EVA2’s function check plan

In document Thesis Report (pagina 54-59)

Appendix I Test Plan

1. EVA2’s function check plan

Aim

EVA2’s function check plan is designed to check if all the hardware can work properly.

Functionality to be tested

• Function of ADC modules.

• Function of DAC modules.

• Function of PowerIO modules.

• Function of the Power supply board.

Hypothesis

When using the EVA Checker board which is designed with a GUI to check the ADC, DAC, PowerIO modules, all the test results are satisfactory. For Power supply board, when turn on the EVA2 set up, all power supplies, including 12 V, -12V, -5V, VCC, 3V3, PVCC, are working.

Target group & Measuring tools 1. Target group

• ADC modules.

• DAC modules.

• PowerIO modules.

• Power supply board.

2. Measuring tools

• Multimeter.

• EVA Checker board.

• SMU Actions

1. Insert the EVA Checker board into motherboard.

2. Power on EVA setup.

3. Connect SMU with motherboard via Banana chassis.

4. Check if all the LEDs corresponding to each power supplies is lighted on.

5. Use multiplexer to check if each pins’ voltage is same as the corresponding power supplies.

6. Open EVA Checker software and run the tests below:

- ADC test:

4 1) Click the ‘ADC Test’ button.

2) Press the ‘Self-test’ button to make sure the ADC function board test tool works 3) Click the ‘1.25V ref test’ to start testing all 96 channels of ADC modules.

4) Click the ‘4V ref test’ to start testing all 96 channels of ADC modules.

5) Select one channel and the testing voltage, and then, click the ‘Test’ button to test the target channel.

6) Close the ADC test window.

- DAC test:

1) Click the ‘DAC Test’ button.

2) Press the ‘Self-test’ button and short circuit test.

3) Click the ‘1.25V ref test’ to start testing all 96 channels of DAC modules.

4) Click the ‘4V ref test’ to start testing all 96 channels of DAC modules.

5) Select one channel and the testing voltage, and then, click the ‘Test’ button to test the target channel.

6) Close the DAC test window.

- PowerIO test:

1) Click the ‘PowerIO Test button.

2) Click ‘Auto test’ button to start testing all 96 channels of PowerIO modules.

3) Close the PowerIO test window.

7. Check if all the results are correct.

8. Close the main window and end the test.

Average bandwidth of reactions

The average bandwidth of reactions presents the different potential results of the test and the corresponding possible causes of the problem are also depicted.

Table 1-1 EVA2 function checker plan's average bandwidth of reactions EVA2

function check

Action Bandwidth of reactions

Power supply

The situation of the LED

corresponding to 12V and the situation of the voltage measured by multiplexer

Situation 1 (Best Condition):

The LED is on and the measured voltage equals to 12V

Situation 2:

The LED is off, and the measured voltage is much lower than 12 V Possible causes:

Short circuit or some connectors voltage is lower than 12 V Possible causes:

5 are not plugged

in properly.

Short circuit or some

connectors are not plugged in properly.

The situation of the LED

corresponding to -12V and the situation of the voltage measured voltage equals to -12V

Situation 2:

The LED is off, and the measured voltage is much lower than- 12 V Possible causes:

Short circuit or some connectors are not plugged in properly. voltage is lower than -12 V Possible causes:

Short circuit or some

connectors are not plugged in properly.

The situation of the LED

corresponding to VCC and the situation of the voltage measured voltage equals to VCC

Situation 2:

The LED is off, and the measured voltage is much lower than VCC Possible causes:

Short circuit or some connectors are not plugged in properly. voltage is lower than VCC Possible causes:

Short circuit or some

connectors are not plugged in properly.

The situation of the LED

corresponding to -5V and the

situation of the voltage measured voltage equals to -5V

Situation 2:

The LED is off, and the measured voltage is much lower than -5V Possible causes:

Short circuit or some connectors are not plugged in properly. voltage is lower than -5V

Possible causes:

Short circuit or some

6 connectors are not plugged in properly.

The situation of the LED

corresponding to 3V3 and the situation of the voltage measured voltage equals to 3V3

Situation 2:

The LED is off, and the measured voltage is much lower than 3V3 Possible causes:

Short circuit or some connectors are not plugged in properly. voltage is lower than 3V3 Possible causes:

Short circuit or some

connectors are not plugged in properly.

The situation of the LED

corresponding to PVCC and the situation of the voltage measured voltage equals to PVCC

Situation 2:

The LED is off, and the measured voltage is much lower than PVCC Possible causes:

Short circuit or some connectors are not plugged in properly. voltage is lower than PVCC Possible causes:

Short circuit or some

connectors are not plugged in properly.

ADC modules

The situation of

‘Auto test’ and

‘1.25V test’ and

‘4V test’

Situation 1 (Best Condition):

The results of all channels are green (pass)

Situation 2 (Best Condition):

The results of some or all channels are red (failed)

Possible causes:

Short circuit of the ADC modules;

Short circuit of the DAC

7 modules (SPI to

I2C bridge);

The situation of

‘Auto test’ and

‘1.25V test’ and

‘4V test’

Situation 1 (Best Condition):

The results of all channels are green (pass)

Situation 2 (Best Condition):

The results of some or all channels are red (failed)

Possible causes:

Short circuit of the DAC

modules (SPI to I2C bridge) or

The situation of

‘Auto test’

Situation 1 (Best Condition):

The results of all channels are green (pass)

Situation 2 (Best Condition):

The results of some or all channels are red (failed)

Possible causes:

Short circuit of the PowerIO

8 Predicted conclusions

• If all the reactions are Situation 1, then the EVA2 setup is suitable for doing EVA2 calibration test.

• If the reactions are mixed with Situation 1 and 2 (and 3) or are all Situation 2 or 3, then the EVA2 setup does not reach the standards.

In document Thesis Report (pagina 54-59)