• No results found

Combining heart rate and accelerometer data to estimate physical fitness

N/A
N/A
Protected

Academic year: 2021

Share "Combining heart rate and accelerometer data to estimate physical fitness"

Copied!
1
0
0

Bezig met laden.... (Bekijk nu de volledige tekst)

Hele tekst

(1)

COMBINING HEART RATE AND ACCELEROMETER DATA TO ESTIMATE PHYSICAL FITNESS

T.M. Tönis*†‡, M.M.R. Vollenbroek-Hutten †‡, H.J. Hermens †‡ Roessingh Research and Development, Telemedicine group

University of Twente, Faculty of Electrical Engineering, Mathematics and Computer Science, Telemedicine group

Roessinghsbleekweg 33b, 7522 AH Enschede, The Netherlands e-mail: t.tonis@rrd.nl

Web page: www.rrd.nl ABSTRACT

Monitoring changes in physical fitness is relevant in many conditions and groups of patients, but its determination demands substantial effort from the person, personnel and equipment. Besides that, present (sub) maximal exercise tests give a momentary fitness score, which depends on many (external) factors. Obtaining a fitness score based on measures gathered during longer periods of time and in natural conditions, like in daily life, would be an attractive alternative for the present methods. We performed an explorative lab-experiment to study the feasibility of fitness estimation during an activity commonly encountered in daily life; walking.

PURPOSE: To investigate the feasibility of physical fitness estimation from combined heart rate and accelerometer data obtained during treadmill walking.

METHODS: Forty-one subjects (23m, 18f) aged between 21 and 29 walked at three speeds on a treadmill (4, 5.5 and 6 kmh-1) wearing a heart rate monitor and a hip mounted 3D accelerometer. The acceleration signal was converted into activity counts [1] per 10 seconds. Stepwise linear regression analysis to estimate VO2max was performed on the slope and

intercept of the linear relation between heart rate and activity counts during steady state exercise (> 3min), together with age, gender, weight, length and BMI. Reference VO2max was

obtained by performing a sub-maximal single stage treadmill walking test [2].

RESULTS: The model with the highest percentage of explained variance (R2=0.93) combined the slope and intercept parameter of the relation between heart rate and activity counts, together with gender. The model had a standard error of the estimate of 1.78 ml O2kg-1min-1.

DISCUSSION: Results of the model are comparable with commonly used submaximal laboratory tests to estimate VO2max. Fusing heart rate and accelerometer data during steady

state activities seems promising for ambulant estimation of VO2max and would not require the

subject to carry out a high performance test. The applicability of current method on a broader age group and in daily life is part of ongoing research.

This study is supported by Alpe d’HuZes, a foundation which is part of the Dutch Cancer Society (KWF Kankerbestrijding).

REFERENCES

[1] C.V. Bouten, W.P. Verboeket-van de Venne, K.R. Westerterp, M. Verduin, J.D. Janssen, “Daily physical activity assessment: comparison between movement registration and doubly labelled water”, J. Appl. Physiol., Vol. 81, pp. 1019-1026, (1996).

[2] C.B. Ebbeling, A. Ward, E.M. Puleo, J. Widrick, J.M. Rippe, “Development of a

single-stage submaximal treadmill walking test”, Med. Sci. Sports Exerc., Vol. 23, pp. 966-973, (1991).

Referenties

GERELATEERDE DOCUMENTEN

Embryogenese vanuit jonge stuifmeelkorrels (microsporen) biedt in principe die mogelijkheid. Bij microsporenembryogenese ontstaan planten uit jonge stuifmeelkorrels.

Inschrijven is heel eenvoudig: ga naar deze link en geef je naam en organisatie op, alsook aan welke sessies je verkiest deel te nemen!. Er mogen merdere deelnemers zijn

By characterizing aperture antennas with different physical parameters in terms of equivalent circuit models, transmission line theory can be used to design an antenna array with

Een kwart van de bedrijven neemt meer dan zes maatregelen We kunnen ook naar de cumula eve verdeling kijken, zoals we voor verschillende bedrijfsgroo eklasses en bedrijfstakken

The health and quality compliance of game carcasses (n = 295) intended for the South African export market and aspiring to comply with the strict hygiene requirements of the

Simultaneous in vitro measurement of intestinal tissue permeability and transepithelial electrical resistance (TEER) using Sweetana-Grass diffusion cells. Determination of

Uit eerder onderzoek blijkt dat de leerkracht-kindrelatie niet alleen het schools functioneren van kinderen beïnvloedt, maar dat de kwaliteit van deze relatie ook beïnvloed wordt

Keywords: South Africa, central bank communication, inflation expectations, consistent communication, monetary policy transmission mechanism, transparent monetary