmonics and inter-modulation frequencies are useful for system identification (Yang et al., 2017).

Can we reliably elicit and measure nociceptive and tactile steady-state evoked potentials?

Method

Experiment

1. EEG in response to electric stimulus sequences via ECG (tactile) and IES5 (nociceptive) electrodes..

1. Frequency modulation using sine, pulse or square waves. 2. Sequences are applied in blocks to the subjects.

Analysis

1. Import continuous data 2. High-pass filter at 2 Hz

3. Notch filter at 50 Hz and harmonics 4. Data cleaning using ASR

5. Data re-referencing

6. Epoch from -2s to 10s for all sequence types 7. ICA using AMICA

8. Dipole fit

9. Separate epochs based on sequence type

First Results

Stimulation frequency and/or harmonics present in EEG.

 Frontal distribution of power in harmonic frequencies.  Harmonics decrease non-linearly over scalp.

 Harmonics up to 500 Hz.

SNR distribution dependent on SNR equation.

 SNR over entire spectrum shows a central distribution.

 SNR over harmonic frequencies shows central distribution.

Clustering shows some component clusters with harmonics.

 Physiological location and spectrum.

1

2

3

Nociceptive Tactile 𝑆𝑁𝑅 = σ 𝜇𝑓𝑓𝑡 𝑠𝑖𝑔𝑛𝑎𝑙(𝑓) σ 𝜇𝑓𝑓𝑡 𝑏𝑎𝑠𝑒𝑙𝑖𝑛𝑒(𝑓) 𝑆𝑁𝑅 = σℎ𝑎𝑟𝑚.𝜇𝑓𝑓𝑡 𝑠𝑖𝑔𝑛𝑎𝑙(𝑓) σℎ𝑎𝑟𝑚.𝑉𝐴𝑅𝑓𝑓𝑡 𝑠𝑖𝑔𝑛𝑎𝑙(𝑓) 𝑆𝑁𝑅 = σ 𝜇𝑓𝑓𝑡 𝑠𝑖𝑔𝑛𝑎𝑙(𝑓) σ 𝑉𝐴𝑅𝑓𝑓𝑡 𝑠𝑖𝑔𝑛𝑎𝑙(𝑓) 𝑆𝑁𝑅 = σℎ𝑎𝑟𝑚.𝜇𝑓𝑓𝑡 𝑠𝑖𝑔𝑛𝑎𝑙(𝑓) σℎ𝑎𝑟𝑚. 𝜇𝑓𝑓𝑡 𝑏𝑎𝑠𝑒𝑙𝑖𝑛𝑒(𝑓)

Referenties

GERELATEERDE DOCUMENTEN

Peter Siebers (RvB ZIN) geeft aan dat het Zorginstituut zich meer gaat richten op onderwerpen die er maatschappelijk toe doen, en zich niet meer laat leiden door slechts wat hij

Based on artificially generated data with recorded CI artifacts and simulated neural responses, we conclude that template subtraction is a promising method for CI artifact

The third method, based on template subtraction, reliably suppresses CI artifacts in ipsi- and contralateral channels for high-rate stimulation at comfort level in monopolar

The estimated CI artifact exibits the same properties as the CI artifact obtained by blanking for measurements in bipolar mode: the artifact is time-locked to the stimulus pulse

For the 40 Hz MFTF dataset containing large EASSRs, ICA was capable of removing CI artifacts from all ipsilateral recording channels, without distorting the EASSR in the

In conclusion, our KF approach is able to estimate a linear model of neural re- sponse and stimulation artifact when using clinical stimulation parameters.. The advantages of KF

To make a qualitative comparison between the synchron- ous and asynchronous modes, the data recorded with the previous on-line typing method was also subjected to a

To make a qualitative comparison between the synchron- ous and asynchronous modes, the data recorded with the previous on-line typing method was also subjected to a